{"product_id":"ul24i16o_input-output-wiring-module-pp72-48-sinumerik-802","title":"UL24I16O Input Output Wiring module-PP72\/48 Sinumerik 802 | Relay Module UL 24 Input 16 Ouptut","description":"\u003cdiv class=\"svelte-1mls9rg\"\u003e\n\u003cdiv class=\"product-main__media-gallery product-main__media-gallery--sticky-to-top svelte-1mls9rg\"\u003e\n\u003cdiv class=\"host media-gallery svelte-1s8x2ra\"\u003e\n\u003cdiv class=\"desktop-media svelte-1s8x2ra\"\u003e\n\u003cdiv class=\"thumbnails__wrapper svelte-1s8x2ra\"\u003e\n\u003ch1 class=\"thumbnails__item svelte-1qngyo3\"\u003e\u003cbr\u003e\u003c\/h1\u003e\n\u003ch1 class=\"thumbnails__item svelte-1qngyo3\"\u003eUL24I16O Modular Wiring Solutions | CNC Interface Modules Relay Module - \u003c\/h1\u003e\n\u003ch1 class=\"thumbnails__item svelte-1qngyo3\"\u003e50 PIn FRC Connector to 24 Digital Inputs\/ 16 Digital Outputs Field wiring module\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"thumbnails__item svelte-1qngyo3\"\u003eInput Output Wiring module | UL24116O Panel-Machine- PP72\/48 Sinumerik 802\u003c\/h2\u003e\n\u003cp\u003eTerminals for 24 Inputs and 15 Relays available as Output for use via terminals for wiring along with LED indication.\u003c\/p\u003e\n\u003cp\u003eSystem Input Data\u003cbr\u003eNumber of Inputs \u0026amp; Outputs 24 Digital Inputs \u0026amp; 16 Digital Outputs\u003cbr\u003eInput Signal Voltage 24VDC\u003cbr\u003eSignal Mode Non-Redundant\u003cbr\u003eInput Status LED\/Channel Green LED\u003cbr\u003eProtection Back emf\u003cbr\u003eSignal Configuration Source\u003cbr\u003eTermination 50 Pin FRC Connector\u003cbr\u003eField Output Data\u003cbr\u003eOutput Signal Voltage 24VDC\u003cbr\u003eSignal Configuration Pot-free\u003cbr\u003eContact Configuration DPDT, 2 Change Over\u003cbr\u003eContact current rating 5Am @ 230VAC \/ 24VDC\u003cbr\u003eProtection Short Circuit (refer selection matrix)\u003cbr\u003eFuse Type Glass Fuse\u003cbr\u003eField Side Termination\u003cbr\u003eTerminal Type Screw Terminal\u003cbr\u003eNominal Current \/Sq.mm 24A\/ 2.5mm²\u003cbr\u003eRated Voltage 250V\u003cbr\u003eRated surge Voltage 4KV\u003cbr\u003eSolid\/ Stranded 0.2-4\/ 0.2-2.5\/ 24-12\u003cbr\u003e[mm²\/ mm²] AWG\u003cbr\u003eInsulation material PA\/I\u003cbr\u003eTightening torque 0.6 Nm Max.\u003cbr\u003eField Side Power Supply\u003cbr\u003eAux Voltage 24VDC\/110VAC\/230VAC\u003cbr\u003ePower ON Status Green LED\u003c\/p\u003e\n\u003cp\u003e-------------\u003c\/p\u003e\n\u003cp\u003eSystem Side Termination\u003cbr\u003eTerminal Type 50 Pin FRC Connector\u003cbr\u003eContact Material Copper Alloy\u003cbr\u003e0 Operating Current 1.5A per contact @ 20C\u003cbr\u003eContact Resistance ≤20m\u003cbr\u003eInsulation Resistance ≥5000MΩ @ 100V\u003cbr\u003e@ 500Vdc\u003cbr\u003eDielectric Withstanding 1000 Vrms\u003cbr\u003eVoltage\u003cbr\u003eRelay Data\u003cbr\u003eRelay Make Omron, G2RL Series or Equivalent\u003cbr\u003eContact Type DPDT, 2 Change Over\u003cbr\u003eApprovals\u003cbr\u003eRelay Socket\u003cbr\u003eRated values 5A AC\/ DC, 250V rms\u003cbr\u003eDielectric strength 2000V AC rms for 1 min.\u003cbr\u003eInsulation resistance 1000MΩ at 500V DC\u003cbr\u003eAmbient temperature -45 to +120˚C\u003cbr\u003eGeneral Data\u003cbr\u003eAmbient temperature 0°C to +60°C\u003cbr\u003eRelative humidity Max. 90% (Non-condensing)\u003cbr\u003ePCB design UL standard ANSI IPC 2221,2222 \u0026amp;\u003cbr\u003eMIL 275B\u003cbr\u003eScrew- Terminals UL, CSA Standard \u0026amp; CE standard\u003cbr\u003eMounting Universal Rail Mounting\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/Sinumerik_802_PP7248_Wiring_modules_-_MCP_to_PP7248_Machine_to_INput_output_module_1.png?v=1790410454\" alt=\"Connection diagram of Sinumerik 802 PP 72\/48 and MCP field wiring\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/Sinumerik_802_PP7248_Wiring_modules_-_MCP_to_PP7248_Machine_to_INput_output_module_3.png?v=1790410454\" alt=\"MCP does not use all Inputs and outputs many iO gets released if you use a Special wiring module Connection diagram of Sinumerik 802 PP 72\/48 and MCP field wiring\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/Sinumerik_802_PP7248_Wiring_modules_-_MCP_to_PP7248_Machine_to_INput_output_module_2.png?v=1790410454\" alt=\"PP7248 and its wiring for Sinumerik 802\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"UL Automation | Sinumerik","offers":[{"title":"Default Title","offer_id":50535083737253,"sku":"SVN8","price":496.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0775\/3557\/6229\/files\/UL24I16O_RelayModule_3.jpg?v=1790412179","url":"https:\/\/www.sparefaber.com\/products\/ul24i16o_input-output-wiring-module-pp72-48-sinumerik-802","provider":"SpareFaber","version":"1.0","type":"link"}