Order an on-site visit or bench evaluation of Heidenhain ERN1387?
Request an on-site diagnosis when the fault occurs only in the machine or the encoder, wiring and drive need to be checked together. Include the encoder ID, motor order code, drive model, fault code and when the fault occurs.
Request bench evaluation if the encoder or motor is already out. Describe any work already done and have label and connector photos ready for follow-up. Ask for packing and shipping instructions before dispatching it. Keep the coupling and spacers identified with the original assembly.
Send an ERN 1387 service enquiry
Testing of Heidenhain ERN 1387 at your Site. What can be tested with Mitchell equipment ?
TI-5000JX · Encoder bench test
Mitchell documents the ERN 1387 under Generic Incremental with the TI-5101 1 Vpp adapter. Use the TI-5090 on the matching direct encoder connector or the TI-5010 on the documented Siemens motor feedback connection. Verify the exact cable and motor connector before testing. Mitchell calls for TI-5101 DIP switch 1 closed to select the C/D channels in the software. Mitchell’s ERN 1387 procedure
| Test | What to look for |
|---|---|
| A/B motion and R index | In Normal Commutation, check that the count changes consistently with direction, totals 8,192 quadrature counts per mechanical revolution from 2,048 signal cycles, and detects the R reference mark (called Z in Mitchell’s software). |
| C/D commutation track | In Sin/Cos Commutation, check the differential levels and angle progression at the test angles in Mitchell’s guide. C and D each complete one cycle per mechanical turn and are about 90° apart. |
| Analog signal quality | Use Mitchell’s 1 Vpp line-level method and the specified termination to check A/B differential amplitude. The generic square-wave line-level check is intended for TTL/HTL. For intermittent dropouts, a properly terminated differential scope measurement can capture what a steady meter reading misses. |
| Alignment on a motor | Compare the index-based angle in Normal Commutation with the exact motor’s alignment reference using the OEM procedure. A loose encoder on the bench can verify its outputs. Motor alignment requires the assembled motor and its reference. See the Siemens bench targets and OEM check. |
TI-3000JX · Can it run the motor?
Yes, for compatible motor assemblies. Mitchell documents a run test for some Siemens 1FT6, 1FK6, 1FT7 and 1FK7 motors fitted with this type of incremental feedback. The documented setup uses Generic Incremental, the TI-5010 feedback cable and the TI-5101 adapter with both DIP switches open so it passes A/B/Z. Confirm the full motor order code, feedback and power cables, and compatible servo amplifier before applying that setup. Mitchell’s Siemens run-test setup
Verify the encoder signals and motor alignment on the TI-5000JX first. The TI-3000JX run test then checks rotation, direction and speed stability of the assembled motor on a guarded, secured bench. A smooth bench run leaves OEM-drive compatibility and intermittent feedback faults to be checked separately. Mitchell’s run-test limits and test sequence
Knowledge BASE for ERN1387 Encoder; Data, Specifications, Dimensions, Mounting, Dismantling procedure, Manuals etc.
Shop-floor reference · Incremental rotary encoder
The ERN 1387 gives the drive two kinds of feedback. Its A/B tracks report motion, while its once-per-revolution C/D tracks help the drive establish rotor position for commutation. If a drive reports a feedback fault, check the full encoder ID and the cable before ordering a replacement.
Find the ID on your label
Record the full HEIDENHAIN ID, including the suffix, and the full motor and drive model codes. The mounting and supplied hardware can differ by ID.
| HEIDENHAIN ID | Stator mounting | Supplied hardware | Listed output |
|---|---|---|---|
| 749144-01 | Type 06 expanding ring, Ø65 mm motor-side mating bore | Mounting kit with M5×50 and M5×47 screws | ≈1 Vpp |
| 749144-05 | Type 06 expanding ring, Ø65 mm motor-side mating bore | Encoder exchange kit | ≈1 Vpp |
| 749146-xx | Plane-surface stator coupling for elevator servo drives | Confirm the supplied hardware for your full ID | ≈1 Vpp |
| 749147-02 | Supplied without a coupling | Spacer plates and central screw | ≈1.05 Vpp |
Shared by 749144-01, 749144-05 and 749147-02. 2,048 lines per revolution, an additional one-cycle sine/cosine track, nominal 5 V DC supply (±5%), IP40, a listed operating range of −40 to +120 °C, and a locking straight two-row 14-pin plug with configuration D319274. HEIDENHAIN lists a 210 kHz (−3 dB) cutoff on both 749144 records. Check the exact record for any other ID.
