Encoder and resolver technical library
KEBA / LTi LST-220-4 Resolver 1R / 3R Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment
KEBA / LTi LST-220-4 with Resolver 1R / 3R is covered in this technical guide. Use it to identify the fitted assembly, compare the documented feedback branches, preserve incoming alignment and readable data, and prepare a scoped UAE site visit or send-in evaluation for installation, repair and alignment.
Identification · Testing · Specifications · Mechanical fit · Wiring · Alignment · Documents · Service enquiry
Identify the fitted motor and feedback
| Identification item | Scoped information |
|---|---|
| Manufacturer / grouped base | KEBA / LTi LST-220-4 |
| Reference | TCG1681; SpareFaber service-guide reference, not an OEM part number |
| Frame / family | 220 |
| Catalogue M0 / stall reference | 115 Nm; match the selected catalogue row, conditions and complete fitted order |
| Cooling / assembly | Catalogue LST build; identify any fitted external fan, brake and thermal option |
| Motor-data source | KEBA LSN/LST motor table p.104; resolver compatibility p.14 and LST order code pp.66–67 |
| Mechanical source | p.105 |
| Coverage boundary | resolver branch; base identifier omits complete speed/winding/shaft/brake/factory suffixes |
Photograph the complete motor plate, serial, encoder label, feedback connector face and drive nameplate before disturbing the assembly. Record the actual brake, shaft, mounting, cooling, thermal sensor and speed/winding fields. 1R / 3R — separate 1-pole-pair and 3-pole-pair subcases is the documented branch grouping used here; it is not a full factory order or an authorization to exchange devices.
1R and 3R stay together in one motor-base resolver guide while their electrical cycle counts, scaling and actual device details remain distinct. Do not confuse resolver pole pairs with motor poles. Identify a fitted 1RY safety option separately; this guide does not validate a machine safety function.
Specialist feedback testing
Device-level test scope: Use TI-5000JX resolver hardware with the lead verified for the fitted KEBA 1R or 3R connector and device. Record actual resolver speed, excitation and sine/cosine pair polarity before interpreting the angle. A 3R resolver gives three electrical cycles per mechanical revolution, so a one-speed selection can give a misleading mechanical-angle display. TI-3011 may expose resolver signals for observation; it does not identify the correct motor-bulkhead lead or excitation by itself.
Record the tester hardware, lead/module, software version, selected feedback type and actual fitted label with the report. First record the incoming fitted-device configuration and relevant position/signal observations. Preserve supported readable identity and data before any write. A changing count or angle alone does not prove correct mechanical installation, signal quality, commutation sequence or drive configuration.
| Test record | What the observation establishes |
|---|---|
| Label and setup match | The selected device, electrical interface and supply/excitation match the identified branch |
| Slow manual movement | Direction, continuity, cyclic behaviour and the applicable index/turn transition can be compared |
| Excitation and secondaries | Record primary excitation, secondary pairs, angle and vector behaviour |
| Independent signal checks | Verify sine/cosine secondary polarity and behaviour through the actual cable |
| Before/after report | Incoming configuration and each approved service change remain traceable |
Motor-run scope: TI-5000JX feedback evaluation and TI-3000JX motor-run approval are separate decisions. Establish full motor parameters, pole count, phase convention, fixture/load, brake handling and speed/current limits before a run. A supported feedback protocol does not approve a run profile for this complete motor. No universal minimum firmware or exact motor-bulkhead adapter is asserted here.
Motor data and resolver reference
| Parameter | 1R branch | 3R branch |
|---|---|---|
| Resolver pole pairs | 1 | 3 |
| Resolver electrical cycles per mechanical turn | 1 | 3 |
| Scoped OEM compatibility | All LST | From LST-050 |
| Signal type | Analogue excited resolver | Analogue excited resolver |
| Angle scaling | Match the actual one-pole-pair setup | Do not apply one-pole-pair mechanical-angle scaling |
| Excitation / fitted device | Verify actual label and matching device specification | Verify actual label and matching device specification |
| Turn memory / serial identity | No retained absolute ST/MT claim | No retained absolute ST/MT claim |
| Separate options | 1RY safety variant needs its own identification | 5R is not listed as applicable to LST in the compatibility table |
The catalogue torque reference for this grouped base is 115 Nm. It is used for identification and priority, not as momentary peak torque or a guaranteed rating for every speed/winding/cooling condition. Keep catalogue stall M0, rated Mn and short-duration Mmax separate. The selected 115 Nm row retains its published winding, thermal, mounting and cooling conditions.
Resolver 1R/3R is analogue feedback rather than an ST/MT serial absolute encoder. The 3R cycle count describes resolver speed, not three retained machine turns.
1R and 3R stay together in one motor-base resolver guide while their electrical cycle counts, scaling and actual device details remain distinct. Do not confuse resolver pole pairs with motor poles. Identify a fitted 1RY safety option separately; this guide does not validate a machine safety function.
