{"product_id":"sick-kh53-khk53-axr00038-1030048","title":"SICK KH53 KHK53-AXR00038 1030048 SSI Linear Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for KH53 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"SICK KH53 KHK53-AXR00038 1030048 SSI Linear Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eUse a compatible SSI master or the machine diagnostics to compare the decoded position and status along known travel. Use the matching SICK parameter tool when service access is required. Verify exact Mitchell support and any bench measuring element fixture before testing.\u003c\/p\u003e\n\u003ch2\u003eSICK KH53 KHK53-AXR00038 1030048 SSI Linear Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eKHK53-AXR00038\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKHK53-AXR00038 · 1030048\u003c\/th\u003e\n\u003ctd\u003eKH53 head for up to 38 m, with fixed 1.5 m twelve-wire cable.\u003c\/td\u003e\n\u003ctd\u003e24-bit Gray SSI, separate RS-422 service interface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKHK53-AXU00038 · 1030051\u003c\/th\u003e\n\u003ctd\u003eRelated 38 m head with a 10 m fixed cable.\u003c\/td\u003e\n\u003ctd\u003eSSI. Compare the exact cable routing and device configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKHK53-AXB00038 · 1030052\u003c\/th\u003e\n\u003ctd\u003eSeparate M23 male 12-pin device connector build.\u003c\/td\u003e\n\u003ctd\u003eSSI. Use the connector-specific drawing rather than a flying-lead assumption.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKHK53-PXF00038 · 1036163\u003c\/th\u003e\n\u003ctd\u003eRelated 38 m PROFIBUS head with separate M12 connections.\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS. It needs a different interface and commissioning setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eSICK publishes the exact 1030048 sheet and KH53 ordering information. Confirm production and replacement options for this order with SICK.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for KHK53-AXR00038\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for KHK53-AXR00038\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition\u003c\/th\u003e\n\u003ctd\u003e0–38 m with correctly selected measuring elements. Resolution 0.1 mm, repeatability 0.3 mm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e10–32 V DC, listed current 250 mA and initialization time 2 s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e24-bit Gray SSI. RS-422 service lines are separate and parameter interface is off by default.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection\u003c\/th\u003e\n\u003ctd\u003e1.5 m factory fixed cable, twelve-wire classification in the data sheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFit and environment\u003c\/th\u003e\n\u003ctd\u003eUse the N and Y attachment geometry. IP66 and −20 to +60 °C operating range. Precision conditions in the sheet are tighter than the maximum position envelope.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/0\/90\/690\/dataSheet_KHK53-AXR00038_1030048_en.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eFit the head and coded measuring elements in the documented orientation and sequence. Use the 38 m system mounting gauge KHM53-XXX00038 (1030057) where prescribed. Align the brackets through full travel and keep magnetizable parts clear per the exact attachment drawing. Check element joins and the cable carrier where position faults repeat.\u003c\/p\u003e\n\u003cp\u003eThe exact sheet separates nominal geometry, operating tolerance and accuracy conditions. Use the system drawing for element lengths, start positions and permitted gaps.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe head senses the coded measuring elements along the route. The PLC clocks absolute Gray-coded position over SSI. The separate asynchronous RS-422 service path is used for configuration where enabled. A healthy service connection does not prove that the PLC is clocking or decoding the SSI word correctly.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eThe exact 1030048 PDF combines the SSI connector reference view and cable colours. Use the colour column below for the fixed cable. The numbered M23 view is for the connector form, so verify your actual harness and receiving side independently.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"1030048 factory cable functions\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003e1030048 factory cable functions\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePath\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFactory lead colour\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply \/ GND\u003c\/th\u003e\n\u003ctd\u003eRed \/ blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSSI Data+ \/ Data−\u003c\/th\u003e\n\u003ctd\u003eWhite \/ brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSSI Clock+ \/ Clock−\u003c\/th\u003e\n\u003ctd\u003eYellow \/ violet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-422 service Rx+ \/ Rx−\u003c\/th\u003e\n\u003ctd\u003eGrey \/ green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRS-422 service Tx+ \/ Tx−\u003c\/th\u003e\n\u003ctd\u003ePink \/ black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUnused\u003c\/th\u003e\n\u003ctd\u003eOrange is unassigned in the exact sheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eKeep the service pairs separate from SSI and follow SICK's shield and cable instructions.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe 1.5 m fixed lead belongs to 1030048. The 3 m, 5 m and 10 m factory leads are separate readhead orders 1030049, 1030050 and 1030051. The 1030052 M23 head needs its own mating cable. Match the machine terminal drawing and shielding before ordering an extension.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo SSI word\u003c\/th\u003e\n\u003ctd\u003eConfirm supply and initialization time, then check controller clock and both SSI pairs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWord valid but travel wrong\u003c\/th\u003e\n\u003ctd\u003eCheck Gray decoding, scaling and the measuring-element arrangement and order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFF FF FE hex at a repeatable position\u003c\/th\u003e\n\u003ctd\u003eSICK identifies this error when the head leaves the elements or the permitted traversing speed is exceeded. Check actual position, speed and geometry.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFault near an element joint\u003c\/th\u003e\n\u003ctd\u003eCheck the mounting gauge alignment, bracket movement, element sequence and nearby magnetic material.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse this guide for the exact 38 m SSI head and the matching KH53 measuring elements. SICK lists KHT53-XXX00038 (1030055) and KHU53-XXX00038 (1030056) in the system guide. Confirm the coded or configurable element type before installation.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eCheck the head-to-element position along travel and verify the prescribed measuring-element sequence. Record controller position and datum before removal. Validate the SSI word, direction and absolute reference after fitting. The adjustment is a linear measuring system setup.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/0\/90\/690\/dataSheet_KHK53-AXR00038_1030048_en.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/KH53\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/0\/90\/690\/dataSheet_KHK53-AXR00038_1030048_en.pdf#page=5\"\u003eSICK exact wiring and M23 reference view\u003c\/a\u003e. Use fixed lead colours for 1030048.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/docs\/0\/00\/600\/product_information_kh53_linear_encoders_en_im0011600.pdf\"\u003eSICK KH53 ordering and installation information\u003c\/a\u003e. Match the head, scale elements and mounting gauge.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/9\/89\/689\/dataSheet_KHK53-AXB00038_1030052_en.pdf\"\u003eSICK 1030052 M23 variant\u003c\/a\u003e. Separate head and connector configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51119421554853,"sku":"TCG111","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/sick-kh53-khk53-axr00038-1030048-service-guide.jpg?v=1794148642","url":"https:\/\/www.sparefaber.com\/products\/sick-kh53-khk53-axr00038-1030048","provider":"SpareFaber","version":"1.0","type":"link"}