{"product_id":"tr-electronic-cev582m-10539","title":"TR-Electronic CEV582M-10539 PROFIBUS DP Encoder | Technical Guide \u0026 Service","description":"\u003cdiv class=\"sf-feedback-intro\"\u003e\n\u003cp\u003e\u003cstrong\u003ePROFIBUS node failing after an encoder swap?\u003c\/strong\u003e SpareFaber can check the CEV582M-10539 power, bus wiring, GSD, address, mounting and preset at your UAE site. A bench check can separate encoder faults from a segment or PLC configuration problem.\u003c\/p\u003e\n\u003cp class=\"sf-feedback-intro__actions\"\u003e\u003ca class=\"sf-feedback-intro__primary\" href=\"#encoder-enquiry\"\u003eRequest a UAE site visit or bench evaluation\u003c\/a\u003e \u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e \u003ca href=\"#diagnose\"\u003eTrace a fault\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003carticle class=\"feedback-guide\" aria-label=\"TR-Electronic CEV582M-10539 PROFIBUS DP Encoder technical guide\"\u003e\n\u003ch2 id=\"service\" style=\"scroll-margin-top: 6rem;\"\u003eSite visit or send-in evaluation\u003c\/h2\u003e\n\u003cp\u003eSend the full TR order number, old encoder plate, PLC\/master, station address and bus LED pattern. Include the drawing or photo of the connection cap, the old GSD and the configured scale. Use the \u003ca href=\"#encoder-enquiry\"\u003eenquiry form\u003c\/a\u003e to share the details.\u003c\/p\u003e\n\u003ch2 id=\"mitchell-tests\" style=\"scroll-margin-top: 6rem;\"\u003eWhat specialist testing can show\u003c\/h2\u003e\n\u003cp\u003eA compatible PROFIBUS DP master and bus analyzer can verify node entry into data exchange, parameterization, status and position. Compare the response on an isolated service segment with a properly terminated setup. Verify mechanical rotation and preset independently. Exact Mitchell TI-5000JX and TI-3000JX support for this fieldbus model was not verified. \u003ca href=\"https:\/\/www.trelectronic.com\/file\/31428\/download?token=RrBrMMk3\"\u003eTR exact pin and termination sheet (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.tr-electronic.com\/service\/downloads\/operating-manuals\/encoder-and-linear-transducer\"\u003eTR PROFIBUS interface manuals\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eTR-Electronic CEV582M-10539 PROFIBUS DP Encoder technical reference\u003c\/h2\u003e\n\u003cnav aria-label=\"On this page\"\u003e\u003ca href=\"#identify\"\u003eFind my part number\u003c\/a\u003e · \u003ca href=\"#production-status\"\u003eProduction status\u003c\/a\u003e · \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#mounting\"\u003eMounting\u003c\/a\u003e · \u003ca href=\"#interface\"\u003eInterface\u003c\/a\u003e · \u003ca href=\"#wiring\"\u003eWiring\u003c\/a\u003e · \u003ca href=\"#motor-cables\"\u003eCables\u003c\/a\u003e · \u003ca href=\"#diagnose\"\u003eFault checks\u003c\/a\u003e · \u003ca href=\"#applications\"\u003eApplications\u003c\/a\u003e · \u003ca href=\"#alignment\"\u003eAlignment\u003c\/a\u003e · \u003ca href=\"#documents\"\u003eManuals\u003c\/a\u003e · \u003ca href=\"#service\"\u003eService\u003c\/a\u003e\u003c\/nav\u003e\n\u003csection id=\"identify\"\u003e\n\u003ch2\u003eFind your part number\u003c\/h2\u003e\n\u003cp\u003eRead \u003cstrong\u003eCEV582M-10539\u003c\/strong\u003e from the order field. The reference data sheet also names \u003cstrong\u003eCEV58M-00539\u003c\/strong\u003e. Match the complete suffix, shaft D-cut, flange and terminal configuration. Save the bus settings and preset before disconnecting.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"TR order numbers and replacement scope\" tabindex=\"0\"\u003e\n\u003ctable id=\"id-table\"\u003e\n\u003ccaption\u003eTR order numbers and replacement scope\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eOrder number\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePosition and interface\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMechanical \/ application note\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCEV582M-10539\u003c\/th\u003e\n\u003ctd\u003e4096 steps × 4096 revolutions, PROFIBUS DP, binary\u003c\/td\u003e\n\u003ctd\u003eZB85 flange, Ø10 mm D-cut solid shaft. Main terminal map below.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCEV58M-00539\u003c\/th\u003e\n\u003ctd\u003eEarlier unit named in the TR alternative field\u003c\/td\u003e\n\u003ctd\u003eUse its own nameplate and legacy hardware record for exact configuration. Confirm migration in the controller.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCEV582M-00067\u003c\/th\u003e\n\u003ctd\u003e8192 steps × 4096 revolutions, separate PROFIBUS build\u003c\/td\u003e\n\u003ctd\u003eOther order code with its own drawing and connection details.