{"product_id":"te-2-1393047-5-v23401-s1001-b101-resolver","title":"TE Connectivity V23401-S1001-B101 2-1393047-5 Size-15 Hollow-Shaft Resolver | Technical Guide | Service Visit for Installation, Repair, Alignment","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003eSpareFaber offers UAE site visits for V23401-S1001-B101 installation, feedback diagnosis and alignment, and send-in evaluation for repair. We check the device, its mounting and the signal path to the controller so you can decide where to work next. Start with the exact code on the device label.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"TE Connectivity V23401-S1001-B101 2-1393047-5 Size-15 Hollow-Shaft Resolver technical guide\"\u003e\n\u003ch2 id=\"service\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eFeedback diagnosis, Installation, Alignment. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. \u003ca href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA resolver fixture can check winding integrity, transformation ratio, symmetry, phase and repeatability with approved excitation and load. Determine whether the exact resolver, wiring and excitation fit the chosen tester before assigning a Mitchell lead or run procedure.\u003c\/p\u003e\n\u003ch2\u003eTE Connectivity V23401-S1001-B101 2-1393047-5 Size-15 Hollow-Shaft Resolver technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e · \u003ca href=\"#mitchell-tests\"\u003eSpecialist testing\u003c\/a\u003e · \u003ca href=\"#encoder-enquiry\"\u003eEnquiry\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eUse the full label and suffix. The main reference is \u003cstrong\u003e2-1393047-5\u003c\/strong\u003e. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.\u003c\/p\u003e\n\u003cp\u003eManufacturer device order code\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Manufacturer part numbers\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eManufacturer part numbers\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eExact ID or order code\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical configuration\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eElectrical or service distinction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2-1393047-5 · V23401-S1001-B101\u003c\/th\u003e\n\u003ctd\u003eSize-15 hollow-shaft resolver. Match the dimensioned rotor, stator and lead exit.\u003c\/td\u003e\n\u003ctd\u003eOne pole pair, passive excitation and two secondary windings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2367254-1 · V23401-T2715-B101\u003c\/th\u003e\n\u003ctd\u003eDifferent size-21 resolver assembly.\u003c\/td\u003e\n\u003ctd\u003eSeparate two-pole-pair guide. Match mechanical and electrical requirements individually.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"production-status\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eThe listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Reference specifications for 2-1393047-5\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReference specifications for 2-1393047-5\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResolver type\u003c\/th\u003e\n\u003ctd\u003eSize 15, one pole pair, TE item 2-1393047-5.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReference test\u003c\/th\u003e\n\u003ctd\u003eTE sheet specifies 7.0 V RMS input, 10 kHz typical. Use the approved receiver and specified test conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTransformation ratio\u003c\/th\u003e\n\u003ctd\u003eNominal 0.50 in the exact data sheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003eTwo AC secondary voltages whose amplitudes depend on rotor angle.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMechanical fit\u003c\/th\u003e\n\u003ctd\u003eSee the exact revision D2 customer drawing for bore, stator pilot and mounting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe table identifies the assembly each value applies to. \u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocFormat=pdf\u0026amp;DocLang=English\u0026amp;PartCntxt=2-1393047-5\u0026amp;DocNm=2-1393047-5_DATA_SHEET\u0026amp;DocType=Data+Sheet\"\u003eMain technical PDF\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eMeasure the motor shaft and resolver seating features from the exact D2 drawing. Protect the windings and keep the rotor and stator from touching. Compare cable exit, axial position and original witness marks before making adjustments.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe drive supplies an AC excitation to the primary. The two secondaries return carrier signals scaled by rotor angle. A resolver-to-digital converter uses their ratio and phase to calculate position. One pole pair gives one electrical cycle per mechanical revolution.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eThe following winding names are from the TE data sheet for V23401-S1001-B101. Use the customer drawing and equipment wiring for lead identification.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Verified contact map\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eVerified contact map\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eContact or group\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eR1–R2\u003c\/th\u003e\n\u003ctd\u003eExcitation winding.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eS1–S3\u003c\/th\u003e\n\u003ctd\u003eCosine secondary under TE’s stated viewing and polarity convention.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eS2–S4\u003c\/th\u003e\n\u003ctd\u003eSine secondary under the same convention.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eUse the fitted equipment drawing to identify winding pairs, polarity, shield and any machine connector. The TE drawing covers the resolver assembly. It does not establish a specific motor loom or tester cable.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal checks.\u003c\/strong\u003e Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation before internal work.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHarness continuity.\u003c\/strong\u003e Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"Use the symptom to choose the next check\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eUse the symptom to choose the next check\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eObservation\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNo usable output from either secondary\u003c\/th\u003e\n\u003ctd\u003eCheck whether the approved receiver is supplying excitation. Inspect the disconnected harness and compare primary and secondary winding resistance with a known reference for this exact part.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOnly one track is low or distorted\u003c\/th\u003e\n\u003ctd\u003eCheck the corresponding winding, pair wiring, load and rotor\/stator seating. Compare both tracks with controlled rotation on a suitable fixture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAngle reads but commutation is wrong\u003c\/th\u003e\n\u003ctd\u003eVerify phase convention, polarity and rotor-to-motor alignment against the OEM procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePowered checks.\u003c\/strong\u003e A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse the exact TE item for assemblies whose drawing specifies this rotor and stator. The public data sheet does not identify a universal motor or drive. Record the machine, motor and resolver receiver model for service.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eTE defines an electrical zero by the S2–S4 null and S1–S3 phase relationship in the exact sheet. The installed motor commutation offset still comes from the motor builder’s procedure. Record the original reference before removing the resolver.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocFormat=pdf\u0026amp;DocLang=English\u0026amp;PartCntxt=2-1393047-5\u0026amp;DocNm=2-1393047-5_DATA_SHEET\u0026amp;DocType=Data+Sheet\"\u003eMain technical PDF\u003c\/a\u003e. Exact TE electrical data sheet with winding functions, test conditions and reference convention. Use the separate drawing for fit.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.te.com\/en\/product-2-1393047-5.html\"\u003eManufacturer reference\u003c\/a\u003e. Match the exact order code or the identified motor option.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.te.com\/commerce\/DocumentDelivery\/DDEController?Action=srchrtrv\u0026amp;DocFormat=pdf\u0026amp;DocLang=English\u0026amp;PartCntxt=2-1393047-5\u0026amp;DocNm=2-1393047-5\u0026amp;DocType=Customer+Drawing\"\u003eTE dimensioned customer drawing D2\u003c\/a\u003e. Check rotor, stator, mounting and lead details for item 2-1393047-5.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.te.com\/en\/product-2367254-1.html\"\u003eTE size-21 comparison\u003c\/a\u003e. Related technology with different size and pole count.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e\n","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51126568550565,"sku":"TCG155","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/te-2-1393047-5-v23401-s1001-b101-resolver-service-guide.jpg?v=1794221192","url":"https:\/\/www.sparefaber.com\/products\/te-2-1393047-5-v23401-s1001-b101-resolver","provider":"SpareFaber","version":"1.0","type":"link"}