{"product_id":"siemens_sm331_6es7331-7kf02-0ab0","title":"Siemens SM331, 6ES7331-7KF02-0AB0 Analog input module  AI8x12bit","description":"\u003cp\u003e\u003cimg\u003eSM331, 6ES7331-7KF02-0AB0 Analog input module  AI8x12bit; 6ES73317KF020AB0\u003cbr\u003eSM 331;\u003c\/p\u003e\n\u003cdiv class=\"title-container\"\u003e\n\u003ch1 class=\"title ng-star-inserted\"\u003e6ES7331-7KF02-0AB0\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"description short\"\u003eSM331, 8AI, 9\/12\/14Bit\u003c\/div\u003e\n\u003cdiv class=\"description long\"\u003e***spare part*** SIMATIC S7-300, analog input SM 331, isolated, 8 AI, resolution 9\/12\/14 bits, U\/I\/thermocouple\/resistor, alarm, diagnostics, 1x 20-pole removing\/inserting with active backplane bus\u003c\/div\u003e\n\u003cdiv class=\"description long\"\u003e\n\u003ch4 class=\"title product-detail-page-component-module-scss-module__SKXDoW__title\"\u003eSiemens PLC Expansion Module Analogue for use with S7-300 Series\u003c\/h4\u003e\n\u003cdiv class=\"product-detail-page-component-module-scss-module__SKXDoW__info product-detail-page-component-module-scss-module__SKXDoW__prod-info\"\u003e\u003cspan\u003e\u003cspan class=\"product-detail-page-component-module-scss-module__SKXDoW__prod-info-title\"\u003eRS Stock No.: \u003c\/span\u003e453-2545 \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-detail-page-component-module-scss-module__SKXDoW__info product-detail-page-component-module-scss-module__SKXDoW__prod-info\"\u003e\u003cspan\u003e\u003cspan class=\"product-detail-page-component-module-scss-module__SKXDoW__prod-info-title\"\u003eSiemens Part No.\u003c\/span\u003e: 6ES 7331-7KF02-0AB0\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-detail-page-component-module-scss-module__SKXDoW__info product-detail-page-component-module-scss-module__SKXDoW__prod-info\"\u003e\u003cspan\u003e\u003cspan class=\"product-detail-page-component-module-scss-module__SKXDoW__prod-info-title\"\u003eDistrelec Article No.: \u003c\/span\u003e30410631\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg\u003eAnalog input module SM 331; AI 8 x 12 bit;(6ES7331-7KF02-0AB0)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4 id=\"\"\u003eOrder number\u003c\/h4\u003e\n\u003cp class=\"default\"\u003e6ES7331-7KF02-0AB0\u003c\/p\u003e\n\u003ch4 id=\"\"\u003eProperties\u003c\/h4\u003e\n\u003cul class=\"bullet\"\u003e\n\u003cli class=\"bullet\"\u003e8 inputs in 4 channel groups\u003c\/li\u003e\n\u003cli class=\"bullet\"\u003eProgrammable measurement type at each channel group\n\u003cul class=\"line\"\u003e\n\u003cli class=\"line\"\u003e\n\u003cspan\u003e- \u003c\/span\u003eVoltage\u003c\/li\u003e\n\u003cli class=\"line\"\u003e\n\u003cspan\u003e- \u003c\/span\u003eCurrent\u003c\/li\u003e\n\u003cli class=\"line\"\u003e\n\u003cspan\u003e- \u003c\/span\u003eResistance\u003c\/li\u003e\n\u003cli class=\"line\"\u003e\n\u003cspan\u003e- \u003c\/span\u003eTemperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"bullet\"\u003eProgrammable resolution at each channel group (9\/12\/14 bits + sign)\u003c\/li\u003e\n\u003cli class=\"bullet\"\u003eAny measuring range selection per channel group\u003c\/li\u003e\n\u003cli class=\"bullet\"\u003eProgrammable diagnostics and diagnostic interrupt\u003c\/li\u003e\n\u003cli class=\"bullet\"\u003eProgrammable limit value monitoring for 2 channels\u003c\/li\u003e\n\u003cli class=\"bullet\"\u003eProgrammable hardware interrupt when limit is exceeded\u003c\/li\u003e\n\u003cli class=\"bullet\"\u003eElectrically isolated to CPU and load voltage (not for 2-wire transducers)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eResolution\u003c\/h4\u003e\n\u003cp class=\"default\"\u003eThe resolution of measured values is directly dependent of the selected integration time. In other words, the longer the integration time for an analog input channel, the higher the resolution of a measured value.\u003c\/p\u003e\n\u003ch4\u003eDiagnostics\u003c\/h4\u003e\n\u003cp class=\"default\"\u003eFor information on diagnostics messages at the \"group diagnostics\" parameter, refer to chapter Diagnostic messages of analog input modules\u003ci\u003e.\u003c\/i\u003e\u003c\/p\u003e\n\u003ch4\u003eHardware interrupts\u003c\/h4\u003e\n\u003cp class=\"default\"\u003eHardware interrupts for channel groups 0 and 1 can be programmed in\u003cspan\u003e \u003c\/span\u003e\u003ci\u003eSTEP 7\u003c\/i\u003e. However, set a hardware interrupt only for the first channel of a channel group, that is, either at channel 0, or at channel 2\u003c\/p\u003e\n\u003ch4 id=\"\"\u003eTerminal assignment\u003c\/h4\u003e\n\u003cp class=\"default\"\u003eThe diagrams below show various wiring options The input impedance depends on the setting of the measuring range module, see table\u003cspan\u003e \u003c\/span\u003e\u003ci\u003eMeasurement types and ranges\u003c\/i\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cimg\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":48169552478373,"sku":"PLC31","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/SM331_6ES7331-7KF02-0AB0AnaloginputmoduleAI8x12bit_4.jpg?v=1787231880","url":"https:\/\/www.sparefaber.com\/products\/siemens_sm331_6es7331-7kf02-0ab0","provider":"SpareFaber","version":"1.0","type":"link"}