{"product_id":"tamagawa-ts5669n220","title":"Tamagawa TS5669N220 TBLi-II SmartAbs Multiturn Encoder | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for TS5669N220 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"Tamagawa TS5669N220 TBLi-II SmartAbs Multiturn Encoder technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eWe check serial position, backup status and the in-motor loom, then assess the encoder fit and retained reference before replacement. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eThe Mitchell index documents the exact device and TI-5659 connection. Confirm the supported TI-5000JX profile and adapter with Mitchell before connecting. An approved SmartAbs receiver can compare within-turn count, turn count and serial response. Verify TI-3000JX support for the exact motor independently.\u003c\/p\u003e\n\u003ch2\u003eTamagawa TS5669N220 TBLi-II SmartAbs Multiturn Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003eTS5669N220\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTS5669N220\u003c\/th\u003e\n\u003ctd\u003eBuilt-in SmartAbs 35 motor feedback assembly, Ø35 mm class. Compare the exact seating and mounting dimensions in the catalogue.\u003c\/td\u003e\n\u003ctd\u003e17-bit single-turn and 16-bit multiturn. Mitchell lists TI-5659 for the TBLi-II 9-pin AMP application.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTS5667N120\u003c\/th\u003e\n\u003ctd\u003eRelated built-in model in Tamagawa's selection table.\u003c\/td\u003e\n\u003ctd\u003eCheck the exact catalogue entry, geometry and electrical assembly before sourcing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eTamagawa Europe lists this exact model. Confirm current orderability or any successor with Tamagawa for the specific motor build.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for TS5669N220\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for TS5669N220\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAbsolute data\u003c\/th\u003e\n\u003ctd\u003e17-bit position per revolution and 16-bit turn data, binary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial channel\u003c\/th\u003e\n\u003ctd\u003e2.5 Mbit\/s bidirectional NRZ with request\/response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating supply\u003c\/th\u003e\n\u003ctd\u003eNominal 5 V DC. Confirm the exact tolerance for the fitted revision because the catalogue specification and lead table show different tolerance wording.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNormal operating current\u003c\/th\u003e\n\u003ctd\u003e110 mA typical in the Tamagawa specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpeed and temperature\u003c\/th\u003e\n\u003ctd\u003e6,000 min⁻¹ max mechanically, −10 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation\u003c\/th\u003e\n\u003ctd\u003eBuilt-in open construction. Multiturn data backup uses the specified external battery.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/www.tjsolution.com\/TAMAGAWA\/1228n51.pdf\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThis SmartAbs build mounts inside a motor. Check Tamagawa’s drawing for the motor shaft, locating features and fastening geometry before choosing an assembly. The 35 mm class helps identify the package. Confirm the exact rotor engagement and stator location against the motor service drawing. During isolated work, look for debris, rubbing and a pinched lead.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe receiver requests position and other values over the bidirectional serial pair. The encoder replies with absolute position and turn data. The battery maintains turn information during power loss. Verify the exact drive protocol as well as its serial physical layer and battery circuit.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eThe Tamagawa catalogue gives the encoder lead functions below. Use the original connection figure for data polarity. Use the motor or Mitchell cable sheet for the numbered AMP cavities and the correct connector view.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"TS5669N220 catalogue lead groups\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eTS5669N220 catalogue lead groups\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eLead marking\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRed \/ black\u003c\/th\u003e\n\u003ctd\u003eMain 5 V supply \/ return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrown \/ brown-black\u003c\/th\u003e\n\u003ctd\u003eBackup battery supply \/ return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBlue \/ blue-black\u003c\/th\u003e\n\u003ctd\u003eSerial data pair, polarity per catalogue drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eInspect labels and verify continuity with the installed lead disconnected from both ends. Confirm how the OEM separates the supply and battery before connecting.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eMitchell lists TI-5659 for TBLi-II TS5669N220 with a 9-pin AMP connection. Its TS5669 family index also lists other plugs. Verify the exact OEM motor, cable part number and mating plug before choosing the adapter. The Tamagawa lead-wire colours apply to the catalogue assembly.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower present, no response\u003c\/th\u003e\n\u003ctd\u003eConfirm the receiver supports the exact protocol and serial data-pair wiring. Check supply at the encoder under the approved test load.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWithin-turn position works, turn count lost after shutdown\u003c\/th\u003e\n\u003ctd\u003eInspect the external battery circuit and record any backup alarms. Follow the OEM's restore and reference procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSerial dropouts change with motor vibration\u003c\/th\u003e\n\u003ctd\u003eInspect the AMP connector, retention, contact contamination and lead routing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition shift after mechanical work\u003c\/th\u003e\n\u003ctd\u003eCheck centring, retention and application-specific drive reference before writing any stored values.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eTamagawa lists TS5669N220 for built-in motor feedback. Mitchell names this exact encoder with the TBLi-II fixture. The complete fitted OEM motor code remains to be documented.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eRecord the as-found mounting and motor-specific drive parameters. Preserve valid position and battery-backed turn data according to the OEM procedure. Use the motor's documented commutation and reference steps after fitting. Confirm both within-turn position and retained turns before returning the machine to service.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.tjsolution.com\/TAMAGAWA\/1228n51.pdf\"\u003eMain technical PDF\u003c\/a\u003e. Tamagawa catalogue T12-1228N51, pages 45–46, manufacturer-authored copy. See the exact SmartAbs 35 motor mounting and lead table.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/tamagawa.eu\/products\/rotary-encoders\/absolute-encoder-multi-turn\/\"\u003eManufacturer reference\u003c\/a\u003e. Match the exact order code or the identified motor option.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.mitchell-electronics.com\/wp-content\/uploads\/2021\/07\/Test_Cable_Index_by_Mfr_Support.pdf\"\u003eMitchell manufacturer cable index\u003c\/a\u003e. Tamagawa TI-5659 application and 9-pin AMP description.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51124701397157,"sku":"TCG122","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/tamagawa-ts5669n220-service-guide.jpg?v=1794210232","url":"https:\/\/www.sparefaber.com\/products\/tamagawa-ts5669n220","provider":"SpareFaber","version":"1.0","type":"link"}