Site visit or send-in evaluation
Share the housing and module labels, PPR, wheel code, photos of the connector and motor face, drive model and the speed at which pulses drop out. Note whether a sensor or wheel was replaced recently. Use the enquiry form to share the details.
What specialist testing can show
A guarded fixture with the correct wheel and sensor lets a technician check differential A/B, count and direction, optional Z and the available alarm. Compare both outputs on a dual-channel build using the documented isolated supplies and receiver inputs. Mitchell describes a TI-5000JX Generic Incremental Encoder test method. Use a documented adapter or receiver matched to the RT8 signal levels before connecting. Standalone RT8 compatibility and an RT8-specific TI-3000JX run profile require confirmation. Mitchell generic quadrature test method · Dynapar electrical ratings (PDF)
Dynapar NorthStar NexGen RIM Tach 8500 RT8 Encoder technical reference
Find your part number
Record the full RT8 number and the installed wheel and sensor module labels. Page 8 of the installation manual decodes PPR, index, wheel size or end-of-shaft adapter, single or dual output and termination. The word 8500 appears on both legacy and NexGen material.
| Name or full order number | Pulses and index | Wheel / connector |
|---|---|---|
| RT81024LF082Q | 1024 PPR. L means no index. Code 2 specifies dual output. | F08 end-of-shaft 2⅜ in configuration. Q denotes latching connector on an 18 in cable. |
| RT82048ZV071C | 2048 PPR. Z specifies index. Code 1 specifies single output. | V07 1⅛ in bore. C denotes the latching connector with ½ in NPT. |
| RIM Tach 8500 / 8500 Quad (legacy) | Read original label and legacy order table. | Legacy manual specifies a 5–15 V supply at the connector. Pin 5 is unassigned in its wiring table. |
1024 PPR exact record · 2048 PPR exact record · RT8 order and outline (PDF) · Legacy wiring (PDF)
Production and end-of-life status
Dynapar marks the original RIM Tach 8500 discontinued and identifies the NexGen RT8 as its successor. Dynapar lists RT8 product configurations and a legacy wheel/sensor upgrade kit. Match the original face, wheel, PPR, termination and voltage before selecting an upgrade. Reviewed 7 November 2026. Dynapar legacy 8500 lifecycle notice · NexGen RT8 product page · Dynapar NRTK upgrade kits
Specifications
| Parameter | Value / condition |
|---|---|
| Measuring method | Bearingless magnetic incremental with differential line-driver outputs |
| Power | 5–26 V DC in the exact RT8 product records and ratings. Typical 95 mA per module plus line-driver load. The manual pin table prints 5–24 V at Vcc. Confirm the exact nameplate and installation revision before using a supply above 24 V. |
| Frequency and shaft speed | 180 kHz data/index frequency limit and 7,000 rpm mechanical maximum. The installed PPR and receiving input can set a lower usable speed. |
| Mount and shaft runout | NEMA 8.5 in 180C face. Maximum shaft runout 0.005 in TIR in the NexGen manual. |
| Documented radial gap | For ≤1200 PPR, 0.075 in +0.015/−0.070 in. For >1200 PPR, 0.050 in +0.015/−0.040 in. Use the matching assembly procedure. |
| Environment | −40 to +100 °C operating. The sealed latching connector is listed IP65. |
Calculate pulse frequency as PPR × shaft rpm ÷ 60. A 2048 PPR wheel at 6000 rpm would produce 204.8 kHz, above the documented 180 kHz limit. Use both limits and the drive input specification when commissioning. NexGen ratings (PDF)
Mounting and fit
The pulse wheel rotates on the motor shaft. The sensor module fits in the stationary C-face housing. Check the actual wheel style first. A through-shaft clamp and an end-of-shaft adapter have separate installation instructions. Seat the housing squarely on the face, then position the wheel axially under the sensor before securing it.
