Site visit or send-in evaluation
Feedback diagnosis, Installation, Alignment. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A suitable Start/Stop receiver or timing fixture can check pulse response and travel against a known magnet position. Validate cylinder fit, pressure sealing and travel separately on the installed equipment.
Balluff BTL02JK BTL5-P1-M0500-H-SA220-KA05 Start/Stop Linear Position Sensor technical reference
Find your part number
Use the full label and suffix. The main reference is BTL5-P1-M0500-H-SA220-KA05. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
Manufacturer device order code
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| BTL02JK · BTL5-P1-M0500-H-SA220-KA05 | 500 mm compact rod, M18 × 1.5 mounting thread, 5 m PUR cable. | Start/Stop and Start/Stop negative per exact Balluff product record. |
| BTL5-P1 H/W family | Different stroke, thread, cable or special option may be fitted. | Use the entire designation. Confirm any SA suffix with Balluff. |
Production and end-of-life status
Balluff lists this item in its Classic portfolio with extended availability and no new design-in. Check the exact SA220 order and availability with Balluff.
Specifications
| Parameter | Value and scope |
|---|---|
| Measuring range | 500 mm for BTL02JK. |
| Supply | 20–28 V DC on the exact Balluff product record. |
| Mount | Compact rod series, M18 × 1.5 threaded flange. Stainless steel housing listed. |
| Electrical | Fixed 5 m PUR cable. Start/Stop pulse interfaces. |
| Product status | Balluff Classic portfolio with extended availability and no new design-in, per item record. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Secure the cylinder and load. Verify the non-contact position magnet type, coaxial placement, rod clearance and mechanical travel against the cylinder drawing. Use the exact flange and seal arrangement before putting the assembly under pressure.
Interface and measuring method
The controller initiates or receives the timing sequence specified for its Start/Stop mode. The transit time associated with the magnet position is converted to travel. Verify the receiver’s timing mode and scaling, especially after an input module change.
Verified wiring
Use the exact BTL02JK datasheet and receiver diagram to identify supply, return, pulse signals, polarity and shield. The family guide shows several output arrangements. Confirm the special SA220 configuration before using a family colour table.
Cables inside the motor and at the machine
The factory sensor lead is a 5 m fixed PUR cable. Record the machine termination or junction and the controller input module. Identify any extension from the controller drawing and confirm the prescribed cable and shielding.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Before working on the cylinder, isolate hydraulic and stored pressure energy using the machine procedure and secure gravity-loaded motion. Electrical isolation alone does not make the cylinder safe.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Reading frozen at one value | Check actual travel and magnet attachment. Check the timing receiver and initiation/return path on a qualified setup. |
| Fault only near one travel end | Check magnet travel relative to the rated stroke and the controller’s valid window. |
| Reading jumps when the hydraulic valve operates | Inspect cable routing, screen bonds and receiver diagnostics. Compare with the actual movement and supply at the specified load. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use the BTL02JK exact order for a cylinder or linear assembly specifying the 500 mm rod, magnet and Start/Stop receiver. Capture the cylinder drawing and PLC or controller part number before a site visit.
Angle of alignment and commissioning
Set magnet geometry and travel limits from the cylinder and Balluff instructions. Reconfirm controller zero, direction and scaling against physical references. The device has no servo commutation angle.
Drawings, pin maps and manuals
- Main technical PDF. Balluff-authored P/I1 H/W family installation guide, public mirror. Verify the exact SA220 option on the Balluff item sheet.
- Manufacturer reference. Match the exact order code or the identified motor option.