Identify the fitted part
| Guide scope | Bosch SR digital resolver — Motor application |
|---|---|
| Feedback identity | Record the fitted feedback maker and complete designation; the named motor family is not a sensor part number. |
| Manufacturer MPN / full suffix | SR digital is the scoped family/designation. Match every additional character on the fitted label before ordering. |
| OEM service ID / motor order | Not established for a specific fitted unit. Record the full motor label, feedback option and any OEM service ID separately. |
| Interface | Digital resolver interface |
| Documented starting connection | TI-5679, 17-contact M23; exact electronics/profile to verify |
| Material distinction | TCG245 covers SF EnDat; TC366 covers SD/SE Hall/tach. SR is a distinct documented branch. |
Specialist testing: connection before conclusion
| TI-5000JX bench scope | Admission establishes a named SR digital-resolver connection. Obtain electronics, power and test-profile documentation before specifying a test procedure. |
|---|---|
| Starting lead / fixture | TI-5679, 17-contact M23; exact electronics/profile to verify |
| Profile / module | Exact digital-resolver setup remains to verify; TI-5679 is connection evidence only. |
| TI-3000JX motor-run scope | No complete motor-run approval established by this proposal. Verify motor poles, power/brake wiring, alignment, fixture and the installed TI-3000JX profile. |
The admission evidence is Mitchell Test Cable Index by Manufacturer Support — PDF page 3, TI-5679 row. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.
Production and replacement status
Current production status, exact-order stock and an approved successor have not been confirmed in the cited evidence. Retain the installed label and ask for an exact-order check before selecting a replacement.
Specifications and interface
| Verified technical boundary | Identify the SR digital-resolver interface and electronics before selecting a passive-resolver procedure. |
|---|---|
| Supply / output compatibility | Use the complete fitted label and its wiring drawing. No universal supply, receiver level or excitation is assigned to this family guide. |
| Exact dimensions, torque and pins | Use the scoped drawing or request it through the enquiry. Values from another suffix, connector view or motor revision are not substituted. |
Digital resolver is the index description for this Bosch SR connection. The available row does not define the internal electronics, output encoding, supply or excitation. Establish the fitted device and its electrical drawing before choosing any powered test.
Mechanical fit and retention
Photograph the incoming shaft/coupling position, locating seat, restraint, fasteners and cable exit before removal. Check accessible looseness, contamination, bearing roughness and signs of rubbing after isolation. Identify whether the assembly has its own bearings, a hollow-shaft clamp or a motor-retained sensor; the exact drawing controls that decision. Do not lever against a sensing disc or apply a torque from a similar-looking model.
The index calls this a Bosch SR digital resolver and lists TI-5679 at 17-contact M23. That is connection evidence only. It does not establish a passive resolver excitation, a generic J12 setup, a supply voltage or a supported electronics profile.
Wiring and connector boundaries
Map five boundaries separately: the sensor plug or PCB, internal motor loom, motor bulkhead, external machine cable and drive/tester end. Record connector gender, keying, contact numbering and whether the drawing shows mating or termination side. The documented Mitchell lead is a starting fixture, not a pin map for a handmade adapter. Keep power, temperature, brake, shield and feedback contacts identified individually.
Starting connection for this guide: TI-5679, 17-contact M23; exact electronics/profile to verify. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.
Internal loom and machine cables
No internal OEM harness number or universal extension has been verified for this exact fitted order. Obtain the motor assembly drawing and photograph both loom ends before sourcing it. A fixed installation cable and a cable-carrier extension may have different flex and shielding requirements. Do not convert the Mitchell test-lead number into an OEM replacement part number.
Practical fault checks
Isolation and measurement conditions
Secure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.
| A passive-resolver fixture has been proposed for an SR unit | Stop setup selection until the electronics and interface drawing are identified. TI-5679 and the M23 housing alone do not establish excitation or a supported profile. |
|---|---|
| Fault follows cable movement | Under the site isolation procedure, inspect connector engagement and the loom. Electrical continuity testing needs the actual disconnected harness pin map. |
| No position response | Record exact labels and drive alarms. Confirm the correct supply, receiver and approved test configuration before energizing or condemning the feedback. |
Alignment, reference and memory
Preserve the original motor and feedback positions and any recoverable configuration. Neither a passive-resolver alignment recipe nor an electronic offset procedure is established for this SR digital-resolver entry. Obtain the exact Bosch procedure and verified tester setup first.
Motor and drive applications
SR digital resolver. TCG245 covers SF EnDat; TC366 covers SD/SE Hall/tach. SR is a distinct documented branch.
A matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.
Drawings, manuals and evidence
- Mitchell Test Cable Index by Manufacturer Support — PDF page 3, TI-5679 row
Exact OEM technical PDF remains to obtain. The Mitchell reference establishes only the documented device or motor/feedback connection; it does not fill missing ratings or pins.
Common questions
What should accompany a SR digital resolver enquiry?
Send clear photographs of the motor and feedback labels, every suffix/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.
Can the listed Mitchell lead be used as a replacement machine cable?
The lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.
Does a successful feedback bench test prove that the motor can be run?
No complete motor-run approval established by this proposal. Verify motor poles, power/brake wiring, alignment, fixture and the installed TI-3000JX profile. A complete run assessment also checks motor power, brake, protection and mechanical conditions.
When does a site visit or send-in evaluation make sense?
A site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.
Request a scoped service evaluation
Use the existing encoder enquiry form with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.