Find an ID quickly. Search the full ID in the table. If your label begins with 749146, search 749146 to find the family entry. The xx stands for the suffix on your label.
Before buying a substitute. Compare the taper, stator attachment, connector and pin assignment, included hardware, and the motor maker’s approved feedback and alignment requirements. The shared electrical layout alone cannot establish interchangeability. If your ID is absent, look it up on HEIDENHAIN’s site or send a clear label photo with the motor nameplate.
Current production and end-of-life status
Confirm by full HEIDENHAIN ID. As of 7 November 2026, public manufacturer sources confirm documentation for several ERN 1387 IDs, including an April 2025 product sheet for 749144-58. Current production and end-of-life status are unconfirmed. Ask HEIDENHAIN or the motor maker whether your full ID is available as new production, a service spare or an approved successor. HEIDENHAIN product information 1460370 (PDF) · HEIDENHAIN support
ERN 1387 specifications
These specifications apply to ID 749146-xx, the ERN 1387 with a plane-surface stator coupling for elevator servo drives. For other IDs, use the matching product record and motor documentation.
HEIDENHAIN product information 1085677, page 3 (PDF) · 749146-xx mounting drawing, page 2 (PDF)
| Parameter | Manufacturer specification |
|---|---|
| Incremental output | Approx. 1 Vpp analog sine/cosine (A and B) |
| Line count and system accuracy | 2,048 lines per revolution. System accuracy ±20 arcseconds. |
| Commutation track (Z1) | One sine cycle and one cosine cycle per revolution (C and D) |
| Reference mark (R) | One per revolution |
| Cutoff frequency (−3 dB) | ≥210 kHz |
| Encoder connection | 14-pin PCB connector. See the pin assignments. |
| DC supply | 5 V ±0.25 V (4.75–5.25 V) |
| Current draw | ≤130 mA without load |
| Stator coupling | Plane-surface coupling |
| Shaft geometry | Ø9.25 mm tapered shaft, 1:10 taper |
| Mechanical speed limit | 2,000 rpm maximum |
| Shaft starting torque | ≤0.01 N·m at 20 °C |
| Rotor inertia | 2.6 × 10−6 kg·m² |
| Axial allowance of measured shaft | ±1.5 mm for mounting tolerance and thermal expansion only |
| Radial runout of measured shaft | 0.13 mm |
| Vibration (55–2,000 Hz) | ≤300 m/s² through +100 °C. ≤150 m/s² above +100 °C through +120 °C. EN 60068-2-6. |
| Shock (6 ms) | ≤2,000 m/s². EN 60068-2-27. |
| Operating temperature | −40 to +120 °C |
| Ingress protection | IP40 when mounted (EN 60529) |
| Mass | Approx. 0.25 kg |
How Heidenhain ERN 1387 mounts - installation | Dimension Details
IDs 749144-01, 749144-05 and 749147-02 use HEIDENHAIN’s 65B shaft with a 1:10 taper and 9.25 mm functional diameter. That dimension describes the taper geometry. Use the mating drawing for the actual seat dimensions and tolerances. The product records also list M10 and M6 back-off threads. On the 749144 variants, the shaft locates on the motor’s tapered seat and the expanding ring restrains the encoder body in the motor-side bore. For 749147-02, confirm the motor’s coupling arrangement before ordering or dismantling.
The linked 65B/06 drawing calls out a Ø65 mm mating bore with +0.10/0 mm tolerance. That is a bore dimension on the documented configuration. Match the drawing revision to the supplied unit before using it for fit, extraction or screw selection.
749147-02 mounting sheet for ERN 1387.035 (PDF). If the link shows HEIDENHAIN’s download maintenance notice, use document number 1073758-91 when requesting a copy.
Before removal, record the cable routing, spacer stack and existing installation with photographs. Use the applicable motor and encoder instructions to select the extraction method, hardware and tightening sequence. If the old unit has already moved on its taper, its witness marks cannot establish the correct commutation angle. Use the motor maker’s commissioning procedure after replacement or any suspected movement.
HEIDENHAIN 65B/06 drawing and mounting instructions (PDF) · 749147-02 record with its own mounting-document listing
Interface · How the ERN 1387 sends feedback to the drive
Measuring method: incremental. Interface: analog sinusoidal incremental voltage signals, nominally 1 Vpp. The drive powers the encoder and reads the changing voltages as the shaft turns.
- A/B track. The versions documented here produce 2,048 sine/cosine cycles per mechanical turn. A and B are a quarter-cycle apart. The drive uses their order for direction, their frequency for speed and their relative voltages to estimate position within each cycle. That last step is interpolation. The receiver determines the effective measuring step.
- R reference mark. A once-per-turn reference lets the drive identify a repeatable shaft position as it passes the mark.
- C/D commutation track (Z1). One sine cycle and one cosine cycle per shaft revolution give a compatible drive the coarse rotor angle it uses for commutation, including at standstill. Machine position is established by the machine’s referencing procedure.
On a test bench. Vpp is the peak-to-peak signal swing. HEIDENHAIN characterizes A and B across each differential pair at a 120 Ω termination, with the specified supply at the encoder. Compare a differential scope reading with the exact ID’s data and the approved test setup. A DC supply reading tells you about the power feed. Evaluating signal quality requires observing the waveforms.
HEIDENHAIN encoder interfaces, 1 Vpp signals and interpolation (PDF) · ERN 1387 connector pin assignments
Wiring, Pin Out and signal checks for Heidenhain ERN 1387
Use it for Signal checking, manufacturing Cable, ordering Cables
Match the connector before probing. The PCB column uses the manufacturer’s lettered positions for the 14-pin encoder connector. Identify row letters, latch and viewing side from the connector illustration on PDF page 5. The M23 column describes HEIDENHAIN’s documented 17-pin cable/flange arrangement. Use your motor maker’s connector drawing at the motor and drive ends, where the assignment can differ.
| Function | 14-pin encoder PCB | HEIDENHAIN 17-pin M23 |
|---|---|---|
| Supply UP / 0 V | 1b / 5b | 7 / 10 |
| Sense UP / sense 0 V | 7a / 3a | 1 / 4 |
| A+ / A− | 6b / 2a | 15 / 16 |
| B+ / B− | 3b / 5a | 12 / 13 |
| Reference R+ / R− | 4b / 4a | 3 / 2 |
| Commutation C+ / C− | 7b / 1a | 14 / 17 |
| Commutation D+ / D− | 2b / 6a | 9 / 8 |
| Internal shield | — | 11 |
| Temperature T+ / T−, where fitted in the documented internal motor cable | — | 5 / 6 |
HEIDENHAIN shows each sense lead tied internally to its corresponding supply rail. Disconnect the encoder for cable-only continuity testing so those internal links are excluded. Cable shield bonding follows the applicable assembly drawing. Keep spare contacts vacant and identify wires by connector position and drawing.
What the signals tell you. A/B provide 2,048 cycles per mechanical revolution. R is the reference-mark channel. C/D give one sine/cosine cycle per mechanical revolution and carry the commutation position information. A usable A/B trace can coexist with a C/D fault or incorrect commutation alignment. For qualified waveform testing, use the approved fixture, receiver termination and a differential measurement across each +/− pair. A handheld meter reading on one leg cannot validate amplitude, quadrature or alignment.
HEIDENHAIN electrical reference (PDF, p. 5)
Standard ERN 1387 cables inside the motor
HEIDENHAIN lists these AGK output leads for the ERN 1387 with a 14-pin FCI PCB connection. Match the motor flange, pin map, cable length and temperature-sensor wiring to your motor’s drawing before ordering.
| HEIDENHAIN cable ID | Length | Ends and use |
|---|---|---|
| 332199-01 | 0.3 m | 14-pin PCB plug to 17-pin M23 right-angle flange socket with male contacts. Includes two temperature-sensor wires. |
| 332200-01 | 0.3 m | 14-pin PCB plug to an unstripped cable end for the motor maker’s termination. |
| 332200-04 | 1 m | 14-pin PCB plug to an unstripped cable end for the motor maker’s termination. |
HEIDENHAIN Cables and Connectors 1206103 (PDF). Search for 332199-01 in the cable list.