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.trelectronic.com\/file\/31428\/download?token=RrBrMMk3\"\u003eTR CEV582M-10539 exact data (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.tr-electronic.de\/produktselektor?cHash=b54baaa2aea7547f0c01635972133063\u0026amp;tx_mtmtrproductselector_productselector%5Baction%5D=getAggregateManualPdf\u0026amp;tx_mtmtrproductselector_productselector%5Bcontroller%5D=Selektor\u0026amp;tx_mtmtrproductselector_productselector%5Bid%5D=CEV582M-00067\u0026amp;type=41459404\"\u003eTR 00067 comparison record (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3 id=\"production-status\" style=\"scroll-margin-top: 6rem;\"\u003eProduction and end-of-life status\u003c\/h3\u003e\n\u003cp\u003eTR's exact sheet marks CEV582M-10539 as the alternative for \u003cstrong\u003eCEV58M-00539\u003c\/strong\u003e. It establishes an OEM-documented replacement pair. Confirm current orderability, revision and legacy support directly with TR. \u003ca href=\"https:\/\/www.trelectronic.com\/file\/31428\/download?token=RrBrMMk3\"\u003eTR exact alternative and drawing (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"CEV582M-10539 exact data\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCEV582M-10539 exact data\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue and source scope\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePosition\u003c\/th\u003e\n\u003ctd\u003e4096 steps\/rev × 4096 revolutions, binary and parameterizable via the interface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNetwork\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS DP. TR-ECE-TI-GB-0065 terminal sheet for the documented cap.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003eOverview lists 10–30 V DC. The attached X1\/X2 wiring sheet labels US 11–27 V DC. Confirm requirements for the actual cap and unit with TR before applying power.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFit\u003c\/th\u003e\n\u003ctd\u003eZB85 locating geometry, Ø10 × 19.5 mm nominal D-cut solid shaft. Use drawing 04-CEV582M-M0236.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnvironment and entry\u003c\/th\u003e\n\u003ctd\u003eIP65, −20 to +75 °C. One M12 and two M16 cable glands, radial.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.trelectronic.com\/file\/31428\/download?token=RrBrMMk3\"\u003eTR exact data, drawing and terminal notes (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"mounting\"\u003e\n\u003ch2\u003eMounting and fit\u003c\/h2\u003e\n\u003cp\u003eThe solid shaft is driven through a suitable separate coupling and the housing mounts to the machine. Compare the D-flat and centering features with drawing 04-CEV582M-M0236. Check for shaft preload, a missing restraint or a slipped coupling under isolation. Use the machine and coupling manufacturer's instructions for fasteners. Route cables within the illustrated bend limits so the glands are secure and the cap seals correctly. \u003ca href=\"https:\/\/www.trelectronic.com\/file\/31428\/download?token=RrBrMMk3\"\u003eTR exact mechanical drawing (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"interface\"\u003e\n\u003ch2\u003eInterface and measuring method\u003c\/h2\u003e\n\u003cp\u003eThe encoder is an absolute multiturn slave. The PROFIBUS DP master uses the correct GSD and encoder module to configure it and read position cyclically. The physical turn count and the configured measuring units are separate. A node can exchange data while the PLC has the wrong scaling, direction or preset. Compare the raw value over a known rotation to the PLC display.\u003c\/p\u003e\n\u003cp\u003eBefore replacing the 00539, record the current address, master project, configured module, scaling and preset. Match the replacement's GSD and behavior to the PLC project before releasing the machine. \u003ca href=\"https:\/\/www.trelectronic.com\/file\/31428\/download?token=RrBrMMk3\"\u003eTR device-specific notes (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.tr-electronic.com\/service\/downloads\"\u003eTR GSD and device documentation downloads\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"wiring\"\u003e\n\u003ch2\u003eVerified wiring\u003c\/h2\u003e\n\u003cp\u003eUse the following only for the \u003cstrong\u003eX1\/X2 four-position screw clamps\u003c\/strong\u003e shown in the manufacturer sheet included for 10539. Confirm terminal markings at the cap and preserve the IN\/OUT arrangement.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; contain: inline-size;\" role=\"region\" aria-label=\"TR-ECE-TI-GB-0065 terminals\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eTR-ECE-TI-GB-0065 terminals\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePosition\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eX1 bus in\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eX2 bus out\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e1\u003c\/th\u003e\n\u003ctd\u003eData A IN\u003c\/td\u003e\n\u003ctd\u003eData A OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e2\u003c\/th\u003e\n\u003ctd\u003eData B IN\u003c\/td\u003e\n\u003ctd\u003eData B OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e3\u003c\/th\u003e\n\u003ctd\u003eUS supply, terminal sheet 11–27 V DC\u003c\/td\u003e\n\u003ctd\u003eUS supply, terminal sheet 11–27 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e4\u003c\/th\u003e\n\u003ctd\u003eGND \/ 0 V\u003c\/td\u003e\n\u003ctd\u003eGND \/ 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe termination switch S3 is ON at the end of the segment for the documented arrangement. It disconnects the downstream A\/B paths when switched on. Follow TR's reference-potential and power-feed notes for the last station. Set the station number on S1\/S2 only as the approved bus plan specifies. \u003ca href=\"https:\/\/www.trelectronic.com\/file\/31428\/download?token=RrBrMMk3\"\u003eTR terminal assignment, switches and grounding (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"motor-cables\"\u003e\n\u003ch2\u003eCables inside the motor and at the machine\u003c\/h2\u003e\n\u003cp\u003eThis model has glands and screw clamps at the machine. It has no in-motor PCB-to-M23 loom. Use the approved PROFIBUS cable and shield termination, match the gland clamping range and keep the documented bend radius. The exact sheet shows cable entry sizes and X1\/X2 functions. Use the PLC\/vendor documentation for the far-end connector and address any separately powered segment ends. \u003ca href=\"https:\/\/www.trelectronic.com\/file\/31428\/download?token=RrBrMMk3\"\u003eCable gland and terminal drawing (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"diagnose\"\u003e\n\u003ch2\u003eFault checks\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCoordinate a controlled stop before opening the cap.