What specialist testing can show
TI-5000JX bench. Mitchell documents KSY-D options and family lead references. Verify the fitted EnDat profile and analogue period count on the TI-5000JX.
TI-3000JX motor run. Confirm the exact KSY-D motor and approved fixture, including commutation and fitted feedback option.
Starting lead. TI-5079 is a KSY-D family lead listed by Mitchell. Verify the RE/RE-2 plug before using it.
Georgii Kobold KSY-D HEIDENHAIN ECN 1313 EnDat Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| KSY-D RE · ECN 1313 | 13-bit singleturn EnDat and 2,048 incremental periods per revolution per the OEM table. |
| KSY-D RE-2 · ECN 1313 | 13-bit singleturn EnDat and 512 incremental periods per revolution. Compare the original code and actual HEIDENHAIN ID. |
| KSY-D RD / RD-2 · EQN 1325 | Different multiturn options. Read the full motor order before selecting the encoder or drive profile. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Serial position | 13-bit singleturn on the Georgii Kobold RE and RE-2 branches. |
| Analogue incremental | 2,048 periods for RE and 512 for RE-2. A receiver scaled for the other option can show a fourfold error. |
| Motor connection | Choose the OEM KSY-D feedback connector view and actual motor configuration. Mitchell lists multiple cables for the KSY-D family. |
Interface and measuring method
The drive can use the EnDat exchange for absolute angle and the incremental channels for position tracking. The serial position may read correctly even when the incremental scale or signal path is wrong. Test both within the fitted configuration.
Mounting and fit
Use the Georgii Kobold KSY-D frame outline for the motor and the fitted HEIDENHAIN ID drawing for the encoder. Confirm the shaft attachment, stator coupling, screw and cable route under isolation before disturbing the feedback.
Wiring and connector scope
Open the OEM KSY-D connection drawing for the fitted option. Identify the EnDat clock and data pairs, supply and return, and analogue channels. Keep the motor connector and encoder connector views separate.
Internal motor and machine cables
Mitchell’s KSY-D family table lists several test leads, including TI-5079. Confirm the exact option, plug and data path before selecting a fixture. The factory internal lead and machine cable need the full Georgii Kobold order and connector revision.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Serial position reads but the motion scale is wrong | Check RE versus RE-2 and the drive’s incremental period configuration before replacing hardware. |
| Absolute position is missing while analogue movement is visible | Check the EnDat clock/data path and the serial receiver separately. |
| Feedback faults after mechanical work | Inspect the fitted stator coupling, shaft attachment and plug retention under isolation. Check the saved motor reference. |
Angle of alignment and commissioning
Save the existing motor settings and any readable encoder data. Record the commutation reference and actual analogue period count. Verify the OEM alignment procedure and both feedback paths after installation.
Motor and drive applications
Georgii Kobold KSY-D with RE or RE-2 code
Confirm fitted HEIDENHAIN ID, KSY-D order, pin view and actual test and internal cable.
Related SpareFaber guides
Drawings, pin maps and manuals
- Georgii Kobold Motors. KSY-D Encoder Systems, RE and RE-2
- Georgii Kobold KSY-D technical catalogue. Encoder systems table on PDF page 8 and frame/connection drawings.
- Georgii Kobold KSY-D downloads. Manufacturer frame and configuration drawings.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.