Heidenhain ERN 1387 Troubleshooting DoitYourself : What you can check on the machine
Record the exact drive alarm, when it occurs and any recent work on the encoder, motor, cable or drive. Start with the connector and cable. A fault that changes when the machine moves may be in the cable or its termination.
Before touching the assembly. Authorized technicians should follow the machine and site lockout procedure. Isolate all energy sources, secure loads against motion, handle stored energy including drive capacitors, and verify isolation and de-energization before disconnecting anything. Elevator and suspended-load work requires the applicable site and OEM procedures. Hazardous-energy control reference
Connector condition and seating
- With power isolated, inspect both mating faces in good light. Look for bent or recessed pins, cracked inserts, corrosion, moisture and debris. A metal chip or stray shield strand can bridge adjacent contacts. Use the connector maker’s approved cleaning method. Replace damaged contacts or housings before mating them.
- Check the cable for crushed sections, abrasion or a loose backshell or strain relief. Align the key, seat the feedback plug squarely on the motor socket, then engage the latch or coupling collar as specified by the motor maker. A tight collar alone does not prove the plug is seated. Confirm the motor socket is secure and the cable’s weight is supported by the strain relief.
Electrical check with power off · Cable continuity and shorts
- Disconnect the passive feedback cable at both ends and separate it from any inline electronics or sensors. Use the drawing for that exact harness. Set a multimeter to resistance or continuity, touch the probes together to establish lead resistance, and use adapters that fit the contacts.
- Check each intended path end to end. A good path has low, stable resistance consistent with the cable length and specification. An open indication (usually OL) or a reading that jumps when you gently flex the isolated cable suggests a broken conductor or contact problem.
- Check for shorts between adjacent pins and other conductors that the drawing shows as isolated. Check UP to 0 V and each signal lead to 0 V. Also check each signal lead to the shield and to the metal shell where accessible. An isolated pair normally reads open. A stable low resistance on a pair that should be isolated points to a bridge in the cable or plug. A documented shield-to-shell bond can read low by design. 0 V is the encoder supply return. The shield and shell serve a separate purpose.
Keep resistance and insulation testers off connected feedback electronics. The encoder ties its sense leads to the corresponding supply rails internally. The isolated-cable check avoids mistaking those internal paths for a cable short. A cable can pass these checks and still have noise or signal-quality problems. Fluke continuity guide
Mechanical check · Center screw and stator coupling
- Center screw. With the motor isolated and secured, inspect the fastener and spacer stack where the OEM procedure allows access. Look for a backed-out screw, shifted witness marks or evidence the shaft has moved on the taper. The center screw retains the encoder rotor on the motor shaft. Tightening by feel cannot establish that the taper is seated or that the encoder is still aligned.
- Stator coupling. The encoder body should be held rigidly against rotation relative to the motor housing. On 749144-01 and 749144-05, check that the Type 06 expanding ring is seated in its mating bore and that there is no visible shift or looseness. For 749147-02, inspect the actual OEM stator attachment. HEIDENHAIN supplies that ID without a coupling.
If the shaft or body has shifted, record what moved and keep the motor out of service until the fit, fasteners and commutation alignment have been verified against the applicable OEM instructions. Mounting drawings by ID
Electrical check with feedback powered · 5 V supply under load
This check is for a qualified technician with protected low-voltage test points or an OEM-approved breakout harness. Fit the breakout while isolated and keep the encoder connected so the reading is under load. Use the approved test state that powers feedback while preventing motor motion and keeping loads secured. Leave exposed live cabinet parts and closely spaced plug contacts to specialist testing. Electrical work practices
- Set the meter to DC volts. Put the black lead in COM and the red lead in the V/Ω socket. A current jack can short the supply during a voltage measurement.
- Measure at the encoder end with black on 0 V and red on UP. Through the breakout for the documented 14-pin layout, use black on 5b, red on 1b. For HEIDENHAIN’s documented 17-pin M23 arrangement, use black on 10, red on 7. Use the exact motor drawing for any OEM external connector and confirm its viewing side. Use the supply return as the meter reference.
