Site visit or send-in evaluation
Share the feedback label, complete motor or machine order, drive model and alarm. Include both connector faces and note whether the issue followed a cable change, replacement or mechanical work.
What specialist testing can show
TI-5000JX bench. Mitchell documents the hybrid connection and cautions about incomplete memory decoding.
TI-3000JX motor run. Exact motor run setup open
B&R 8LSAA2.D8045S000-3 Hybrid EnDat22 Motor Feedback technical reference
Find your part number
Use the full fitted label. A motor order identifies the assembly and should be recorded separately from an encoder part number.
| ID or order code | Identification and scope |
|---|---|
| 8LSAA2.D8045S000-3 | Exact B&R single-cable motor order. |
| ECI 1119 FS | B&R names this inductive singleturn EnDat22 encoder family for the order. Record the fitted encoder ID. |
| S0 / S1 / S2 / S3 | Hybrid connector option examples in Mitchell’s 8LS article. Match the complete order. |
Production and end-of-life status
Confirm current orderability and any successor for the exact ID with the manufacturer or motor OEM. The dated documentation identifies the configuration.
Specifications
| Parameter | Verified scope |
|---|---|
| Motor configuration | B&R lists a single-cable connection and five motor pole pairs for the reference order. |
| Feedback | ECI 1119 FS EnDat22 inductive singleturn feedback on this exact B&R motor order. |
| Hybrid signals | Mitchell describes the serial connection without incremental 1 Vpp A/B through this connector. |
Mounting and fit
Use the B&R order and OEM motor outline to confirm the shaft, connector clearance and mounting. Obtain the full fitted encoder ID and approved installation procedure before disturbing the inductive gap or the feedback safety configuration.
Interface and measuring method
The hybrid cable carries motor power and a separate EnDat link in the same assembly. Verify communications independently from motor windings and cable power. Line Levels testing does not apply to the omitted A/B signals on the hybrid connection.
Wiring and connector scope
Mitchell’s hybrid connector figure identifies the feedback path. Verify the exact motor view and isolate motor power before connecting the tester. Use the corresponding encoder diagram for direct access.
Cables inside the motor and at the machine
TI-5786 mates with the documented 8LS hybrid connection. TI-5668 or TI-5079 may apply when connecting directly to a matched encoder. Verify the installed hybrid cable assembly with B&R.
Fault checks
Before inspection. Follow the site’s isolation and lockout procedure. Secure any load against movement, allow the specified discharge time and have a qualified technician verify isolation. Check resistance on a disconnected harness at both ends. Use the documented shield and return connections.
| Observation | What to verify |
|---|---|
| Drive sees motor power but no encoder | Check the serial path within the hybrid cable and the exact drive and motor code. |
| Reported memory angle conflicts with incoming measurements | Retain the original file and physical measurements. Verify the OEM commissioning procedure. |
| Feedback reads after fitting but the drive faults | Check approved gap, reference, mounting and safety validation separately. |
Motor and drive applications
8LSAA2.D8045S000-3 Check the exact ID, drive and connector before applying an installation or test procedure.
Identify the hybrid path and check the exact motor memory rules. Keep this application distinct from the existing ECI 1119 device guide.
Angle of alignment and commissioning
Capture the incoming alignment and memory before removal. Mitchell flags incompletely decoded memory fields on the newer hybrid series. Use the OEM service and safety validation procedure for the installed drive and feedback option.
Drawings, pin maps and manuals
- B&R 8LS hybrid guide. Article body. S options, TI-5786 and memory interpretation.
- B&R 8LSAA2.D8045S000-3 product record. Motor data, single-cable connection and exact encoder family.