What specialist testing can show
TI-5000JX bench. Check feedback and commutation on the qualified connector after verifying the actuator and motor drawing.
TI-3000JX motor run. Confirm approved drive and actuator test arrangement and secure the load and stroke before powered motion.
Starting lead. TI-5684 on the scoped 17-contact M23.
Exlar / Curtiss-Wright GSM MCM ABZ/UVW Linear Actuator Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| GSM MCM | Scoped TI-5684 17-contact M23 branch. Verify the motor and actuator nameplates. |
| GSM family | Legacy linear actuators with fitted feedback and amplifier choices. Compare the exact order and original configuration. |
Production and end-of-life status
Curtiss-Wright classifies GSM as a legacy series. Check the fitted order and service information for the actuator and motor configuration.
Specifications
| Parameter | Verified scope |
|---|---|
| Motion | Incremental ABZ position and reference on the named feedback connection. |
| Commutation | Separate UVW on the scoped test branch. |
| Fixture | TI-5684, 17-contact M23, with the exact actuator connection verified. |
Interface and measuring method
The encoder and commutation signals describe motor motion. An actuator fault can also arise in the mechanism or the drive configuration. Compare the motion symptoms and alarm history with the received feedback data.
Mounting and fit
Use the Exlar service manual and the fitted actuator order before opening the unit. Secure the load and retain the original mechanical reference and travel settings.
Wiring and connector scope
Match the MCM connector view, encoder supply and ABZ/UVW before choosing a test. Identify any limit, brake and motor circuits separately.
Internal motor and machine cables
Record the actuator-side harness and amplifier cable part numbers. Inspect strain relief and isolate-test the actual cable before assuming a feedback unit has failed.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Counts change but the load fails to move correctly | Check the approved mechanism and drive diagnostics alongside feedback. |
| Drive faults on enable | Check commutation and the original amplifier setup. |
| Feedback dropout only at part of the stroke | Inspect cable movement and the correct connector. |
Angle of alignment and commissioning
Save the original motor file, reference, travel limits and direction. Use the approved actuator procedure with restrained load and controlled stroke for any powered checks.
Motor and drive applications
Exlar GSM linear actuator, documented MCM 17-contact M23 option
Separate an encoder or loom fault from an actuator mechanism or drive setup issue.
Drawings, pin maps and manuals
- Mitchell Test Cable Index by Manufacturer Support. Exlar and Danaher rows, TI-5684 GSM MCM
- Curtiss-Wright Exlar GSM series actuator manual, 29959 rev V. Supplementary reference for the stated model or setup.
- Exlar GSM legacy product page. Technical downloads and service information for the actuator family.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.