Site visit or send-in evaluation
Send the full 8.5863 order number, shaft and connector photos, SSI receiver model and your current clock, code, singleturn and multiturn settings. Note if the position jumps at a turn boundary or after a replacement. Use the enquiry form to share the details.
What specialist testing can show
A compatible SSI reader or controller can check position, direction and repeatability over several turns. A qualified technician can compare CLOCK and DATA with an appropriate differential scope and check that the receiver uses the same bit length and code. Compare behavior at a slower supported clock to help isolate a cable or termination problem. Exact Sendix 5863 support for Mitchell TI-5000JX and a TI-3000JX run profile were not verified. Kübler SSI timing and ratings (PDF) · Beckhoff SSI commissioning (PDF)
Kübler Sendix 5863 SSI Multiturn Encoder technical reference
Find your part number
Read the full Kübler order code. 8.5863 is the solid-shaft series. In 8.5863.112A.G323.0030, the illustrated code selects the IP65 clamping flange, Ø6 × 10 mm shaft, 10–30 V interface, axial special-length lead, SSI Gray format, 13 singleturn and 12 multiturn bits, and the SET button/status LED option. The final 0030 is a 3 m lead.
| ID or ordering field | What it selects | Practical implication |
|---|---|---|
| 8.5863.112A.G323.0030 | Manufacturer order example. Gray SSI, 13 ST + 12 MT, 10–30 V DC, 3 m lead. | Use the cable map for interface 2 and connection A. |
| 8.5863 · code B / G | SSI binary / SSI Gray in the code position | Select the corresponding format in the receiver. |
| 8.5863 · code C | BiSS binary in the same code position | Use the BiSS documentation for the full unit. |
| 8.5883 | Hollow-shaft companion series | Separate coupling and flange drawing. |
Read the interface and connector fields together. Some 5863s have extra SinCos or RS422 incremental signals and others have remote supply sense. Kübler order-code and length example (PDF)
Production and end-of-life status
Kübler lists Sendix 5863 and publishes a December 2025 data sheet. Ask for current orderability and an approved successor for the full code and any special length or approval. Reviewed 7 November 2026. Kübler 5863 product page
Specifications
| Parameter | Value / scope |
|---|---|
| Measurement | Optical absolute with mechanical multiturn gearing, battery-free turn counting |
| Word capacity | 13 singleturn bits (8192 positions) plus 12 multiturn bits (4096 turns) on the reference build |
| Supply | 10–30 V DC for interface code 2, maximum 50 mA without load per the data sheet |
| SSI clock | 50 kHz–2 MHz encoder range. Use a supported value for the receiver and cable. |
| Position timing | ≤1 µs data refresh for singleturn resolutions up to 14 bits. SSI monoflop time ≤15 µs in the datasheet. |
| Mechanical reference | Ø58 mm IP65 clamping flange, Ø6 h7 × 10 mm shaft with flat. The cited cable-version temperature is −30 to +75 °C. |
Mechanical and electrical specifications (PDF) · Solid-shaft drawing (PDF)
Mounting and fit
Fix the clamping flange to the machine register and connect the solid encoder shaft to the machine with an appropriate flexible coupling. Use the actual shaft diameter, exposed length and flat. Check that the coupling has room to flex within its alignment limits and cannot slide. Side load from a misaligned coupling can give intermittent motion and shorten bearing life. Confirm the correct fixing pattern from flange type 1/3 or the other drawing if the label specifies a different flange.
The 5883 hollow-shaft series uses a separate arrangement. Its clamp-ring torque does not describe the 5863 coupling. Record shaft and machine datum before removal. 5863 solid-shaft mating drawings (PDF)
Interface and measuring method
SSI is a clocked, point-to-point link. The receiver supplies differential CLOCK and the encoder shifts its position word back on differential DATA. The receiver interprets the singleturn and turn fields using the configured bit length and code. A live DATA signal can still decode to jumping or doubled counts if the Gray/binary selection or field alignment is wrong.
