{"product_id":"tamagawa-doublsyn-tsy7020","title":"Tamagawa Doublsyn TSY7020 4X Resolver - Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003eAngle faults on a Tamagawa TSY7020?\u003c\/strong\u003e SpareFaber can inspect the fitted resolver, lead routing, converter configuration and angle repeatability at your UAE site. For bench evaluation, send the paired rotor and stator details, motor documentation and the exact harness.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Tamagawa Doublsyn TSY7020 4X Resolver technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eProvide the complete sensor and motor identification, converter type, drawings and the fault or angle pattern. Photograph the original rotor\/stator orientation and connector before removal. Agree packing and intake for the matched components. Use the \u003ca href=\"#encoder-enquiry\"\u003eenquiry form\u003c\/a\u003e to share the details.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA compatible two-phase resolver-to-digital setup can check the specified excitation and compare both output channels across known shaft positions. Tamagawa documents a VRS mode on its AUA6800 VRDC and supplies evaluation hardware. Mitchell's generic resolver chapter is background. Direct TI-5000JX excitation and TI-3000JX run compatibility for this two-phase VRS model were not verified. \u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/rd_converter\/vrdc\/\"\u003eTamagawa VRS converter and evaluation hardware\u003c\/a\u003e · \u003ca href=\"https:\/\/support.mitchell-electronics.com\/hc\/en-us\/sections\/26370850277403-TI-5000JX-Training-Manual\"\u003eMitchell generic resolver background\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eTamagawa Doublsyn TSY7020 4X Resolver technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eRead \u003cstrong\u003eTSY7020\u003c\/strong\u003e and record any OEM suffix or drawing number. This is the smaller Tamagawa Doublsyn with two-phase excitation and two-phase output. Compare the stator and rotor as a matched set. A 4X marking on another resolver alone does not identify its connection method.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Tamagawa variable-reluctance resolver comparison\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eTamagawa variable-reluctance resolver comparison\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eModel\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeasuring construction\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical and electrical distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTSY7020\u003c\/th\u003e\n\u003ctd\u003eDoublsyn VRS, 4X, two-phase excitation and two-phase output\u003c\/td\u003e\n\u003ctd\u003eØ52 mm stator, Ø25 mm rotor, 45 Ω ±10% input impedance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTSY7030\u003c\/th\u003e\n\u003ctd\u003eDoublsyn VRS, 4X\u003c\/td\u003e\n\u003ctd\u003eØ101 mm stator, Ø45 mm rotor, 75 Ω ±10% input impedance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTSY1010N1114E227\u003c\/th\u003e\n\u003ctd\u003eSinglsyn 4X stator option\u003c\/td\u003e\n\u003ctd\u003eSeparate resolver family and parts. Use the Singlsyn drawing and converter selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/doublsyn\/\"\u003eTamagawa TSY7020 \/ TSY7030 specifications\u003c\/a\u003e · \u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/singlsyn\/tsy1010\/\"\u003eTamagawa TSY1010 options\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eTamagawa lists TSY7020 and TSY7030 in its Doublsyn lineup. Confirm the lifecycle and exact motor-specific ordering and service options with Tamagawa. \u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/doublsyn\/\"\u003eTamagawa current Doublsyn lineup\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"TSY7020 manufacturer lineup values\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eTSY7020 manufacturer lineup values\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue \/ scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement\u003c\/th\u003e\n\u003ctd\u003eVariable-reluctance resolver, VRS. Two excitation phases, two output phases and 4 electrical cycles per mechanical turn.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExcitation entry\u003c\/th\u003e\n\u003ctd\u003e3 V peak-to-peak at 10 kHz in the Tamagawa table. Use the specified drive waveform, load and exact circuit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTransformation ratio and input impedance\u003c\/th\u003e\n\u003ctd\u003e0.2 ±8% and 45 Ω ±10% for TSY7020 as published. These values are distinct from a DC resistance acceptance limit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStator \/ rotor dimensions\u003c\/th\u003e\n\u003ctd\u003eØ52 mm stator outer diameter, −0.04\/+0 mm. Ø25 mm rotor outer diameter, +0.018\/+0.048 mm. Both 4 mm thick.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating limits\u003c\/th\u003e\n\u003ctd\u003e−40 to +150 °C and 30,000 rpm maximum in the product lineup. Installed motor limits can be lower.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAngle accuracy entry\u003c\/th\u003e\n\u003ctd\u003eTamagawa lists ±7.5 arcmin maximum (width). Use the original definition and application conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/doublsyn\/\"\u003eTamagawa exact TSY7020 technical table\u003c\/a\u003e · \u003ca href=\"https:\/\/www.tamagawa-seiki.com\/assets\/img\/downloads\/pdf\/resolver-synchro\/Doublsyn.pdf\"\u003eTamagawa Doublsyn technical brochure (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe flat stationary stator and rotating rotor are integrated into the motor. Verify the motor drawing for rotor location and retention, concentricity, axial location and allowable air gap. The outer diameters identify parts and do not establish a running clearance. Preserve the original rotational reference, match the rotor and stator, and protect the coils and faces from impact and debris. Use the motor service procedure for fitting and torques. \u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/doublsyn\/\"\u003eTamagawa part dimensions\u003c\/a\u003e · \u003ca href=\"https:\/\/www.tamagawa-seiki.com\/assets\/img\/downloads\/pdf\/resolver-synchro\/Doublsyn.pdf\"\u003eDoublsyn construction brochure (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe converter supplies two excitation phases and recovers angle from two outputs in the VRS arrangement. With 4X, one electrical revolution corresponds to 90° of mechanical travel. The raw angle therefore repeats four times per shaft turn. The machine's converter and commissioning method determine how that periodic angle relates to motor poles and full-turn position. Tamagawa distinguishes VRS from other excitation\/output patterns in its VRDC documentation. \u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/rd_converter\/vrdc\/\"\u003eTamagawa VRDC resolver modes\u003c\/a\u003e · \u003ca href=\"https:\/\/www.tamagawa-seiki.com\/assets\/img\/downloads\/pdf\/resolver-synchro\/Doublsyn.pdf\"\u003eDoublsyn signal architecture (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the \u003cstrong\u003eTSY7020 motor-specific drawing\u003c\/strong\u003e to identify the phases and lead polarity. Tamagawa's public lineup confirms the signal groups below. Obtain the exact sensor and converter pin\/colour map before connecting. The AUA6800 IC pinout applies to the converter chip itself.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"TSY7020 electrical functions to verify\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eTSY7020 electrical functions to verify\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eCircuit\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRole\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExcitation phase 1 and 2\u003c\/th\u003e\n\u003ctd\u003eThe specified two-phase reference drive from the matching converter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput phase 1 and 2\u003c\/th\u003e\n\u003ctd\u003eAngle-dependent analog return signals into the matching converter inputs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShield and return arrangement\u003c\/th\u003e\n\u003ctd\u003eFollow the motor harness and converter drawings. Verify intentional bonds with the cable disconnected.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/doublsyn\/\"\u003eTamagawa VRS signal description\u003c\/a\u003e · \u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/rd_converter\/vrdc\/\"\u003eSeparate converter schematic and pin functions\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThe internal resolver lead and machine bulkhead are defined by the installed motor. No standard TSY7020-to-M23 cable order code was verified. Record the exact motor drawing, both connector identifiers, contact mapping and routing. Ask Tamagawa or the motor OEM for the appropriate loom. Preserve the paired conductors and shielding specified by the machine drawings. \u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/doublsyn\/\"\u003eTamagawa model identification and technical contact\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSecure the load and isolate motor, drive and excitation before disconnecting.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecord and inspect.\u003c\/strong\u003e Note where the angle jumps or an alarm occurs. Check rotor retention, stator alignment and connector seating, dirt or damaged leads under isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the detached harness.\u003c\/strong\u003e With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. With the correct winding schematic, a qualified technician can compare disconnected winding readings with the OEM data or an exact known-good unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck excitation and return.\u003c\/strong\u003e On an approved fixture, verify both excitation phases at the specified test points. Compare outputs at known angles with appropriate differential equipment and a matched converter. Keep winding impedance at 10 kHz separate from an ohmmeter reading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocalize.\u003c\/strong\u003e If excitation is missing, trace the converter and harness. If valid return is present at the sensor and missing at the converter, trace the loom. If the 4X cycle is consistent but machine angle is wrong, check converter mode, mechanical datum, pole mapping and alignment.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eTamagawa describes this redundant resolver for motor position and precision motion control with appropriate VRS conversion. Match the sensor build and converter mode in the actual drive. Tamagawa's redundancy feature does not substitute for machine safety-system validation. \u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/doublsyn\/\"\u003eDoublsyn design and application\u003c\/a\u003e · \u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/rd_converter\/vrdc\/\"\u003eTamagawa VRS conversion\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eCapture the original physical orientation and the machine's approved commutation\/angle reference before disturbing the sensor. Establish the relationship between the motor electrical cycle and the resolver's 4X output using the OEM procedure. Revalidate the converter configuration, direction and full system behavior. Any offset or commissioning data belong to the installed converter\/drive setup. Use the original motor's verified settings when restoration is approved. \u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/doublsyn\/\"\u003eTamagawa multiple-angle specification\u003c\/a\u003e · \u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/rd_converter\/vrdc\/\"\u003eConverter mode and setup\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/doublsyn\/\"\u003eTamagawa Doublsyn TSY7020 \/ TSY7030 product data\u003c\/a\u003e. Dimensions, excitation, transformation ratio and model comparison.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.tamagawa-seiki.com\/assets\/img\/downloads\/pdf\/resolver-synchro\/Doublsyn.pdf\"\u003eTamagawa Doublsyn and VRDC technical brochure (PDF)\u003c\/a\u003e. Manufacturer design and conversion reference.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/rd_converter\/vrdc\/\"\u003eTamagawa AUA6800 VRDC\u003c\/a\u003e. Converter modes, evaluation equipment and separate IC pin data.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.tamagawa-seiki.com\/products\/resolver-synchro\/singlsyn\/tsy1010\/\"\u003eTamagawa Singlsyn TSY1010\u003c\/a\u003e. Separate family and 4X comparison.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading (Est. 2003]","offers":[{"title":"Default Title","offer_id":51118266286245,"sku":"TYU2","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/TamagawaDoublsynTSY70204XResolver-TechnicalGuideServiceVisitforInstallation_Repair_Alignment.jpg?v=1794121632","url":"https:\/\/www.sparefaber.com\/products\/tamagawa-doublsyn-tsy7020","provider":"SpareFaber","version":"1.0","type":"link"}