What specialist testing can show
TI-5000JX bench. Read absolute data and verify the separate analogue tracks where present.
TI-3000JX motor run. Confirm the full motor order, power lead, phase reference and supported TI-3000JX setup.
Starting lead. TI-5690 on the documented 17-contact M23 EnDat branch. Check the actual EC/FC drawing.
Control Techniques Unimotor fm EC / FC EnDat 2.1 Servo Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| Unimotor fm EC / FC | EC is EQI 1331 multiturn. FC is ECI 1319 singleturn. Confirm the motor and exact encoder ID. |
| EF / FF and GB / HB | The cited OEM table lists separate EnDat22 options. Match the connector and drive. |
| CT-Coder | Separate feedback selection with its own setup. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Serial interface | EnDat 2.1 / EnDat 01 for EC and FC. |
| Analogue tracks | 32 sine/cosine periods per turn in the cited EC/FC table. |
| Feedback supply | 4.75–10 V DC for the documented options. Use the approved motor-side connection. |
| Turn field | EC has 4,096 turns in the cited table. FC is singleturn. |
Interface and measuring method
The drive reads position through EnDat and uses the analogue tracks where required. Assess serial position, the turn format and analogue movement independently.
Mounting and fit
Use the actual frame and fitted encoder drawing. Check the locating seat, rotor fastening and specified sensing gap. Record the cable exit and received reference.
Wiring and connector scope
The contact groups below apply to the manufacturer’s 17-contact SI motor-end EC/FC column. Confirm the connector drawing and viewing side before wiring.
| Contact or circuit | Documented scope |
|---|---|
| 1 and 2 | Thermistor pair. |
| 8 / 9 | Clock + / −. |
| 11 / 12 | Data + / −. |
| 10 / 13 | Cosine + / −. |
| 14 / 15 | Sine + / −. |
| 16 / 17 | Feedback supply / 0 V. |
| Connector body | Screen. Follow the applicable wiring figure for shield termination. |
Internal motor and machine cables
Use the OEM SI cable order key and drive type for the production assembly. Record the internal encoder lead separately from the TI-5690 test fixture.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Serial position present, analogue fault | Trace the documented sine and cosine pairs separately. |
| Unexpected turn count | Compare EC and FC and confirm drive format. |
| No response after cable change | Check the SI connector view, supply and clock/data pairs. |
Angle of alignment and commissioning
Save the original motor reference and direction and any position data needed by the drive. Verify the fitted encoder and phase convention before commissioning.
Motor and drive applications
Unimotor fm with EC or FC and the documented 17-contact M23
Choose EC versus FC and distinguish EnDat 2.1 from EnDat 2.2-only and CT-Coder options.
Related SpareFaber guides
Drawings, pin maps and manuals
- Mitchell Test Cable Index by Manufacturer Support. Control Techniques Support Part Numbers, TI-5690. OEM Unimotor fm EC/FC motor-end signal table.
- Control Techniques Unimotor fm, feedback order and pin tables. Supplementary reference for the stated model or setup.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation