{"product_id":"sick-cks36-pfbprogr-1035370","title":"SICK CKS36-PFBPROGR 1035370 Programmable Commutation Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for CKS36 feedback diagnosis and installation checks, and send-in evaluation where the fitted device and test setup are confirmed.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"SICK CKS36-PFBPROGR 1035370 Programmable Commutation Encoder technical guide\"\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the feedback label, complete motor or machine order, drive model and alarm. Include both connector faces and note whether the issue followed a cable change, replacement or mechanical work.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Mitchell describes electronic alignment through the direct lead on CKS units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Exact motor run setup open\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eSICK CKS36-PFBPROGR 1035370 Programmable Commutation Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full fitted label. A motor order identifies the assembly and should be recorded separately from an encoder part number.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eIdentification and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCKS36-PFBPROGR\u003c\/th\u003e\n\u003ctd\u003eProgrammable incremental feedback with commutation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1035370\u003c\/th\u003e\n\u003ctd\u003eExact SICK item with axial 20-pin male connector and tapered shaft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm current orderability and any successor for the exact ID with the manufacturer or motor OEM. The dated documentation identifies the configuration.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data for CKS36-PFBPROGR\" tabindex=\"0\"\u003e\u003ctable\u003e\n\u003ccaption\u003eReference data for CKS36-PFBPROGR\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEncoder supply\u003c\/th\u003e\n\u003ctd\u003e4.5–5.5 V DC on SICK item 1035370.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePublished setting\u003c\/th\u003e\n\u003ctd\u003e2,048 lines per revolution in the exact datasheet. Verify the programmed value on the fitted device.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCommutation setting\u003c\/th\u003e\n\u003ctd\u003eAdjustable from 1 to 32 pole pairs in the SICK sheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFit\u003c\/th\u003e\n\u003ctd\u003eTapered shaft and spring mounting plate. Use the exact attachment drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe SICK attachment drawing shows the taper, securing thread and spring plate. The mounting plate and screws must be correctly seated before an alignment check. Match the OEM hardware and assembly procedure rather than using a generic CKS mounting assumption.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eDifferential incremental channels report motion and the reference pulse. The programmed commutation pattern tracks the motor’s electrical cycle. Correct incremental counts can coexist with the wrong pole count or commutation reference.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eUse the exact SICK 20-pin connector view and the CKS36 product information for signal assignments. Verify plug orientation and configured count before making an adapter. Connector and accessory options shown for other feedback products require their own drawings.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eTI-5720 is the documented direct electronic alignment lead for supported CKS configurations. Confirm the exact pinout and mating fixture before connecting it. The installed motor loom is identified separately.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBefore inspection.\u003c\/strong\u003e Follow the site’s isolation and lockout procedure. Secure any load against movement, allow the specified discharge time and have a qualified technician verify isolation. Check resistance on a disconnected harness at both ends. Use the documented shield and return connections.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEncoder counts correctly but torque is irregular\u003c\/th\u003e\n\u003ctd\u003eReview pole pairs and electrical reference before replacing the encoder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReference pulse missing with A\/B intact\u003c\/th\u003e\n\u003ctd\u003eCheck the programmed reference width and gating, then compare the Z pair at the receiver.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault appears after mechanical replacement\u003c\/th\u003e\n\u003ctd\u003eCheck the taper and mounting plate seating before repeating electronic alignment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eMatch the installed motor and its pole count. Check the exact ID, drive and connector before applying an installation or test procedure.\u003c\/p\u003e\n\u003cp\u003eDistinguish correct counting from incorrect commutation. Check the fitted connector, programmed count and motor poles before service.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eRecord the original electrical angle, actual motor pole count and phase reference. Mitchell’s electronic reset procedure uses a motor-specific zero electrical reference and is intended for a secured service bench. Validate count, direction and commutation before running the motor.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26208240386715-Electronic-Alignment-of-SICK-Stegmann-CKS-Encoders-Using-the-TI-5720-Test-Cable\"\u003eCKS electronic alignment\u003c\/a\u003e. General Description and Operation. CKS and TI-5720.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/0\/40\/840\/dataSheet_CKS36-PFBPROGR_1035370_en.pdf\"\u003eSICK 1035370 datasheet\u003c\/a\u003e. Exact item ratings, connector view and attachment drawings.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/docs\/6\/56\/856\/product_information_cks36_motor_feedback_system_rotary_incremental_with_commutation_en_im0015856.pdf\"\u003eSICK CKS36 product information\u003c\/a\u003e. Series settings, electrical connections and installation context.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51127089791141,"sku":"TCG171","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/sick-cks36-pfbprogr-1035370-service-guide.jpg?v=1794236176","url":"https:\/\/www.sparefaber.com\/products\/sick-cks36-pfbprogr-1035370","provider":"SpareFaber","version":"1.0","type":"link"}