Mechanical fit, cooling and removal reference
Compare the 220-frame resolver/1R/3R length and drawing column on p.105. Brake, shaft, sealing, raised/angled connector and feedback-holder options can alter the fitted assembly. Do not borrow a G6.x, G7.x or G12.x encoder length merely because the motor base matches.
| Fit item | Record and compare |
|---|---|
| Flange / pilot / mounting holes | Use the exact drawing and mounting version, including connector clearance |
| Shaft / key / coupler | Record actual dimensions, insertion depth and machine reference before removal |
| Encoder mounting | Identify holder, coupling, fasteners and mechanical reference from the fitted device |
| Brake and fan | Identify options and added envelope; verify their separate electrical circuits |
| Seals / coolant / enclosure | Match the actual cooling arrangement and ingress-protection build |
Mark the incoming relationship between motor housing, feedback body, shaft and machine reference. Support the assembly without loading the encoder shaft or bearing through an improvised puller. Use the documented removal and assembly method for the fitted device; no unreviewed taper, fastening torque, air gap or insertion force is supplied by this grouped guide.
Mechanical drawings to compare: p.105. Connector orientation and holder variants can change practical clearance even where the nominal frame is the same. A similar-looking donor motor does not establish identical shaft, brake or encoder fit.
Wiring and connector scope
Use the actual 1R/3R resolver connection and fitted connector build. The selected 220-frame drawing has a resolver length column; it is not a G6.x, G7.x or G12.x encoder pinout. The p.14 compatibility table lists 1R for all LST and 3R from LST-050; it marks 5R not applicable to LST despite a flattened generic order list containing 5R text.
| Circuit / branch | Identification boundary |
|---|---|
| Excitation and secondaries | Trace the actual primary, sine and cosine pairs using the fitted resolver drawing |
| 1R versus 3R | Confirm resolver pole-pair count from the label/order before setting mechanical-angle scaling |
| Supply assumptions | Do not apply the G3/G5/G12.x +5 V optical or G6.x classic-HIPERFACE supply table |
| Motor / feedback contacts | Match connector keying, contact-side view, internal loom and screen |
| Other circuits | Keep brake, fan, thermal sensor, phases and protective earth separately identified |
Read connector drawings in their stated contact-side view and verify numbering, keyway, male/female contacts and shell position. Check continuity with both ends isolated before applying feedback power. Photograph and label any repaired or custom loom so the test report identifies the actual route used.
Keep motor phase conductors, brake supply, fan supply, protective earth, thermal circuits, encoder supply/return and signal pairs distinct. Do not infer a pinout from wire colour, a shared connector shell, another manufacturer's motor or an electrically different feedback option. If a diagram caption and an order table disagree, resolve the actual fitted branch before energizing it.
Test leads, internal loom and machine cable
| Connection layer | What must be established |
|---|---|
| Direct encoder plug | Exact device connector and compatible bench lead; not automatically a motor-bulkhead connection |
| Motor internal loom | Continuity, shielding, strain relief and any changes made during earlier repairs |
| Motor feedback / hybrid bulkhead | Correct socket, contact view, branch and separate power/brake/thermal circuits |
| Machine cable | Both endpoint pinouts, length/routing, drag-chain damage and shield termination |
| Drive / tester end | Correct installed selection, supply module and interface-specific lead |
A device that reads correctly with a direct plug but fails through the motor can point to the internal loom or bulkhead route. A device that works at the motor but fails through the machine harness requires an endpoint-by-endpoint cable check. Document which layer was bypassed; do not report a complete motor or machine harness as proven from a direct encoder test.
Keep excitation and both secondary pairs identified through each cable layer. Check winding continuity and polarity against the fitted drawing; do not apply a DC encoder-supply assumption to the resolver.
No complete machine-cable part number or universal lead is assigned to every configuration in this guide. Select or document the cable only after the complete motor/encoder labels and both connector endpoints are known.
Diagnostic symptoms and useful comparisons
| Reported symptom | Evidence to collect before changing parts |
|---|---|
| No angle / unstable angle | Fitted excitation, primary/secondary continuity, polarity, resolver speed and lead |
| Position changes but drive faults remain | Status codes, configuration, motor-data interpretation and phase/alignment relationship |
| Intermittent or noisy behaviour | Connector contact, strain/routing, shield integrity and signal quality through each cable layer |
| Incorrect direction or scaling | Recorded device direction, selected protocol/word format and drive scaling; do not rewrite offsets to hide it |
| Machine reference / scaling unexpected | Resolver speed, controller offset, direction and machine multi-revolution reference |
| Fault appeared after removal | Original reference marks, mechanical holder/shaft relationship, supported offsets and before/after reports |
Compare one identified path at a time: direct encoder, internal loom, motor bulkhead, then machine cable/drive. Retain the original symptom, fault codes and setup with each result. An isolated cable fault, an unsupported test selection and a damaged encoder can present a similar initial symptom.
