What specialist testing can show
TI-5000JX bench. Mitchell’s TI-5000JX manual lists B2 behavior. Choose the connector-matched legacy serial profile.
TI-3000JX motor run. TI-3000JX P6 or P8 A/B/B2 selection for the documented motor arrangement.
Starting lead. TI-5004, TI-5005 or TI-5006 by fitted legacy FANUC connector.
FANUC Pulsecoder B2 Legacy Serial Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| Pulsecoder B2 | Legacy FANUC encoder identified in both Mitchell manuals. Confirm the complete A860 part and actual connector. |
| P6 A, B and B2 | Mitchell run selection for the documented six-pole motor setup. |
| P8 A, B and B2 | Separate run selection for the documented eight-pole motor setup. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Position behavior | Mitchell describes absolute count within a turn on power-up for the A/B/B2 branch. |
| Commutation | The run fixture derives commutation from the position count. The actual pole count matters. |
| Connector scope | Legacy FANUC branches can use round MS or DB15. Match the fitted plug and drawing. |
Interface and measuring method
The legacy serial frame supplies position. The run tester uses this position to generate commutation with the appropriate pole selection. If the test shows the wrong angle, verify the motor and setup as well as the encoder.
Mounting and fit
Use the complete motor and Pulsecoder orders to obtain the rear assembly and coupling drawing. Record the fitted shaft reference, cover and cable exit before disturbing the encoder.
Wiring and connector scope
Choose the connector-matched FANUC cable sheet. TI-5004, TI-5005 and TI-5006 are listed for the A/B/B2 run family. Verify supply, data and other contacts using the exact drawing.
Internal motor and machine cables
Separate the short test cable from the original motor-to-drive lead. Use the fitted motor and amplifier labels to identify the cable and internal harness.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Position reads and commutation is wrong | Check six versus eight poles, actual motor order and alignment. |
| No reply on the test fixture | Verify legacy profile, connector and cable before condemning the encoder. |
| Fault follows encoder fitting | Check coupling, seated position and the stored machine reference. |
Angle of alignment and commissioning
Preserve the existing reference and motor pole count. Have a qualified technician verify the installed commutation and axis reference before operation.
Motor and drive applications
Documented six- or eight-pole FANUC motor branches
Record fitted A860, motor order, pole count, drive and connector map.
Related SpareFaber guides
Drawings, pin maps and manuals
- Fanuc Motors, TI-3000JX manual. P6 and P8 A, B and B2 selections
- Mitchell FANUC TI-5000JX manual chapter. Legacy B2 position, index behavior and connector overview.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.