What specialist testing can show
TI-5000JX bench. Mitchell lists AKM EnDat support on TI-5000JX. Confirm the DA/DB frame, encoder ID, lead and software profile.
TI-3000JX motor run. Mitchell lists AKM EnDat among its TI-3000JX-supported options. Confirm exact motor poles, fixture and drive configuration.
Starting lead. Choose the fixture by AKM frame, connector and fitted HEIDENHAIN ID.
Kollmorgen AKM DA / DB EnDat 2.1 Servo Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| DA | Kollmorgen’s optical EnDat 2.1 singleturn option. The Mitchell-linked key lists ECN 1113 / ECN 1313 by motor frame. |
| DB | Optical EnDat 2.1 multiturn option. The Mitchell-linked key lists EQN 1125 / EQN 1325 by motor frame. |
| LA or CA | Other AKM codes identify different hardware. Use the full motor order and fitted encoder ID before applying the DA/DB drawings. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Interface | EnDat 2.1 for DA and DB in the OEM code table. |
| Within-turn and turn data | DA reports absolute angle within a turn. DB provides a turn field on the multiturn configuration. |
| Incremental output | The Mitchell-linked table identifies different analogue period counts across AKM frames. Read the fitted encoder and frame before setting the count. |
Interface and measuring method
The drive exchanges clock and data with the EnDat encoder. Where the fitted variant also carries analogue incremental signals, a technician can compare serial and incremental behavior separately. An apparently healthy angle reading is only one part of the feedback check.
Mounting and fit
Use the Kollmorgen mechanical drawing for the exact AKM frame. Record shaft engagement, coupling and encoder connector routing from the installed assembly. Match the HEIDENHAIN ID before ordering a mechanically compatible replacement.
Wiring and connector scope
The AKM connectivity manual identifies the connector by motor frame, drive and connection code. Trace the EnDat clock/data pairs and any analogue channels from the matching connector view.
Internal motor and machine cables
Use the complete AKM motor order and drive model to select the OEM feedback cable. Identify the internal encoder harness by the fitted connector and assembly drawing. Treat direct test cables and drive cables separately.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Within-turn angle reads and turns are wrong | Verify DA versus DB and the drive’s configured turn mode. |
| No serial reply | Check the fitted connector, isolated clock/data pairs and EnDat supply under the approved procedure. |
| Bench test passes and drive faults | Compare the complete machine cable, drive configuration and incoming alignment record. |
Angle of alignment and commissioning
Record the drive settings, incoming absolute reference and any relevant motor data. Confirm turn mode, direction and position after fitting. Use the OEM commissioning method for the fitted motor and drive.
Motor and drive applications
Kollmorgen AKM with DA or DB
Confirm actual motor order, encoder ID, analogue period count and matched test cable.
Related SpareFaber guides
Drawings, pin maps and manuals
- Kollmorgen AKM support. Supported feedback and linked AKM code table
- Kollmorgen AKM connectivity manual. Feedback-to-motor code matrix and cable diagrams by option and connector.
- Kollmorgen AKM feedback code reference. DA/DB singleturn and multiturn EnDat options.
- Mitchell-linked AKM feedback table. Model-dependent encoder types and ordering codes.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.