- Expect 4.75–5.25 V DC at the encoder for the three IDs above. If the reading is low at the encoder, compare with the drive’s documented supply test point under the same conditions. A healthy source with a low reading at the encoder points toward a voltage drop in the supply or return path, including a poor contact. A low reading at both ends calls for checking the drive supply, protection state and connected load. If the reading is high, stop and verify the supply setting and pin assignment. A good steady reading confirms the supply only at the time of the test.
- Return the equipment to its isolated state before removing the breakout or disturbing a plug.
Fluke DC voltage guide · HEIDENHAIN connector reference (PDF)
| What you observe | What to check next |
|---|---|
| Fault changes with cable position | Inspect strain relief and contacts, then flex-test the disconnected cable. If the symptom stays with a known-good cable, inspect the motor-side connector and internal pigtail. |
| Dropout mainly during motion or high load | Check feedback-cable routing, documented shield bonds, connector condition and supply under load. Ask a technician to capture waveforms during the fault under an approved test setup. |
| Fault began after replacement or mechanical work | Compare the complete IDs, taper seating, coupling and spacer stack, and connector map. Verify C/D and OEM commutation alignment before returning the axis to service. |
| No position feedback with a known-good cable | A controlled bench test can separate an encoder fault from machine wiring or a drive input problem. If the encoder passes on the bench, check the machine-side supply, receiver and drive configuration. |
If these checks pass and the fault remains, a differential waveform or bench test can check signal quality and commutation. Capture the original alignment before disturbing the assembly when the OEM procedure calls for it. See the specialist test options
Where Heidenhain ERN 1387 is USED on Servo Motor applications
- Siemens. Mitchell documents ERN 1387-style sine/cosine commutation feedback on some 1FT6, 1FK6, 1FT7 and 1FK7 motors. Read the complete motor order code and feedback option before using an external connector drawing. Mitchell’s Siemens motor guide
- Moog. Mitchell identifies ERN 1387 as one possible HEIDENHAIN incremental option alongside ERN 1185. Match the actual label and motor code. Mitchell’s Moog motor guide
- HEIDENHAIN QSY and elevator servo applications. Manufacturer literature lists QSY 96, 130 and 260 cable applications with ERN 1387 and documents its use in elevator servo-drive control. Match the assembly and drawing to the actual motor. QSY motor brochure (PDF)
Encoder angle adjustment · Siemens servo motors
Commutation alignment ties the encoder’s position reference to the motor rotor’s electrical phase. Use the complete motor order code, encoder version and OEM instructions to select the reference. Mitchell documents this feedback on some Siemens 1FT6, 1FK6, 1FT7 and 1FK7 builds.
| Documented static rotor lockup | Electrical angle on tester |
|---|---|
| +U / −V | 150° electrical |
| +U / −W | 210° electrical |
These are tester readings at two specific rotor lockups on the documented Siemens setup. Confirm phase identification, feedback direction and the motor pole count. Use Normal Commutation for the bench alignment reference and Sin/Cos Commutation to inspect C/D signals. Mitchell’s Siemens ERN 1387 procedure · TI-5000JX training manual
Siemens OEM verification. In §4.6.1, Siemens specifies a dynamic check for the listed 1FT6, 1FK6 and 1FK7 configurations with ERN 1387.001, .003 or .020. The encoder reference mark coincides with the rising zero crossing of the phase-U back EMF measured to neutral in Siemens’ setup. Use the motor-specific procedure for other builds, including 1PH, Moog and elevator motors. Siemens assembly and adjustment instructions 610.41 304.02 (PDF, printed p. 20)
Qualified bench work. Secure the motor and load, isolate the machine drive and follow the approved fixture and commissioning procedure. A back-driven permanent-magnet motor generates voltage. Verify alignment on the assembled motor before returning the axis to service.
Drawings and manuals relevant to Heidenhain ERN 1387
- ERN 1387 product information (PDF) — application-specific specifications and drawings on pp. 2–3, connector views and pin table on p. 5.
- 65B/06 mounting instructions (PDF) — check the configuration codes on the cover before use.
- HEIDENHAIN 06/65B operating instructions (PDF) — applicability and instructions for the encoder.
- Mitchell TI-5000JX Training Manual — specialist feedback testing reference.