A resolver angle is affected by excitation, winding polarity and resolver speed. Keep resolver speed independent of motor poles, and compare secondary/vector behaviour before changing a controller offset.
Alignment, offsets and memory preservation
Capture the incoming shaft/machine reference, device label, drive offsets, direction and the relevant angle/index/commutation relationship before removal. Preserve controller configuration and the homing/reference method with a report identifying the fitted device, fixture, lead and selected test setup.
After mechanical work, check the fitted encoder's mounting and signal quality before interpreting an angle. A wrong cable/selection or an unstable mechanical fit can make an otherwise valid offset appear incorrect. Do not copy an angle, memory image or motor profile from another motor merely because its frame or protocol matches.
The resolver/incremental interface does not establish serial encoder memory or a retained multiturn turn counter. Preserve available controller offsets, reference/homing data and mechanical alignment through the application-specific workflow. Do not apply an absolute-encoder memory image to this device.
If the original relationship or data is unavailable, define a motor-specific recovery method from documented motor/feedback information and the installed test system. This guide does not prescribe a universal lock-up angle, firmware threshold, phase convention or replacement memory file. Record the before/after evidence and the exact change performed.
Service scope, replacement and availability
This is a technical-guide/service listing for KEBA / LTi LST-220-4, not a claim that a complete motor, encoder, brake, fan or cable is held in stock. Parts and service scope follow review of the full fitted labels, connector photos, fault report and required operating conditions.
A replacement decision must compare interface, absolute/analogue behaviour, supply, mounting, shaft/holder, connector route, thermal/brake options, supported motor data and drive compatibility. A motor-base match alone does not establish a drop-in replacement. Catalogue inclusion does not prove current production, exact-order availability, turnaround or certification.
Provide clear label and connector photographs plus the reported symptom and any previous repair changes for a scoped UAE site visit or send-in evaluation. The service quotation can then identify the assessment, repair, alignment or installation work and any parts that require confirmation.
Applications and practical service enquiries
The selected 220 frame/family and 115 Nm catalogue reference place this guide in the identified motor range; they do not rate a new machine duty. Typical enquiries concern feedback faults, connector/loom repair, motor replacement identification, reinstallation after mechanical work and preservation of existing alignment/data.
- Compare the exact motor and feedback branch during a repair intake.
- Document a cable-versus-encoder investigation before replacing an otherwise serviceable assembly.
- Prepare an installation or reinstallation visit with complete labels, drive details and machine reference.
- Assess an identified replacement against the actual shaft, cooling, brake, connector and data requirements.
Use the documents below and the exact fitted-label evidence when comparing another interface or motor base.
Request installation, repair or alignment assessment and include reference TCG1681.
Drawings, manuals and evidence
- KEBA LSN/LST order catalogue 0814.25B.8-00, 11/2022 — readable reproduction of the OEM catalogue. KEBA LSN/LST motor table p.104; resolver compatibility p.14 and LST order code pp.66–67. Mechanical reference: p.105.
- Mitchell generic resolver testing. Verify resolver speed, excitation convention and the actual compatible lead.
- Resolver compatibility p.14; LST order fields pp.66–67; motor data p.104 and drawing p.105. Resolve the complete actual resolver connector/device before choosing a cable or excitation.
These references support the scoped family and documented options. The complete fitted order and actual device revision determine the final wiring, envelope, software selection and service method. Keep the source edition/page, nameplate photos and measured setup with the report so a later technician can reproduce the identification.
The cover is a branded service illustration with concise headings. It is not an OEM dimensional drawing or proof of the exact motor/encoder installed in a machine.
Frequently asked questions
Is this a complete factory motor order?
No. KEBA / LTi LST-220-4 is a guide grouping. Match all winding/speed, shaft, mounting, cooling, brake, feedback and custom-order fields on the actual plates.
Does this resolver retain a multiturn position?
The resolver supplies angle within its electrical cycle. Controller offsets and machine multi-revolution reference are separate application data.
Can I use another motor's cable or test selection?
Only after the actual device, supply, complete endpoint wiring and installed support are established. A shared shell, frame or protocol name is not enough.
Does feedback testing prove a motor-run setup?
No. Exact motor parameters, fixture/load, brake and phase/alignment conventions require their own motor-specific run-test approval.
Can the original alignment and data be preserved?
Capture available incoming identity, mechanical reference, supported angles/offsets and readable data before removal or writes. Recovery after missing data requires a defined motor-specific method.
How do I request service?
Send full motor and encoder labels, connector photographs, drive details, fault symptoms and previous repair changes with TCG1681. Installation, repair, alignment and site/send-in scope follow identification.
Enquire about this encoder or resolver
Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.