{"product_id":"sick-stegmann-sek34-hfb0k02-1053402-hiperface-encoder","title":"SICK Stegmann SEK34-HFB0K02 Singleturn HIPERFACE Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eCheck the SICK item number alongside the model. 1053402 is the SEK34 singleturn encoder. 1053403 identifies the related SEL34 multiturn model and changes how the drive receives turn information.\u003c\/p\u003e\n\u003cp\u003eSpareFaber offers UAE on-site fault diagnosis, installation and alignment checks for the documented feedback. Send the fitted labels and alarm details to arrange a visit or a send-in evaluation.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"SICK Stegmann SEK34-HFB0K02 Singleturn HIPERFACE Encoder technical guide\"\u003e\n\u003csection id=\"mitchell-tests\"\u003e\u003ch2\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTI-5000JX bench.\u003c\/strong\u003e Check the singleturn serial profile and analogue channels on the fitted suffix.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTI-3000JX motor run.\u003c\/strong\u003e Verify the complete motor and supported setup before a run.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting lead.\u003c\/strong\u003e Verify the exact radial encoder connector and choose the compatible classic HIPERFACE fixture.\u003c\/p\u003e\u003c\/section\u003e\n\u003ch2\u003eSICK Stegmann SEK34-HFB0K02 Singleturn HIPERFACE Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eInternal and machine cables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eMotor applications\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#questions\"\u003eQuestions\u003c\/a\u003e · \u003ca href=\"#service\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eCompare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Model and application references\" tabindex=\"0\"\u003e\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eModel and application references\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eID or order\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eHow to identify it\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSEK34-HFB0K02 \/ 1053402\u003c\/th\u003e\n\u003ctd\u003eCapacitive singleturn HIPERFACE, tapered shaft, radial eight-contact plug.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSEL34-HFB0K02 \/ 1053403\u003c\/th\u003e\n\u003ctd\u003eRelated multiturn model. Check the complete encoder and motor order before any substitution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKollmorgen AKM GP\u003c\/th\u003e\n\u003ctd\u003eKollmorgen lists SEK34 on the documented AKM1 GP branch. Verify the fitted SICK and motor labels.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eConfirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Reference data and applicability\" tabindex=\"0\"\u003e\u003ctable id=\"spec-table\"\u003e\n\u003ccaption\u003eReference data and applicability\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVerified scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnalogue process data\u003c\/th\u003e\n\u003ctd\u003e16 sine\/cosine periods per revolution for 1053402.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEncoder supply\u003c\/th\u003e\n\u003ctd\u003e7–12 V DC. The SICK data sheet recommends 8 V DC and lists up to 50 mA.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical\u003c\/th\u003e\n\u003ctd\u003eTapered shaft and 33.8 mm nominal housing feature in the dimension drawing. Read the full tolerance and mating detail.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e−40 to +115 °C and IP20 for the built-on, connected and closed encoder as stated by SICK.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe encoder uses capacitive measurement. The RS-485 parameter channel and analogue movement signals serve different functions. Check both when identity is readable but position quality degrades.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eUse the 1053402 drawing for the tapered shaft, stator location and installed stack height. Check the locating and seating surfaces for contamination. Preserve the received reference and cable orientation before moving the encoder.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\u003ch2\u003eWiring and connector scope\u003c\/h2\u003e\n\u003cp\u003eThese assignments apply to the eight-contact plug-in face in the 1053402 data sheet. Use the illustrated keying. Confirm the motor bulkhead drawing separately.\u003c\/p\u003e\n\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Connection reference for the stated view\" tabindex=\"0\"\u003e\u003ctable id=\"wiring-table\"\u003e\n\u003ccaption\u003eConnection reference for the stated view\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eContact or circuit\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDocumented scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1 \/ 6\u003c\/th\u003e\n\u003ctd\u003eEncoder supply \/ ground.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2 \/ 3\u003c\/th\u003e\n\u003ctd\u003eSine \/ reference sine.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e4 \/ 5\u003c\/th\u003e\n\u003ctd\u003eCosine \/ reference cosine.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e7 \/ 8\u003c\/th\u003e\n\u003ctd\u003eRS-485 data +\/−.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\u003ch2\u003eInternal motor and machine cables\u003c\/h2\u003e\n\u003cp\u003eIdentify the short radial connector harness from the fitted motor build. Match the other end at the motor bulkhead and trace the drive cable separately. SICK lists connector accessories in its data sheet. Confirm the compatible finished loom with the motor maker.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003eUse the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat can I check on the machine?\u003c\/summary\u003e\u003cp\u003eDisconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.\u003c\/p\u003e\n\u003cp\u003eUse only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.\u003c\/p\u003e\u003c\/details\u003e\u003cdiv class=\"sf-table-scroll\" style=\"overflow-x:auto;contain:inline-size\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\u003ctable id=\"fault-table\"\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSymptom\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReads model but faults when moving\u003c\/th\u003e\n\u003ctd\u003eCheck both sine\/cosine paths and references at the approved breakout.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExpected turns are missing\u003c\/th\u003e\n\u003ctd\u003eRead the exact 1053402 or 1053403 label and compare the drive configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOffset changes after mounting\u003c\/th\u003e\n\u003ctd\u003eVerify taper seating and stator support against the fitted assembly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eRecord the incoming motor reference and any OEM motor data stored in HIPERFACE. Fit the taper and stator to the exact drawing, then have a specialist verify the actual motor’s alignment before reuse.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eKollmorgen AKM GC\/GP and other documented fitted cases\u003c\/p\u003e\n\u003cp\u003eMatch the exact singleturn part, taper and pin view, and compare with the SEL34 multiturn version.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/articles\/4409347607963-Kollmorgen-AKM-support\"\u003eKollmorgen AKM support\u003c\/a\u003e. Mitchell-linked AKM Feedback Description, GC and GP SEK34 rows\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/docs\/9\/09\/209\/product_information_sek34_sel34_motor_feedback_system_rotary_hiperface%C2%AE_en_im0044209.pdf\"\u003eSICK SEK34\/SEL34 product information, SEK34 item 1053402\u003c\/a\u003e. Manufacturer reference for the indicated motor or feedback option. Check the fitted revision.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/article_attachments\/5104769779867\"\u003eMitchell-linked AKM Feedback Description\u003c\/a\u003e. Reference for the fitted feedback or motor option.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/8\/48\/048\/dataSheet_SEK34-HFB0K02_1053402_en.pdf\"\u003eSICK SEK34-HFB0K02 item 1053402 data sheet\u003c\/a\u003e. Exact dimensions, ratings and radial eight-contact plug-in face.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003csection id=\"questions\"\u003e\u003ch2\u003eQuestions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I use a similar label as a replacement?\u003c\/summary\u003e\u003cp\u003eCompare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat information helps with a diagnosis?\u003c\/summary\u003e\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\u003c\/details\u003e\u003c\/section\u003e\n\u003csection id=\"service\"\u003e\u003ch2\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE visit or feedback evaluation\u003c\/a\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51133565960357,"sku":"TCG300","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/sick-stegmann-sek34-hfb0k02-1053402-hiperface-encoder-service-guide.jpg?v=1794291230","url":"https:\/\/www.sparefaber.com\/products\/sick-stegmann-sek34-hfb0k02-1053402-hiperface-encoder","provider":"SpareFaber","version":"1.0","type":"link"}