What specialist testing can show
TI-5000JX bench. Mitchell lists AC58 parallel wiring and its TI-5000JX generic parallel mode reads up to ten inputs simultaneously. Verify voltage and breakout for this item.
TI-3000JX motor run. Machine or motor run compatibility depends on the application. The documented scope here is parallel feedback diagnosis.
Starting lead. Use the verified 17-contact AC58 parallel breakout and a compatible input fixture.
Hengstler AC58 0010 / PG 10-Bit Parallel Gray Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| AC58/0010ES.41PGU · 0565363 | Hengstler’s exact worked example. 0010 means ten bits, PG means parallel Gray, and U identifies the documented axial plug option. |
| PB code | Parallel binary option in the AC58 order table. Match the PLC input mode to the actual output code. |
| AC58 SSI or BiSS | Other AC58 families use a serial connection. Read the complete match code before choosing a wiring diagram. |
Production and end-of-life status
Hengstler provides a product record for this exact match code. Confirm current orderability and any revision through that record.
Specifications
| Parameter | Verified scope |
|---|---|
| Position | 10-bit singleturn, or 1,024 possible positions per revolution, on code 0010. |
| Power | Code E specifies 10–30 V DC for the documented parallel variant. Verify the input fixture ratings before applying power. |
| Fit | S.41 designates a synchro flange and 6 mm solid shaft in the ordering table. |
| Connector | U identifies the 17-contact axial Conin M23 branch with the specified direction convention. |
Interface and measuring method
Ten output lines present one Gray word for absolute position. Only one bit changes between adjacent valid Gray positions. The receiver converts that word to a number, so selecting binary interpretation can make otherwise healthy position data look erratic.
Mounting and fit
Use the S.41 synchro-flange outline to confirm shaft diameter, flange seat and axial clearance. Check the coupler and mounting surface for movement before interpreting repeatability.
Wiring and connector scope
Use the exact 10-bit singleturn M23 diagram from the parallel data sheet. Identify the supply and return, individual bit lines and any option circuits before connecting a PLC or tester. Match output levels to the approved input fixture.
Internal motor and machine cables
Keep a conductor-to-bit map for the fitted cable. Inspect each isolated conductor end to end and verify the shield arrangement using the M23 connector drawing. Obtain the cable by plug and machine input type.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Position jumps at regular points | Check for a stuck or crossed bit and confirm Gray interpretation in the controller. |
| All outputs appear dead | Verify supply and common at the approved breakout, then inspect the plug and full harness. |
| Position counts backwards | Confirm the U connector and direction convention, machine decoding and shaft orientation. |
Angle of alignment and commissioning
Record the original machine zero, direction convention and coupling position before removal. Verify the full Gray code progression and machine reference after fitting.
Motor and drive applications
Industrial AC58 parallel-output variant
Confirm the actual code, full plug drawing, input ratings and machine cable by the nameplate.
Drawings, pin maps and manuals
- Hengstler Encoders. Absolute Encoders, AC58 Parallel Wiring
- Hengstler AC58 Parallel technical datasheet. Ordering code, electrical connections and mounting drawings for the parallel variants.
- Hengstler AC58/0010ES.41PGU. Exact 10-bit worked example.
- Mitchell Generic Parallel Absolute Encoders. Ten-input bench scope and Gray decoding.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation