What specialist testing can show
TI-5000JX bench. Use the TI-5000JX resolver method only after confirming the exact excitation, fitted connector and safe breakout.
TI-3000JX motor run. Confirm exact motor poles, resolver speed and the approved fixture for the fitted gearmotor.
Starting lead. KSG R4 dedicated test lead open. Match the actual connector and verified resolver wiring.
Georgii Kobold KSG R4 Resolver Gearmotor Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| KSG with R4 | Resolver option in the Mitchell-linked KSG type code. Read the complete motor, gearbox and connector designations. |
| KSG with RQ | Separate SICK Stegmann option in the linked drawing. Match the actual label before selecting a fixture. |
| KSG 264 D-R4 / PLG70 | Manufacturer example family for dimensional reference. The full ratio and shaft details depend on the order. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Measurement | Passive resolver on the R4 option. Confirm excitation, ratio and winding details for the fitted assembly. |
| Connection | KSG connection drawing is linked by Mitchell. Verify the installed plug and wiring revision. |
| Mechanical scope | Motor and gearbox output dimensions are different references. Use the drawing for the fitted variant. |
Interface and measuring method
The drive supplies an excitation and calculates angle from the sine and cosine returns. On a gearmotor, the resolver position is referenced to the motor shaft. Compare gearbox output position using the documented ratio and mechanical reference.
Mounting and fit
Use the KSG drawing for mounting and gearbox shaft dimensions. Preserve resolver rotor/stator alignment and note any original coupling location before opening the rear assembly.
Wiring and connector scope
Follow the OEM KSG connector drawing for the actual R4 branch. Identify excitation and return pairs separately and verify the shield and any other motor circuits. Confirm a suitable test breakout for the fitted socket.
Internal motor and machine cables
Use the complete motor, gearbox and drive order to select the original harness. Compare the fitted connector and wiring revision. Mitchell lists the KSG connection data, with the exact dedicated test lead open.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
A resolver is passive. Check isolated winding continuity against the matching drawing. Use the specified AC excitation on the approved test fixture for a signal check.
| Symptom | What to verify |
|---|---|
| Both returns are missing | Check excitation and the isolated cable path before judging the windings. |
| Motor reads angle and output position is wrong | Compare gear ratio, coupling and machine reference with the actual motor angle. |
| One return is intermittent | Inspect the corresponding winding circuit, connector and harness independently. |
Angle of alignment and commissioning
Record resolver direction, motor-side angle and original machine zero. A qualified technician should confirm electrical alignment and gearbox reference before return to service.
Motor and drive applications
KSG geared motor with R4 feedback
Obtain the fitted KSG order, resolver specification, connector view and approved breakout.
Drawings, pin maps and manuals
- Georgii Kobold Motors. KSG Type Code and Connections
- Georgii Kobold stainless gearmotor catalogue. KSG mechanical data, feedback option and drawing scope.
- Georgii Kobold KSG R4 CAD references. Manufacturer R4 code and geared-motor dimensions.
- Mitchell-linked KSG order code. R4 resolver and RQ alternatives.
- Mitchell-linked KSG connector drawing. Choose the R4 view matching the fitted build.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.