Site visit or send-in evaluation
Provide the full Baumer code, PLC project version, device name, module/telegram, raw position and the LED pattern. Include the old and new labels, network topology and photos of the shaft restraint. Use the enquiry form to share the details.
What specialist testing can show
A compatible PROFINET engineering station can identify the encoder, check port and module status and compare raw cyclic position with known motion. Use an isolated service network for testing a spare. Preserve the running project before any naming, mapping or parameter changes. Exact Mitchell JX coverage for this network encoder was not verified. Baumer PROFINET commissioning and status (PDF)
Baumer EAM580-BAC.5YPT.14160.A PROFINET Encoder technical reference
Find your part number
Read EAM580-BAC.5YPT.14160.A all the way to the end. The catalogue identifies this code as magnetic multiturn PROFINET with a 12 mm blind hollow shaft. Similar three-connector housings can carry a different Ethernet protocol. Match the full type, mechanical restraint and controller profile.
| Order code | Interface and position | Fit / difference |
|---|---|---|
| EAM580-BAC.5YPT.14160.A | PROFINET IO, 14-bit singleturn and 16-bit multiturn | Ø12 mm blind hollow shaft, magnetic EAM580 |
| EAM580-BAC.5YEN.14160.A | EtherNet/IP, 14-bit singleturn and 16-bit multiturn | Similar EAM580 build. Different controller interface. |
| EAL580-TNC.5WPT.18130.A | PROFINET IO, 18-bit singleturn and 13-bit multiturn | Optical EAL580, separate mechanical drawing and data selection. |
EAM580 5YPT exact build · EAM580 5YEN comparison · EAL580 exact comparison
Production and end-of-life status
Baumer publishes the exact PROFINET build and describing files in its product catalogue. Confirm lifecycle and delivery for the full type or serial number with Baumer. Baumer exact product and downloads
Specifications
| Parameter | Value for the cited type |
|---|---|
| Position | Magnetic multiturn. 16,384 native steps per turn and 65,536 turns. A PLC may receive a scaled value. |
| Supply | 10–30 V DC, 90 mA typical at 24 V without load, initialization ≤10 s. |
| Interface | PROFINET IO, three M12 flange connectors. Two data ports and a separate power connection. |
| Fit | Ø58 mm flange, Ø12 mm blind hollow shaft. Catalogue operating speed ≤6000 rpm. |
| Environment | IP65 without shaft seal for this record. −40 to +85 °C per catalogue general information. |
Baumer exact technical and mechanical data · EAx580 PROFINET manual (PDF)
Mounting and fit
Check the blind bore depth and shaft end against the exact CAD drawing. Use the specified clamp and housing restraint to hold the encoder body with the permitted freedom of movement. A bottomed shaft, bent stator coupling or over-tightened restraint can make the measurement drift or damage bearings. Follow the exact dimension and fastener instructions for the type fitted. Keep the axial M12 cable exit clear. Baumer CAD and type-specific drawings · Baumer hollow-shaft assembly section (PDF)
Interface and measuring method
PROFINET exchanges position with the PLC using the selected device configuration and telegram. Match the GSDML, device name, hardware module and topology in the controller. A link LED only indicates a physical connection. Check that the PLC is exchanging data with the intended name and expected profile. Compare the raw position, preset, scaling and counting direction before changing the sensor. PROFINET name, module and operating modes (PDF) · Baumer EAx580 profile and GSDML note (PDF)
Verified wiring
The Baumer EAx PROFINET manual documents these numbered assignments for the separate A-coded power and D-coded bus connectors. Match the orientation and port identification on the fitted unit.
| Pin | A-coded power M12 | D-coded PROFINET M12 |
|---|---|---|
| 1 | UB, 10–30 V DC | TxD+ |
| 2 | Do not connect | RxD+ |
| 3 | GND | TxD− |
| 4 | Do not connect | RxD− |
Use P1/P2 as required by the planned topology. Preserve screen and port sealing. The EtherNet/IP alternative has separate documentation. Baumer connector assignment and LEDs (PDF)
Cables inside the motor and at the machine
This external encoder uses a separate power cord and shielded Ethernet leads. Baumer lists D-coded field connector Z 185.S01 (11174046) and D-coded 5 m shielded cordset Z 185.E05 (11034355) in the EAM580 PROFINET family. Verify the far-end connector, planned topology and cable motion rating. Use an A-coded mating power cord per the manual and preserve the separate cable routes. Baumer EAM580 PROFINET cable accessories · Baumer power and data cable requirements (PDF)
Fault checks
Coordinate an approved stop before disconnecting a port or touching the shaft. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
- Record. Save the station name, active device/module, fault and port LEDs. Compare the physical plate with the projected device.
- Inspect and isolate the harness. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Verify A-coded power versus D-coded data, secure connector coupling and shield. Use a suitable cable tester to check data-pair integrity.
- Check the supply and network. A qualified technician can install a documented power breakout under isolation and then measure pin 1 relative to 3 under load during the approved test. Check switch/PLC topology, device name and correct GSDML.
- Separate position errors. Correct raw data with wrong engineering units suggests PLC scaling or preset. Raw position drifting relative to the axis points toward the shaft clamp or mechanical reference. Failure to enter data exchange despite healthy links calls for configuration diagnosis before replacement.
Motor and drive applications
Use with a compatible PROFINET IO controller and matching project, e.g. the Siemens engineering examples in the Baumer manual. Confirm the intended RT/IRT setup and profile in the installed project. Keep part-number differences documented when a machine uses both PROFINET and EtherNet/IP variants. Baumer RT/IRT configuration (PDF) · Baumer Step7 integration note (PDF)
Angle of alignment and commissioning
Commission the shaft clamp and machine datum first. Record the original preset, count direction, scaling and raw turn value before replacement. Follow the chosen telegram and machine procedure to apply an approved preset at a known position. Verify a known movement and restart behavior before releasing the machine. This guide concerns the external position encoder. Baumer commissioning, scaling and preset sections (PDF)
Drawings, pin maps and manuals
- Baumer EAM580-BAC.5YPT.14160.A exact record. Technical data, drawings, GSDML and approved downloads.
- Baumer EAx580 PROFINET manual (PDF). Connector assignment, LEDs, setup and machine-position parameters.
- Baumer EAx580 application note (PDF). Device profiles and GSDML usage.
- Baumer 5YEN EtherNet/IP variant. Separate interface and configuration files.