In the illustrated through-shaft procedure, the front face of the wheel aligns with the indicated cover surface. The four wheel-clamp screws are tightened in a star pattern to a nominal 35 in·lbf for that assembly. End-of-shaft adapters use a different procedure in the manual. Verify the actual kit and mounting drawing before using a torque. Check for axial migration, shaft runout, rubbing and a fully seated sensor if pulses disappear once per revolution. Through-shaft procedure (PDF) · End-of-shaft procedure (PDF)
Interface and measuring method
The drive or counter measures pulses as the magnetic wheel passes the sensor. The lead/lag relationship of A and B gives direction. On the documented RT8, A leads B for counterclockwise motion as viewed from the male C-face end. Differential receivers use each channel with its complement. Z provides a repeatable index on builds that have that option. It does not supply absolute position after power loss.
Verified wiring
| Signal | Latching pin | MS pin | Factory pigtail |
|---|---|---|---|
| 0 V common | 1 | A | Black |
| B / B complement | 2 / 7 | E / H | Green / yellow |
| A / A complement | 3 / 8 | D / G | Blue / gray |
| Z / Z complement, if fitted | 4 / 9 | C / I | Violet / orange |
| Alarm, if fitted | 5 | F | Unavailable on the plain pigtail option |
| Vcc | 6 | B | Red |
| Shield | 10 | J | Braid |
Identify terminals by the housing marks and manual view. Compare the receiver’s input type and voltage limits. Keep unused outputs insulated individually and follow the grounding arrangement for the actual installation. The legacy pin-5 assignment is separate. NexGen connector table (PDF) · Legacy connector table (PDF)
Cables inside the motor and at the machine
The RT8 attaches to the motor face and uses an external sensor-to-drive cable. The order termination code selects the matching latching or MS connector, plain pigtail, or connector-on-lead configuration. Q is the 18 in latching lead configuration in the documented example. The C and F orders differ in mating-connector provision. Read the actual code before ordering a mating hood or cable.
Use a shielded cable with the documented pair grouping. Keep the cable away from motor leads. Confirm the exact mating accessory number, cable length and termination for the installed receiver and environment. RT8 connector ordering (PDF) · Replacement wheel and sensor families
Fault checks
Isolate the machine and secure the shaft. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
- Inspect. Check hood retention, damaged or pushed-back contacts, conductive dust, oil, cable support and the sensor seating. Check that the wheel clamp has not moved on the shaft.
- Isolated cable tests. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics.
- Supply and outputs. With an approved breakout fitted while off, a qualified technician can measure DC between 6 and 1 on the latching map. Compare the module and receiver ends under load. Read the RT8 LED against the manual and compare pulses with a suitable differential scope or counter. A steady green at rest differs from flashing green with wheel motion.
- Locate the fault. No pulse at the module despite correct power and motion calls for wheel, gap and sensor checks. A clean module signal and a poor drive signal point to the cable, input setting or interference. A loss at high speed calls for checking calculated pulse frequency. A repeatable once-per-turn dropout points toward wheel position or runout.
Motor and drive applications
Dynapar specifies the 180C motor face for AC and DC motor velocity and position feedback. The F44, F47, F60 and F68 end-of-shaft wheel codes are tied to the motor series listed in the RT8 manual. Confirm the exact motor and shaft before selecting a wheel. Dynapar motor applications · Wheel order codes (PDF)
Angle of alignment and commissioning
The normal setup for this external speed encoder is mechanical wheel alignment and receiver direction, PPR and index verification. If the machine uses the index as a datum, record its required relation to the mechanism before moving the wheel. Complete the machine’s homing and speed feedback checks after replacement. Any separate servo commutation alignment follows its own motor and drive procedure.
Drawings, pin maps and manuals
- NexGen RT8 installation instructions 702869-0001 (PDF). Page 1 wiring and limits, pages 4–7 assembly, page 8 ordering and dimensions.
- Legacy 8500 and 8500 Quad manual (PDF). Use for the older supply, pin assignments and wheel instructions.
- Dynapar RT8 product and resource page. Catalogue links to the series data sheet and additional wheel instructions.