{"product_id":"sick-sek52-hfa0-k02","title":"SICK SEK52 HIPERFACE Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for SEK52 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"SICK SEK52 HIPERFACE Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eCheck HIPERFACE serial communication, position and status with a matched reader. Compare both sin\/cos pairs under the documented supply and fixture conditions. Mitchell's HIPERFACE chapter covers general procedures. Confirm the exact SEK52 variant, profile and lead before using TI-5000JX or a complete-motor run setup.\u003c\/p\u003e\n\u003ch2\u003eSICK SEK52 HIPERFACE Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003e1037368\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1037368 · SEK52-HFA0-K02\u003c\/th\u003e\n\u003ctd\u003e12.7 mm tapered-shaft variant with the attachment pattern in the exact drawing.\u003c\/td\u003e\n\u003ctd\u003eSingleturn HIPERFACE, 16 sin\/cos periods and axial 8-pin connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1037369 · SEK52-H1A0-K02\u003c\/th\u003e\n\u003ctd\u003eHollow shaft with shoulder clamping.\u003c\/td\u003e\n\u003ctd\u003eRelated singleturn SEK52. Use its own mounting drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1037370 · SEK52-HNA0-K02\u003c\/th\u003e\n\u003ctd\u003eHollow shaft.\u003c\/td\u003e\n\u003ctd\u003eRelated singleturn SEK52. Match the shaft retention and loom.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eSICK support article KA-09965 records phase-out of SEK52\/SEL52 on 20 December 2017. It names SEK37\/SEL37 as an electrically compatible family with a different mounting interface. Confirm the motor maker's replacement plan. \u003ca href=\"https:\/\/support.sick.com\/sick-knowledgebase\/article\/?id=e5f3521c-b565-4c61-a282-81b17c9791e3\"\u003eSICK lifecycle note\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for 1037368\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for 1037368\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasuring principle\u003c\/th\u003e\n\u003ctd\u003eBearingless capacitive rotary feedback, singleturn.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition data\u003c\/th\u003e\n\u003ctd\u003e512 serial steps per revolution. 16 sine\/cosine periods per turn on the process channels.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e7–12 V DC, 8 V DC recommended. Under 50 mA without load.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpeed\u003c\/th\u003e\n\u003ctd\u003e12,000 rpm mechanical rating. SICK gives 6,000 rpm for reliable generation of the absolute position.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFit and environment\u003c\/th\u003e\n\u003ctd\u003e12.7 mm tapered shaft, axial 8-pin male connector, −40 to +115 °C operating range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMemory\u003c\/th\u003e\n\u003ctd\u003e1,792 bytes available. Confirm the OEM's data layout and approved access method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/0\/50\/750\/dataSheet_SEK52-HFA0-K02_1037368_en.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the drawing for 1037368, including the taper, axial seating, shaft fastening and permitted attachment patterns. The drawing calls out an M4 × 20 DIN 912 fastener. The motor bearings and mating surfaces establish the encoder geometry. Check seating and movement before changing alignment, and use the OEM assembly instruction for screw torque.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eHIPERFACE carries the absolute starting position and parameter traffic on a bidirectional RS-485 pair. The drive separately tracks two analog sin\/cos channels during motion. Compare each signal to its corresponding reference. Stable serial position with irregular sin\/cos points to the analog path or mechanical fit before a serial fault.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eThis map applies to the axial 8-pin encoder connector on 1037368. Read the contact numbers and orientation from the exact SICK connection figure. Wire colors below describe the cable connection, so match the installed OEM loom separately.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"SEK52 1037368 connector\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eSEK52 1037368 connector\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePin\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSignal\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDocumented color\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1\u003c\/th\u003e\n\u003ctd\u003eUs\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2\u003c\/th\u003e\n\u003ctd\u003eSIN\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e3\u003c\/th\u003e\n\u003ctd\u003eREFSIN\u003c\/td\u003e\n\u003ctd\u003eBrown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e4\u003c\/th\u003e\n\u003ctd\u003eCOS\u003c\/td\u003e\n\u003ctd\u003ePink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e5\u003c\/th\u003e\n\u003ctd\u003eREFCOS\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e6\u003c\/th\u003e\n\u003ctd\u003e0 V\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e7\u003c\/th\u003e\n\u003ctd\u003eData +\u003c\/td\u003e\n\u003ctd\u003eGray or yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e8\u003c\/th\u003e\n\u003ctd\u003eData −\u003c\/td\u003e\n\u003ctd\u003eGreen or purple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe encoder supply return is separate from the housing. Follow the motor and drive drawing for shield termination.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eSICK lists DOL-0J08-G0M2XB6 (2031086), an 8-pin female JST to open leads, nominal 0.2 m and unshielded, and LTG-2708-MW (6028361), shielded bulk cable. These are separate components. Obtain the complete internal lead and motor bulkhead pinout from the motor maker before fabricating a loom.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDrive reports no serial feedback\u003c\/th\u003e\n\u003ctd\u003eCheck the 7–12 V supply under the approved test conditions, connector seating and the Data pair end to end.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial position is stable but speed feedback is noisy\u003c\/th\u003e\n\u003ctd\u003eCompare SIN to REFSIN and COS to REFCOS, and check shaft seating, lead shielding and connector contamination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor faults after a feedback swap\u003c\/th\u003e\n\u003ctd\u003eVerify singleturn vs multiturn configuration and match the motor reference or approved memory image. Check fit before applying motion.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eSICK documents SEK52 for servo motors and feeder axes. Verify the exact motor, connector and drive option. The replacement-family note is useful for electrical matching, while the taper and housing still require an application-specific mechanical review.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eFirst seat the taper and secure the stator using the motor and SICK drawings. Establish the motor commutation reference with the OEM commissioning procedure. Capture any documented motor-specific memory or drive offset before removal. Restore it only with the approved process for the same motor and validate feedback direction and alignment.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/0\/50\/750\/dataSheet_SEK52-HFA0-K02_1037368_en.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.sick.com\/sick-knowledgebase\/article\/?id=e5f3521c-b565-4c61-a282-81b17c9791e3\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.sick.com\/_entity\/annotation\/67e3a690-b72c-f011-8c4d-7c1e52295e3f\"\u003eSEK\/SEL family catalogue\u003c\/a\u003e. Variant drawings and the 2031086 encoder-end lead.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/26697502947227-SICK-Stegmann-Hiperface-Serial-Encoders\"\u003eMitchell HIPERFACE chapter\u003c\/a\u003e. Class-level testing and setup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51118391328933,"sku":"TCG53","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/SICKSEK52HIPERFACEEncoder.jpg?v=1794142448","url":"https:\/\/www.sparefaber.com\/products\/sick-sek52-hfa0-k02","provider":"SpareFaber","version":"1.0","type":"link"}