For the reference build, start from 13 singleturn plus 12 multiturn bits and verify framing in the receiver. Set the interval between transactions to allow a new sample. Kübler notes that clocking again within the monoflop window can repeat the same value.
Verified wiring
Use the cable row for interface codes 1/2 and termination A, and the connector drawing if yours has a plug. The M12 table applies only to the documented 8-pin type 5/6. Kübler’s connector figure shows the male mating face.
| Function | Cable colour | M23 12-pin | M12 8-pin |
|---|---|---|---|
| 0 V / +V | White / brown | 1 / 2 | 1 / 2 |
| CLOCK+ / CLOCK− | Green / yellow | 3 / 4 | 3 / 4 |
| DATA+ / DATA− | Gray / pink | 5 / 6 | 5 / 6 |
| SET / DIR | Blue / red | 7 / 8 | 7 / 8 |
| ERR status | Black | 9 | Not assigned on this 8-pin map |
| Shield | Screen | Housing | Housing |
Kübler specifies tying an unused SET input to encoder 0 V on this family. Verify the intended DIR state and keep unassigned cores isolated. Avoid operating SET during diagnosis until the original datum has been recorded and the machine procedure permits a reset. SET and direction behavior (PDF) · Wiring and mating views (PDF)
Cables inside the motor and at the machine
The reference code has a factory 3 m axial PVC open-end lead, ordered as .0030 on connection A. The data sheet lists special lengths and optional 8-pin M12 or 12-pin M23 builds. This is an externally mounted encoder with a receiver-side loom. For connector versions match the mating connector, shield and cable length and use the receiver drawing for the far end. A 12-pin cable wired for additional A/B or sense can differ from the base SSI variant. Factory cable order codes (PDF) · Variant cable and connector maps (PDF)
Fault checks
Isolate motion and supplies first. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
- Inspect. Check plug seating, foreign material, damaged pins, a loose coupling and a flexed or pinched cable. Verify that the machine actually turns the encoder shaft.
- Check the separate harness. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics.
- Measure the powered supply safely. With an approved breakout fitted while off, a qualified person can read DC from brown to white on the specified cable, or pins 2 to 1 on the documented base plug. Match 10–30 V versus 5 V to the encoder code. A valid supply alone leaves the CLOCK and DATA paths to check.
- Separate link, setup and position. No clock at the encoder points toward the receiver or cable. Clock without a valid reply calls for power, wiring polarity and encoder checks. Smooth but wrongly scaled or jumping position calls for Gray/binary, width, turn alignment, SET and DIR settings. Intermittency at high clock calls for inspecting the pairs, shield and receiver timing.
Motor and drive applications
A documented example receiver is Beckhoff EL5001, which has differential SSI clock/data and a configurable word length up to 32 bits. Its clock ceiling is 1 MHz and its encoder supply is 24 V from the power contacts. Confirm code and bit framing, and choose a compatible clock within both limits. A 5 V version needs its specified 5 V supply. Beckhoff EL5001 SSI technical data · EL500x setup manual (PDF)
Angle of alignment and commissioning
Commission the mechanical datum, count direction and SSI preset for the machine. Record the current value and receiver configuration before changing hardware. Check position through a full turn and across a turn boundary. Confirm home and permitted travel after any preset. This stand-alone encoder’s normal installation does not assign a motor commutation angle.
Drawings, pin maps and manuals
- Kübler Sendix 5863 / 5883 data sheet (PDF). Pages 1, 3–6 for exact order codes, SSI specifications, SET and DIR, connector mapping and solid-shaft dimensions.
- Beckhoff EL500x SSI sensor interface manual (PDF). Use the EL5001 wiring and commissioning sections for this receiver example.
- Kübler Sendix 5863 product page. Configure the exact flange, shaft and interface before ordering.