Site visit or send-in evaluation
Send the encoder label and complete motor order code, drive model, alarms and the work done just before the fault. For bench diagnosis of a clearance or commutation problem, keep the motor, original encoder and mating loom together. Use the enquiry form to share the details.
What specialist testing can show
A compatible Mitchell TI-5000JX EnDat setup can compare serial position, direction and communication on the correct profile and lead. Confirm the current software profile for this ID. The 810661-02 has digital feedback. For mechanical installation, HEIDENHAIN lists the PWM 21 with ATS mounting interface for the 810661-xx family. Check mounting quality through that documented workflow in addition to reading serial position.
Mitchell describes a TI-3000JX Generic EnDat RunSer method for supported motors. Confirm the motor profile and fixture before using it. Any run test requires verified motor phase order, pole count, direction and commutation, with the motor secured and guarded. Mitchell EnDat test reference · Mitchell serial run-test setup · HEIDENHAIN mounting interface (PDF)
HEIDENHAIN ECI 1319 EnDat22 Encoder technical reference
Find your part number
Read the complete ID and its suffix, then record the motor and drive order codes. This guide focuses on 810661-02 and the documented 810661-xx EnDat22 family. HEIDENHAIN also uses ECI 1319 on an EnDat 3 product sheet. Compare the interface before applying a wiring table.
| Full ID | Shaft and flange | Electrical / order details |
|---|---|---|
| 810661-02 | 44C Ø12.7 mm blind bore, 0YA flange | EnDat22 singleturn, keyed 12+4-pin PCB, D533166 |
| 810661-03 | 44A Ø12 mm blind bore, 0YA flange | EnDat22 singleturn, same document family. Check the smaller mating shaft. |
| 810661-06 | 44C Ø12.7 mm blind bore, 0YA flange | EnDat22 singleturn. Manufacturer lists this ID in a collective package. |
The alternative EnDat 3 E30-R2 product sheet has a different electrical interface. Use the exact ID sheet and hardware configuration for the unit in hand. EnDat22 ID table (PDF) · Separate EnDat 3 product information (PDF)
Production and end-of-life status
HEIDENHAIN provides a current catalogue record for 810661-02. Exact-ID production, stock and last-time-buy status require confirmation from the manufacturer. Reviewed 7 November 2026. 810661-02 catalogue record
Specifications
| Parameter | Documented value |
|---|---|
| Measurement | Inductive absolute singleturn, without integral bearing |
| Position and accuracy | 524,288 binary values per turn (19 bits), ±65 arcseconds system accuracy |
| Supply | 3.6–14 V DC at encoder. Typical 95 mA at 5 V without load. |
| Maximum power | 650 mW at 3.6 V and 700 mW at 14 V |
| Serial timing | Calculation time ≤5 µs, encoder clock limit ≤16 MHz, cable and receiver may lower the usable clock |
| Mechanical speed and axial motion | ≤15,000 rpm encoder limit. Permissible axial motion ±0.5 mm per the 1000353 specification. |
| Mechanical interface | 0YA flange, 44C Ø12.7 mm blind bore. IP20, −40 to +115 °C operating temperature. |
Use the tighter limit of the encoder, motor and drive. Functional safety depends on the complete installed system, safety-rated evaluation and the documented mechanical assembly. Electrical specifications (PDF) · Mechanical specifications (PDF)
Mounting and fit
The motor bearings locate the rotor. Seat the rotor’s blind bore on the prepared motor shaft shoulder, and seat the 0YA stator flange on the motor register and flange face. The central screw retains the rotor. Three axial screws secure the stator. Check both contact faces for burrs, debris, witness marks and fretting before reassembly. Bearing float can move the rotor relative to the stator even if the connector is sound.
The 1000353 drawing specifies a DIN 6912 M5×30–08.8–MKL central screw at 5 N·m, +0.5 N·m, and ISO 4762 M4×10–8.8–MKL flange screws at 2 ±0.1 N·m for the illustrated 0YA assembly. Confirm the fasteners, locking features, mating dimensions and final OEM procedure on your motor. The drawing has a separate access plug. Keep its specification distinct from the rotor screw. Mating dimensions and fasteners (PDF) · ECI 1319 EnDat22 operating instructions (PDF)
Use the mounting interface after a bearing or encoder replacement. Serial position can be readable even when the mounting clearance is near a limit. HEIDENHAIN’s mounting table lists a mounting interface for 810661-xx and a separate ExI wizard for certain other IDs. Verify a full revolution under the OEM-approved diagnostic procedure. Mounting diagnostics and supported IDs (PDF)
Interface and measuring method
The inductive sensor encodes the shaft position within one revolution. The receiver drives the differential CLOCK pair. It uses the bidirectional DATA pair for commands and replies, including position and protocol integrity checks. This exact EnDat22 type has serial position and status, with no A/B analog position pair. A singleturn position wraps once per mechanical revolution. The drive or machine must track travel across turns if the application requires it.