\u003c\/strong\u003e Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized. Disconnecting an intermediate node can interrupt other stations.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead the master first.\u003c\/strong\u003e Record the failed station, LED pattern, address and whether all downstream nodes are affected. Check status against the exact LED legend.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect and check the detached branch.\u003c\/strong\u003e With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Check A\/B order, shield continuity, clamp seating, contamination and terminating components. Take into account any intentional termination when testing a cable with connectors attached.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck power and configuration.\u003c\/strong\u003e With an approved breakout and controlled energized procedure, measure US to GND under load, using the confirmed supply limits. Verify S3, station address, GSD and PLC module parameters. A multimeter can check supply and wiring but a bus analyzer is needed for data faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterpret.\u003c\/strong\u003e If stations beyond this cap drop out after a swap, check S3 and pass-through. If the device is in data exchange but the reading is wrong, compare raw position, scaling and preset and check coupling. Persistent device memory or position errors on a verified service segment warrant specialist testing.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/section\u003e\n\u003csection id=\"applications\"\u003e\n\u003ch2\u003eMotor and drive applications\u003c\/h2\u003e\n\u003cp\u003eUse this unit on a compatible PROFIBUS DP segment for absolute shaft or machine-axis position. It is not an SSI or PROFINET substitution. Verify the network class, firmware and machine scaling in the engineering project. \u003ca href=\"https:\/\/www.trelectronic.com\/file\/31428\/download?token=RrBrMMk3\"\u003eTR exact fieldbus identification (PDF)\u003c\/a\u003e · \u003ca href=\"https:\/\/www.tr-electronic.com\/service\/downloads\/operating-manuals\/encoder-and-linear-transducer\"\u003eTR PROFIBUS reference manual list\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"alignment\"\u003e\n\u003ch2\u003eAngle of alignment and commissioning\u003c\/h2\u003e\n\u003cp\u003eCommission mechanical coupling, count direction, station number and machine datum. Back up the original PLC and encoder configuration. Apply an approved preset at a known standstill position and confirm actual movement and wrap after replacement. Any separate motor commutation procedure belongs to the servo's motor feedback. \u003ca href=\"https:\/\/www.tr-electronic.com\/service\/downloads\/operating-manuals\/encoder-and-linear-transducer\"\u003eTR PROFIBUS commissioning and preset resources\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\"\u003e\n\u003ch2\u003eDrawings, pin maps and manuals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.trelectronic.com\/file\/31428\/download?token=RrBrMMk3\"\u003eTR CEV582M-10539 exact package (PDF)\u003c\/a\u003e. Order number, OEM alternative, mounting drawing, connector sheet and S1\/S2\/S3 details.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.tr-electronic.de\/produktselektor?cHash=b54baaa2aea7547f0c01635972133063\u0026amp;tx_mtmtrproductselector_productselector%5Baction%5D=getAggregateManualPdf\u0026amp;tx_mtmtrproductselector_productselector%5Bcontroller%5D=Selektor\u0026amp;tx_mtmtrproductselector_productselector%5Bid%5D=CEV582M-00067\u0026amp;type=41459404\"\u003eTR CEV582M-00067 aggregate documentation (PDF)\u003c\/a\u003e. Different resolution build. Use the exact 10539 wiring sheet for the main unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.tr-electronic.com\/service\/downloads\"\u003eTR downloads\u003c\/a\u003e. GSD, product information and documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.tr-electronic.com\/service\/downloads\/operating-manuals\/encoder-and-linear-transducer\"\u003eTR encoder and linear-transducer interface manuals\u003c\/a\u003e. Select the applicable PROFIBUS profile and revision.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e","brand":"Ajman Factories Equipment Trading","offers":[{"title":"Default Title","offer_id":51118245544101,"sku":"TXG01","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/TR-ElectronicCEV582M-10539PROFIBUSDPEncoder.jpg?v=1794143215","url":"https:\/\/www.sparefaber.com\/products\/tr-electronic-cev582m-10539","provider":"SpareFaber","version":"1.0","type":"link"}