Site visit or send-in evaluation
Draw-wire diagnosis, Installation, Travel verification. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A fixture can compare position against known travel and evaluate SSI response with the specified receiver. Inspect cable travel and return independently. Exact Mitchell fixture support remains open.
ASM POSIWIRE WS12 WS12-3000-50-MSSI-L10-M4-M12A8 SSI Draw-Wire Position Sensor technical reference
Find your part number
Use the full label and suffix. The main reference is WS12-3000-50-MSSI-L10-M4-M12A8. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
ASM documents this as a standard ordering example. Match the complete fitted nameplate and drawing before using its specifications.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| WS12-3000-50-MSSI-L10-M4-M12A8 | 3,000 mm draw-wire range, M4 cable fixing and 8-pin M12 electrical connection. | 50 µm resolution, MSSI output, L10 linearity option. |
| WS12 with another output suffix | The cable stroke and attachment may differ. | Match SSI versus analogue, incremental or fieldbus variant from the actual code. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Measuring range | 3,000 mm in the ordering example. |
| Resolution and linearity | 50 µm resolution. L10 denotes ±0.10% of full scale in the ASM order key. |
| Mechanical attachment | M4 draw-wire fixing. Check the intended travel path, retraction limits and housing drawing. |
| Electrical connection | M12A8, 8-pin M12 for this ordering example. |
| Interface | MSSI synchronous serial output. Match data length, encoding and receiver settings from the MSSI section. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Align the cable outlet with the full travel and use the specified attachment. Avoid side pull, abrasion and overtravel. Route the moving cable so it cannot catch on a guard, sheave or cable chain.
Interface and measuring method
The draw-wire mechanism converts travel into rotation inside the housing. A magnetic absolute encoder reports position via synchronous serial clock and data. A mechanically stuck or slipping cable can return a stable digital value that disagrees with actual travel.
Verified wiring
Use the MSSI connection table for the actual M12A8 configuration, paying attention to the mating-connector view. Verify supply/return, differential clock and data pairs, and shield. Use the table for the exact output because other WS12 variants share the housing.
Cables inside the motor and at the machine
The draw wire is the measuring element. The separate M12 cordset carries SSI and supply. Match ASM’s M12A8 accessory and the receiving hardware before ordering an extension.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Secure the moving load and keep clear of the spring-loaded draw wire. Do not release an extended cable or dismantle the spring housing as part of a basic check.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Value stops changing partway through travel | Check the physical attachment and line of pull, then compare actual displacement with the readout. |
| Wire retracts poorly or visibly frays | Secure the load and isolate the assembly. Inspect the route and attachment. Arrange replacement or specialist inspection for the spring-loaded mechanism. |
| Travel is smooth but reading has steps or dropouts | Check SSI timing, bit format, supply and isolated wiring. Compare several measured distances to the raw word. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use the ordered 3 m sensor on equipment with matching travel, fixing and SSI receiver. Record the cordset, receiver settings and original machine reference.
Angle of alignment and commissioning
Set travel and zero from the machine drawing and verify the usable movement remains within the rated range. Recheck scaling and direction after fitting. This is a linear reference procedure.
Drawings, pin maps and manuals
- Main technical PDF. WS12 drawings and connections. Use the magnetic SSI section for the exact documented MSSI ordering example.
- Manufacturer reference. Match the exact order code or the identified motor option.
- ASM POSIWIRE order catalogue. See the WS12 MSSI example and decoding of all six options.