{"product_id":"sick-ttk70-hxa0-k02-1037434","title":"SICK TTK70-HXA0-K02 1037434 Linear HIPERFACE Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for TTK70 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"SICK TTK70-HXA0-K02 1037434 Linear HIPERFACE Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eShare the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA compatible HIPERFACE receiver or approved bench fixture can read status, position and the process channels with the matching tape. Verify exact linear head support, adapter, supply and profile before using a Mitchell tester. A rotary servo fixture has different mounting and reference requirements.\u003c\/p\u003e\n\u003ch2\u003eSICK TTK70-HXA0-K02 1037434 Linear HIPERFACE Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eTTK70-HXA0-K02\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTTK70-HXA0-K02 · 1037434\u003c\/th\u003e\n\u003ctd\u003eLinear readhead with male 8-pin M12 and separate magnetic tape.\u003c\/td\u003e\n\u003ctd\u003eHIPERFACE analogue and RS-485 data paths. Standard version.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTTK70-HXJ0-K02 · 1063567\u003c\/th\u003e\n\u003ctd\u003e0.5 m factory eight-wire cable instead of the M12 device connector.\u003c\/td\u003e\n\u003ctd\u003eSame HIPERFACE family. Check the exact cable map.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTTK70S-HXA0-K02 · 1099700\u003c\/th\u003e\n\u003ctd\u003eEight-pin M12 head in the safety variant family.\u003c\/td\u003e\n\u003ctd\u003eUse the exact safety device documentation and acceptance process.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTTK70-AXA0-K02 · 1038033\u003c\/th\u003e\n\u003ctd\u003eSeparate 12-pin M12 configuration.\u003c\/td\u003e\n\u003ctd\u003eSSI interface. Match the controller and connector map.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eSICK publishes an exact 1037434 data sheet and family ordering table. Confirm current production and any announced replacement with SICK.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for TTK70-HXA0-K02\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for TTK70-HXA0-K02\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003e7–12 V DC, 8 V recommended. Up to 65 mA without load. SICK separately lists approximately 100 mA during adjustment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection\u003c\/th\u003e\n\u003ctd\u003e8-pin M12 male for 1037434. Verify both connector ends from the drawings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRepeatability and accuracy\u003c\/th\u003e\n\u003ctd\u003eRepeatability less than 5 µm, system accuracy ±10 µm at +20 °C in the exact sheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReadhead and tape\u003c\/th\u003e\n\u003ctd\u003e70 mm head length per drawing. Tape ordered separately. SICK specifies tape length as measurement path plus 80 mm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eIP67 with mating plug inserted, −30 to +80 °C in operation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe values in this table apply to the reference build unless a row identifies another scope. \u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/3\/43\/343\/dataSheet_TTK70-HXA0-K02_1037434_en.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eMount the head and matching magnetic tape in the orientation shown on the SICK drawing. Account for the cover strip when measuring the gap. Check lateral offset and gap along the full usable travel with the prescribed gauge or installation method. Keep the tape flat and inspect for mechanical damage and ferrous debris. A fault at one physical point often tracks to the tape, head bracket or cable carrier.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eHIPERFACE uses a serial parameter channel and analogue process signals. The controller reads the head's absolute position and uses the analogue sine and cosine channels for fine movement between position reads. One path may work while the other fails. Inspect the serial status and both process tracks to separate wiring and mounting problems.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eThis table follows the 1037434 data sheet pins. Use the connector drawing for the encoder mating view. The manufacturer lists alternative wire colours on cable builds. Identify the contacts rather than relying on colour alone.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"TTK70-HXA0-K02 eight-contact connection\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eTTK70-HXA0-K02 eight-contact connection\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eContacts\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunctions\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1 \/ 2\u003c\/th\u003e\n\u003ctd\u003eREFSIN \/ +SIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e3 \/ 4\u003c\/th\u003e\n\u003ctd\u003eREFCOS \/ +COS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e5 \/ 6\u003c\/th\u003e\n\u003ctd\u003eData+ \/ Data−, RS-485 parameter channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e7 \/ 8\u003c\/th\u003e\n\u003ctd\u003eGND \/ US supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing\u003c\/th\u003e\n\u003ctd\u003eShield connection in the SICK assignment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eUse the compatible eight-contact M12 mating connector and a shielded four-pair loom to the approved receiver. SICK documents a separately ordered 0.5 m cabled readhead 1063567 and a 1 m cabled head 1068879. Those are readhead variants. Order any external extension by receiver end, length and motion rating. The TTK70 manual identifies the matching tape series and lengths.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo serial position\u003c\/th\u003e\n\u003ctd\u003eVerify the supply and RS-485 parameter pair. Read the SICK status code and compare with the cable test.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial works, process position is noisy\u003c\/th\u003e\n\u003ctd\u003eCheck each signal against its own reference. Check gap across travel and the mounting bracket.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatus 21h at one location\u003c\/th\u003e\n\u003ctd\u003eThe exact sheet identifies excessive tape distance. Inspect local gap, tape and head bracket.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNew head reads but machine position differs\u003c\/th\u003e\n\u003ctd\u003eCheck tape orientation, machine zero, direction and OEM configuration before motion.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse this guide for the standard 1037434 head and matching linear tape. The separately marked TTK70S has its own safety documentation. See the \u003ca href=\"\/products\/sick-srs50-hza0-s21-1037395\"\u003eSRS50 guide\u003c\/a\u003e for the separate rotary HIPERFACE application.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eSet head-to-tape geometry with the documented gauge and verify it through full travel. Establish the machine datum after mounting. Record any supported encoder memory and receiver parameters before replacement, then restore data only under the approved OEM procedure. The relevant mechanical adjustments are readhead geometry and datum.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/pdf\/3\/43\/343\/dataSheet_TTK70-HXA0-K02_1037434_en.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Start with the exact type or variant marked in the guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/TTK70\"\u003eManufacturer or exact product reference\u003c\/a\u003e. Use the order code and select the applicable downloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/docs\/4\/84\/184\/operating_instructions_ttk70_hiperface_motor_feedback_systems_linear_hiperface%C2%AE_de_en_im0069184.pdf\"\u003eSICK TTK70 HIPERFACE installation instructions\u003c\/a\u003e. Use the gap and cover-strip figures and the applicable electrical connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.sick.com\/media\/productoverview\/6\/66\/566\/productoverview_TTK70_g201566_en.pdf\"\u003eSICK TTK70 family ordering table\u003c\/a\u003e. Distinguishes M12, fixed cable, safety and SSI versions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51119408021669,"sku":"TCG105","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/sick-ttk70-hxa0-k02-1037434-service-guide.jpg?v=1794148308","url":"https:\/\/www.sparefaber.com\/products\/sick-ttk70-hxa0-k02-1037434","provider":"SpareFaber","version":"1.0","type":"link"}