Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
An approved incremental test input can check A/B phase, count and index with the correct HTL-P voltage rating and loading. Check the actual Mitchell incremental adapter and input specifications before hookup. Use the drive's documented procedure for any running test.
Baumer EHOG860-E16100012/10 Heavy-Duty HTL-P Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is EHOG860-E16100012/10. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| EHOG860-E16100012/10 · 11736714 | 16 mm G7 blind hollow shaft. Retained with a central screw. 1 m cable with open end. | 1,024 pulses per turn, HTL-P line driver, complementary K1/K2/K0. |
| EHOG860-S11100032 | Related EHOG860 configuration. Match the shaft and exact mechanical drawing. | Confirm pulse count, output stage and termination from the exact variant sheet. |
Production and end-of-life status
Baumer publishes an exact data sheet for article 11736714 dated 4 May 2026. Confirm exact production and availability with Baumer when ordering.
Specifications
| Parameter | Value and scope |
|---|---|
| Shaft | Ø16 G7 blind hollow shaft, central screw. Size Ø90 mm, length 72 mm in the exact sheet. |
| Power | 4.75–30 V DC, up to 100 mA without load. Baumer specifies output voltage follows supply for this build. |
| Signal | 1,024 pulses/rev, typically 90° phase shift. K1, K2 and K0 with inverted outputs, HTL-P power line driver. |
| Connection | 1 m factory cable with open end. Use the colour table and overbar notation in the exact PDF. |
| Mechanical speed | Up to 6,000 rpm mechanical. Respect the separate signal frequency, receiver and installation limits. |
| Environment | IP66 and −40 to +100 °C in the exact-ID sheet. Apply the installation conditions. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
The machine shaft engages the 16 mm blind bore and the central screw retains the encoder. The torque support anchors the housing while accommodating the specified motion. Check shaft engagement, seating and support geometry using the drawing and blind hollow-shaft instructions.
Inspect the retaining hardware, stator restraint and cable strain only after isolation. Verify the actual fastening hardware and the matching Baumer procedure before loosening or retorquing it.
Interface and measuring method
K1 and K2 report speed and direction through quadrature. K0 provides the reference pulse. Each track has its own inverse output. A receiver can read a good phase sequence while still missing K0, or can miscount when thresholds and complementary wiring do not match the configured input.
Verified wiring
Use page 2 of the exact Baumer sheet for the factory one-metre open cable. The paired colours below identify each track. Use the overbars in the original table to confirm the normal and inverted conductors before termination.
| Function | Colour or pair |
|---|---|
| Supply / 0 V | Red / blue |
| K1 pair | White and brown |
| K2 pair | Green and yellow |
| K0 reference pair | Grey and pink |
Keep the receiver rated for the configured supply-dependent HTL-P output. The field junction is wired from the actual machine diagram.
Cables inside the motor and at the machine
The named build ends in a fixed one-metre factory lead. Check the exact receiving terminal or junction and select a shielded extension designed for the output, frequency and run length. Match shield and earthing practice to the drive documentation. Baumer's quoted maximum length is conditional on signal frequency and the documented cable arrangement.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No pulses or all channels weak | Check supply under load and confirm that the input accepts the actual HTL-P level. |
| One channel intermittently drops | Check the factory lead and isolated extension. Compare both sides of the differential pair at the receiver. |
| Direction wrong or reference missing | Check K1/K2 phase order and the K0 pair against the correct output diagram. |
| Fault correlates with rotation or load | Check the isolated retaining screw and torque support, shaft fit and cable strain. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Baumer identifies EHOG860 as feedback for demanding machinery and asynchronous drives. The exact build is a speed and incremental position device with a reference pulse. Match the machine's signal configuration and mounting and confirm separately whether it has a safety function.
Angle of alignment and commissioning
Record the mechanical reference and K0 relationship if homing depends on it. After fitting, verify direction and reference capture through the machine's permitted test routine. This incremental feedback configuration uses no servo motor memory restore.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Baumer exact terminal and phase tables. Use the overbar notation for polarity.
- EHOG800 blind hollow-shaft quick start. Use the drawing and approved instructions for the installed mechanical build.