Site visit or send-in evaluation
Share the full article and type code, motor shaft size, terminal box photo, receiver model, speed and whether the fault follows movement, heat or a recent installation. Use the enquiry form to share the details.
What specialist testing can show
A specialist can use a correctly rated HTL receiver or a differential measurement setup to compare K1, K2, K0 and their complements, check the count over a known turn and detect a loaded voltage drop. Mitchell’s TI-5000JX manual covers generic quadrature. Match any tester or adapter to the HTL signal levels before connecting. A stand-alone pulse check and a guarded motor run answer different questions. No exact TI-3000JX run profile for this external tacho assembly was verified. Mitchell generic quadrature test reference · Baumer exact output ratings (PDF)
Baumer HOG 10 DN 1024 I HTL Encoder technical reference
Find your part number
The reference part is article 11070326, marked HOG10 DN 1024 I SR 16H7 KLK. Its data sheet ties 1024 PPR, the Ø16 mm blind bore, HTL-P and radial terminal box to that full code. Read the plate and match the complete code before using the terminal or mounting table.
| Article / type | Output and connection | Mechanical scope |
|---|---|---|
| 11070326 · HOG10 DN 1024 I SR 16H7 KLK | 1024 PPR, HTL-P with complementary signals, radial terminal box | Ø16 mm blind hollow shaft. Use standard radial terminal drawing. |
| HOG 10 G | Twin-encoder family. Read each output section and full code. | Different assembly and ordering options. Use the correct two-channel drawing. |
| HOG10 DN 2048 I LR 16H7 + FSL2 | 2048 PPR and integrated centrifugal switch | Different assembly. Verify switch and feedback independently. |
The HOG 10 family also offers different signal stages, including TTL/RS422 on documented variants. Confirm both the output and the receiver before swapping a unit. Exact HOG 10 article (PDF) · Baumer HOG 10 G · FSL2 combination (PDF) · Related HOG 10 family variants
Production and end-of-life status
Baumer lists article 11070326 with current documentation. Ask Baumer to confirm manufacturing, availability or an approved successor by article number. Reviewed 7 November 2026. Baumer exact article record
Specifications
| Parameter | Value |
|---|---|
| Measuring method | Optical incremental with 1024 pulses per mechanical revolution |
| Supply and output | 9–30 V DC, ≤100 mA without load. HTL-P line driver. |
| Channels | K1 and K2 quadrature with complements. K0 zero pulse and complement. |
| Electrical frequency and length | ≤120 kHz output. Baumer lists up to 350 m at 100 kHz for the stated HTL-P conditions. |
| Fit and speed | Ø16 mm blind hollow shaft, Ø105 mm flange, ≤6000 rpm mechanical. |
| Environment | IP66 and −40 to +100 °C for the documented article. |
At 1024 PPR, a controller using all four A/B edges may count 4096 transitions per turn. Set the receiver’s counting mode and speed limits to the actual application. Baumer 11070326 specifications (PDF)
Mounting and fit
The blind bore slides over the prepared motor shaft and the central retention holds the rotating encoder shaft. The torque arm restrains the housing without adding play or binding the swivel joints. Check the locating shoulder, radial runout and arm geometry before installing a spare. Housing rocking can create angle errors even when the signals are electrically clean.
Baumer’s radial-terminal-box instructions show a Ø16 mm mating shaft, a shoulder diameter of at least Ø20 mm and 40–52 mm insertion dimension for that documented geometry. Section 5.5 specifies 6 N·m for its blind hollow-shaft fastening. The tapered version has its own torque. Section 5.7 recommends 0.03 mm shaft runout where possible. Fit the correct arm length and keep the joints free of play. Blind hollow-shaft dimensions (PDF) · Mounting torque and arm geometry (PDF)
Interface and measuring method
The optical tracks produce two quadrature pulse trains and an index. The drive or counter uses pulse frequency for speed and the sequence of K1 and K2 for direction. Read each line against its complement on a receiver rated for HTL. The K0 pulse gives one repeatable reference each turn. Absolute machine position comes from the machine’s referencing or position management.
Verified wiring
| Terminal marking | Purpose |
|---|---|
| +Uᵦ / 0 V | DC supply and return. Measure across these two terminals. |
| K1 / K1 complement | First quadrature channel and inverted signal. |
| K2 / K2 complement | Second quadrature channel and inverted signal. |
| K0 / K0 complement | Index and inverted index. |
| Cable screen | Use the terminal-box gland and bonding arrangement in the installed wiring plan. |
Use the marked terminals and the view X drawing. The EMS option has a separate terminal assignment. Use a qualified shield and reference arrangement rather than bridging 0 V to the housing. In section 7.6 Baumer specifies 1–3 kΩ for HTL and a separate 120 Ω for TTL. Confirm the actual receiver termination for this installation. Standard and EMS terminal assignments (PDF) · HEK 8 and termination (PDF)
Cables inside the motor and at the machine
| Identifier | Application |
|---|---|
| HEK 8 | Baumer shielded sensor cable family for the radial terminal box. Terminate the drive end to the exact receiver drawing and confirm length. |
| 11043628 / 11004078 | Baumer M6 torque arms in 67–70 mm / 120–130 mm configurations. Mechanical accessories. |
This is an externally mounted motor encoder. The encoder end is the marked terminal box rather than a standard in-motor PCB lead. Use shielded twisted pairs, maintain the gland seal and strain relief, and keep the run clear of power wiring. Baumer HEK 8 accessory · Torque-arm ordering and configuration
Fault checks
Before opening the terminal box or touching the torque arm. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
- Inspect. Check the cable gland, cover seal, loose ferrules, conductive debris, moisture and damaged insulation. Check mounting fit, shaft retention and torque-arm play. Look for contact marks or evidence that the housing has rocked.
- Continuity and shorts. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics.
- Check the supply at the load. A qualified technician using an approved breakout fitted while off can measure DC across +Uᵦ and 0 V. Compare it with the source while connected and within the exact rating. On a long run, check loaded drop and termination before replacing the encoder.
- Compare both ends. Clean K1/K2 at the box and bad counts at the drive suggest a cable, noise, termination or input issue. Loss at both ends with correct supply and fit suggests a feedback fault. A single lost index calls for testing K0 and the receiver’s homing logic. Repeating speed error after remounting calls for inspecting shaft runout and the torque arm.
Motor and drive applications
The blind-hollow-shaft article mounts on a compatible Ø16 mm motor or machine shaft and feeds an HTL-rated drive or industrial counter. Match shaft shoulder and length, torque-arm placement and required protection. OEM motor model compatibility requires the motor and installation drawing.
Angle of alignment and commissioning
Set the machine’s reference and feedback direction after mounting. Record the existing PPR, input mode and any K0-to-machine datum before removal. Verify speed scaling and homing with the approved commissioning procedure. On this external tacho the normal mechanical setup is shaft and housing alignment. A separate servo commutation offset belongs to its own feedback system.
Drawings, pin maps and manuals
- Baumer 11070326 data sheet (PDF). Electrical ratings, blind-shaft dimensions and standard terminals.
- Baumer HOG 10 / HOG 10 G radial terminal-box instructions (PDF). Sections 5.3–5.7 for mounting and 7.1–7.6 for output, terminals and cable.
- Baumer 11070326 catalogue entry. Lists the exact item and mounting accessories.