Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A correctly rated counter or oscilloscope can measure both differential quadrature pairs and the index with the receiver loaded as specified. For Mitchell use, verify the configured incremental profile, supply, adapter and input ratings for the HV stage. Verify a run fixture separately for the actual motor.
Encoder Products Company 25T-11SJ-1024NV1RHV-SMX-S3 Incremental Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is 25T-11SJ-1024NV1RHV-SMX-S3. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| 25T-11SJ-1024NV1RHV-SMX-S3 | Through bore, 5/8 inch, SJ tether arm and S3 seal option. | 1,024 cycles per rev, V1 supply, quadrature with index, HV line driver, SMX 10-pin MS. |
| 25T-11SJ-1024NV1ROC-SMY-S3 | Same coded bore, tether and seal. Inspect the fitted connector and body clearance. | OC open collector and SMY seven-pin MS. A different receiver circuit and wiring column apply. |
Production and end-of-life status
EPC documents the Model 25T/H family and the exact order code is catalogued by a distributor. Confirm production and orderability for this suffix directly with EPC.
Specifications
| Parameter | Value and scope |
|---|---|
| Bore and tether | Code 11 is 0.625 inch (15.875 mm). SJ is the slotted tether for the listed bolt-circle range. See the order table. |
| Output | 1,024 electrical cycles per revolution. R adds index to the A-leading-B quadrature convention shown by EPC. |
| Supply | V1 is 5–28 V DC. HV is the line driver from the 5–28 V input/output group. Match receiver voltage tolerance. |
| Connector | SMX is 10-pin MS. Use the separate 10-pin MS wiring column for this encoder. |
| Seal | S3 is IP66 per model sheet. Check the associated operating limits and connector seal for the machine. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Support the encoder by the specified bore and clamp on the motor shaft. Fit the SJ tether to the documented motor bolt circle. The tether restrains housing rotation while accommodating the permitted shaft motion. Keep it free of preload or contact with the rotating assembly. Check the shaft runout and axial movement against the manufacturer limits and use TB-540 for the exact mounting sequence.
After safe isolation inspect clamp seating, tether hardware, abrasion, radial runout and connector clearance. Use the torque and fit details in the applicable installation drawing.
Interface and measuring method
Optical tracks generate A and B square waves offset in phase and an index Z. The receiver uses phase order for direction and the quadrature decoding mode to decide how many edges it counts. At four-edge decoding, 1,024 cycles yield 4,096 counts per turn. Match the HV line driver's electrical levels and the actual drive input before interpreting pulse shape.
Verified wiring
EPC's Model 25T/H data sheet page 2 gives a separate column for the 10-pin MS connector used by SMX. Read the moulded contact letters using the connector drawing. The 10-pin bayonet is a separate termination.
| Function | Device contact letters |
|---|---|
| Power and common | D +VDC, F common |
| A and inverted A | A, H |
| B and inverted B | B, I |
| Z and inverted Z | C, J |
| Case | G |
Confirm the plug's shell and unused contacts from EPC. Match each complementary pair at the receiver and inspect any shield connection separately.
Cables inside the motor and at the machine
Use an EPC-approved 10-pin MS mating cordset for the SMX build and a receiver end verified against the machine drawing. Request the cordset by the installed encoder ID, length, orientation and motion duty. The datasheet cable colours apply to the gland cable option and provide no identification of a machine's SMX loom.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No count | Compare documented supply and common at the encoder. Then verify output type and both sides of each A/B pair. |
| Wrong direction or a factor-of-four scaling error | Check phase order, inverted complements and the controller's edge-counting mode. |
| Index absent | Check Z and its inverse at SMX contacts C/J and verify the index capture setting. |
| Pulse fault at speed or vibration | Inspect tether and clamp, then check cabling, receiver thresholds and waveforms at relevant speed. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
This exact 25T build can be used on motors or driven shafts that match the bore, tether, receiver and environment. The hardware is an incremental position and speed sensor. Consult the motor documentation when the machine also requires an independent commutation reference.
Angle of alignment and commissioning
Record shaft index position before removal when machine homing uses it. After fitting verify A/B direction, Z capture and homing against a known datum. The exact incremental unit has no motor memory to copy. Apply any commutation adjustment only through the documented motor and drive procedure.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Exact order reference. Distributor catalog entry, cross-checked against the manufacturer order key.
- EPC TB-540 installation guide. Check the model coverage, shaft retention, tether and separate wiring table.