Site visit or send-in evaluation
We can compare the HE-02 serial position and quadrature path, then check the robot's motor harness and reference history. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Mitchell documents HE-02 serial and separate quadrature tests on TI-5000JX. Its TI-3000JX guide also documents HE-02 run selections by motor pole count. Match the actual motor phases and pole count, 17-pin fixture and selection before any controlled run.
Kawasaki HE-02 Sanyo Denki E03007758 Robot Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is E03007758. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| E03007758 / HE-02 | Mitchell cross-references the Sanyo Denki and Kawasaki designations. Confirm the full encoder label and motor nameplate. | Serial section plus quadrature pulse section. 8,192 counts per turn in the documented setup. |
| H20/M21 | Other Kawasaki feedback used on different motors and harnesses. | Mitchell assigns separate direct and motor cables. Match the complete label even where counts per turn agree. |
Production and end-of-life status
Mitchell documents the installed family. Confirm Kawasaki or Sanyo Denki replacement availability from the actual robot axis and motor serial.
Specifications
| Parameter | Value and scope |
|---|---|
| Feedback | Kawasaki serial and quadrature per Mitchell HE-02 reference |
| Counts per mechanical turn | 8,192 for HE-02 / E03007758 in Mitchell's documented test setup |
| Documented motor-side lead | TI-5026 for the 17-pin circular MS variant |
| Other test lead | TI-5023 is listed with conflicting D-sub sizes in the support article and cable index. Confirm the current cable sheet. |
| Motor pole options in run guide | Mitchell lists separate P4, P6 and P8 HE-02 profiles. Verify the specific motor. |
The table identifies the assembly each value applies to.
Mounting and fit
Before removing the encoder, record the full robot, axis and servo motor order, the as-found orientation and any reference marks. With the axis secured and isolated, inspect the coupling, rotor retention and encoder housing mounting. Get the motor assembly drawing for fit dimensions and fastening. Preserve the robot reference data through the approved service procedure.
Interface and measuring method
The HE-02 supplies a serial position path and a separate quadrature path. A bench test can compare them over the same shaft movement. A good serial read can coexist with a damaged pulse path or harness conductor. If the readings agree on the bench, compare motor-side and controller-side signals and check the axis reference.
Verified wiring
Obtain the exact motor-side drawing and TI-5026 connector sheet before powering the device. Use the plug view and cavity numbers on the actual connector. Separate the serial pair, incremental conductors, supply and shield in the harness checks. Confirm the supply at the approved reference points for the fitted HE-02 build.
Cables inside the motor and at the machine
TI-5026 is documented for the 17-pin circular MS connection. Mitchell also lists TI-5023, but its support and index descriptions differ on the D-sub size. Use the latest drawing and actual plug to resolve that conflict. Identify the installed internal lead and the robot axis cable by the full motor and robot serial.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Serial works, count or speed feedback drops | Compare the quadrature pair at both ends with the correct receiver and check the disconnected harness. |
| Both paths disappear when the axis flexes | Check supply, plug latch, shell connection and strain points in the cable. |
| Incorrect axis reference after replacing feedback | Verify mechanical retention and the OEM reference or mastering procedure before production movement. |
| Position runs in the wrong direction or shows the wrong count | Confirm the precise encoder selection and drive or tester configuration. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Mitchell identifies HE-02 on applicable Kawasaki robot motors and cross-references the Sanyo Denki E03007758. The exact axis and motor suffix must be verified from their labels. The H20/M21 protocol and cable leads are listed separately.
Angle of alignment and commissioning
Keep the robot's axis reference, rotor commutation and mechanical coupling relationship separate. Record the original assembly and controller state before encoder removal. After any approved replacement, verify the OEM commissioning and reference procedure for that robot, axis and motor.
Drawings, pin maps and manuals
- Mitchell Kawasaki serial encoder guide. HE-02 identity, count and serial versus pulse checks.
- Mitchell Kawasaki run guide. HE-02 motor run options by pole count.
- Mitchell manufacturer cable index. TI-5026 17-pin MS and TI-5023 catalogue entry.
These references describe the application and test route. The OEM encoder datasheet is still needed.