The optional external temperature sensor uses its own contacts at the encoder, separate from the serial pairs. The receiver and installed harness determine which temperature information is available. A valid serial reply, good mounting clearance and good motor commutation are separate checks.
Verified wiring
The table follows the EnDat22 ECI/EQI drawing in 1000353. Use the manufacturer connector view and housing key to locate the a/b rows. The M23 column applies to the documented HEIDENHAIN 9-pin SpeedTEC connection, after matching the harness at both ends.
| Function | PCB | 9-pin M23 |
|---|---|---|
| Uₚ / 0 V | 1b / 4b | 3 / 4 |
| Supply sense / return sense | 6a / 3a | 7 / 8 |
| DATA / complement | 6b / 1a | 5 / 6 |
| CLOCK / complement | 2b / 5a | 1 / 2 |
| External sensor T+ / T− | 8a / 8b in 4-pin section | Separate routing. No allocation in this feedback table. |
Keep unused contacts vacant and use the specified housing shield bond. Obtain the OEM drawing for other motor connectors and drive ends. HEIDENHAIN specifies completely assembled qualified cables for safety-related use. EnDat22 ECI/EQI pin drawing (PDF)
Cables inside the motor and at the machine
| ID | Endpoints and role |
|---|---|
| 1120948-xx | In-motor 16-pin PCB to 9-pin M23 SpeedTEC angled flange socket. Confirm length and external sensor routing for the exact motor. |
| 745796-xx | External lead from 9-pin M23 female to 8-pin M12 male coupling. |
| 524599-xx | External 8-pin M12 female to 15-pin D-sub male adapter. Verify tester or receiver compatibility. |
The listed internal lead is for the HEIDENHAIN connection in the drawing. For a different OEM harness, read its label and confirm both endpoint maps, strain relief and shield before ordering. Use the approved assembled lead on a safety axis. Cables and adapters (PDF)
Fault checks
Before opening the motor. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
- Inspect. Check the locking PCB plug, motor bulkhead, pin retention, oil or debris, crushed conductors and cable support. Look for loose rotor retention, uneven flange contact and signs of bearing movement before adjusting anything.
- Continuity and shorts. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics.
- Power under load. With an approved breakout fitted while off, a qualified technician can measure DC supply from PCB 1b to 4b on the documented unit. Compare the drive’s specified voltage at its output and at the encoder. A drop across a loaded harness can reveal a connection defect that an unloaded meter misses.
- Separate the symptoms. A missing serial reply points first to supply, protocol selection or clock/data wiring. Intermittency after shaft or bearing work calls for mechanical inspection and mounting diagnostics. Stable position with a torque or safety alarm calls for checking the drive configuration, safety commissioning and motor angle.
Motor and drive applications
The 0YA/44C assembly is an internal motor feedback option. An exact OEM motor using 810661-02 was not verified for this guide. Beckhoff’s AX5000 hardware reference distinguishes pure-digital EnDat 2.2 on its AX572x option from analog-assisted EnDat configurations. Its ECI 1319 table also lists an analog-assisted version. Match the exact drive hardware and the encoder label before applying that example. Beckhoff AX5000 EnDat feedback configurations
Angle of alignment and commissioning
The 0YA mounting clearance locates the sensor relative to the rotor. The motor’s commutation angle relates the reported position to the motor phase reference. Record the incoming drive settings and OEM-approved offset or memory before removal, if the equipment supports reading it. Restore only approved motor-specific data to a compatible replacement, then read it back and verify direction, physical alignment and drive commissioning. The encoder ID by itself supplies no fixed motor angle.
Drawings, pin maps and manuals
- HEIDENHAIN 1000353, EnDat22 product information (PDF). Pages 2–4 for fit and specifications, 6 for the leads and 7 for ECI/EQI wiring.
- HEIDENHAIN 1388764 operating instructions (PDF). 0YA / 44C EnDat22 functional-safety assembly. If a direct download redirects, request the number from HEIDENHAIN.
- HEIDENHAIN Encoders for Servo Drives, 208922 (PDF). See 810661-xx and the mounting-interface compatibility table.
- 810661-02 exact catalogue record. Catalogue downloads include the exact pin-layout number D533166.