Share the full order code and revision, master or TwinCAT project, AL status, port indicators, raw position and parameter backup. Include the fitted shaft size and a photo of the restraint and M12 connectors. Use the enquiry form to share the details.
What specialist testing can show
A compatible EtherCAT master with the matching ESI can check identification, state changes, link diagnostics, process data and preset. Compare raw position against known rotation in a safe fixture. A separate encoder-side or receiver-side signal comparison helps localize a wiring problem. Exact Mitchell TI-5000JX and TI-3000JX support for this EtherCAT device was not verified. Kübler F58x8 startup and diagnostics (PDF)
Kübler Sendix F5888 EtherCAT Multiturn Encoder technical reference
Find your part number
Look for 8.F5888 on the encoder. The current ordering table uses two characters for flange and bore, B for the EtherCAT supply/interface option and N for three axial M12 connectors. B1 is the EtherCAT profile. The rows show configurations decoded from the published order-code table. Read the actual suffix and revision.
| Order code / pattern | Fit | Electrical / variant difference |
|---|---|---|
| 8.F5888.2BBN.B132 | Long spring element, IP67 flange option, 12 mm blind bore | B/N EtherCAT with separate power and two M12 data ports. |
| 8.F5888.4ABN.B132 | Ø65 mm stator coupling, IP67 flange option, 10 mm blind bore | Same B/N connection group. Different mechanical restraint and bore. |
| 8.F5868.32BN.B132-C | F5868 solid Ø10 × 20 mm shaft, IP67 clamping flange option | EtherCAT family, salt-spray-tested variant shown by Kübler. Separate shaft mounting. |
F5868/F5888 order-code tables (PDF) · Solid shaft F5868 model reference
Production and end-of-life status
Kübler publishes the current F5888 EtherCAT family, type code and ESI. Confirm orderability, revision and backwards compatibility against the full code. Earlier variants and other protocols require their own file and datasheet. Kübler family and downloads
Specifications
| Parameter | Manufacturer data |
|---|---|
| Measurement | Optical electronic multiturn, up to 19 singleturn bits and 24 multiturn bits. Read the actual master mapping and scaling. |
| Supply and current | 10–30 V DC, maximum 150 mA in the F58x8 technical table. |
| Connection | Three axial M12 connectors. A-coded power, D-coded link IN and link OUT. |
| Fit and speed | Blind bore up to 30 mm insertion in the published type-code table. 6000 rpm continuous and 9000 rpm short-term (10 min) in the technical table. |
| Environment | −40 to +80 °C working range. Check housing/shaft protection by flange and fit. |
Mounting and fit
Match bore, insertion depth, axial movement and the stator restraint to the fitted flange code. The blind bore clamps to the measured shaft while the spring element, coupling or torque stop holds the encoder body. Check that the shaft does not bottom out or load the bearing. Follow the correct dimension and fastener drawing. Record the shaft-to-machine position before removing the encoder. F5888 blind hollow shaft drawings and flange codes (PDF)
Interface and measuring method
The master uses an EtherCAT Slave Information (ESI) description and exchanges process data (PDOs) with the encoder. Parameters and diagnostics use the documented mailbox and object access. Link, INIT, PREOP, SAFEOP and OP indicate different stages. A healthy link alone does not confirm the correct PDO, preset or data type. Confirm the expected master state and raw counts over a known rotation. F58x8 state machine, objects and diagnostics (PDF) · ESI and product downloads
Verified wiring
Use this table only for interface B, connection N in the Kübler datasheet. Follow the manufacturer mating view and the labels for link IN and OUT.
| Pin | A-coded power | D-coded IN or OUT |
|---|---|---|
| 1 | +V, 10–30 V DC | TxD+ |
| 2 | Unassigned | RxD+ |
| 3 | 0 V | TxD− |
| 4 | Unassigned | RxD− |
Preserve the planned port order and seal unused sockets. Inspect both D-coded plugs and the separate power cord before swapping parts. Kübler terminal assignment and rear-view layout (PDF)
Cables inside the motor and at the machine
This is an external shaft encoder. Kübler lists 2 m open-ended cable 05.00.6031.4411.002M for the straight D-coded data connection and 05.00.6061.6211.002M for straight A-coded power. Choose a compatible completed assembly for the required master or downstream end and cable motion. Check pin mapping and shield with the exact accessory drawings. Kübler cable part numbers (PDF) · Accessory and ESI downloads
Fault checks
Plan the stop with the EtherCAT master and isolate machine and feedback power before changing cables or fit. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
- Record and inspect. Capture the device revision, state, AL status, link LEDs and whether other devices are affected. Check the M12 seats, shaft clamp and restraint while isolated.
- Check the cable separately. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. For the data link use an appropriate industrial Ethernet tester. Check the planned IN/OUT route.
- Check supply and configuration. A qualified technician can use an approved power breakout installed while off and measure pin 1 to pin 3 under load in the safe test state. Compare the ESI and startup parameters to the actual revision and master. Preserve the original mapping before any writes.
- Separate motion errors. Correct link with failed state transition suggests configuration or startup parameters. Stable raw counts but wrong engineering units suggests scaling or mapping. Position drift against the mechanical shaft calls for checking clamp and datum. Repeatable encoder errors on a verified service network warrant bench evaluation.
Motor and drive applications
Use on a compatible EtherCAT master for absolute speed and position feedback. Use Kübler's matching ESI and startup procedure for the exact revision. The F58x8 family has other fieldbus builds. Compare the B1 EtherCAT code and the actual device identity. Kübler F5888 EtherCAT downloads · Master integration (PDF)
Angle of alignment and commissioning
Set the mechanical shaft fit and verify direction, scale and datum. Capture the original offset and master settings before removal. Use the approved preset method in the exact manual with the axis stationary at a known reference. Verify the resulting position, a known movement and recovery after power cycling before releasing the axis. This is machine-axis commissioning. Kübler preset, scaling and saved configuration (PDF)
Drawings, pin maps and manuals
- Kübler F5868/F5888 EtherCAT data sheet (PDF). Ordering fields, dimensions, supply, cables and terminal assignments.
- Kübler F58x8 EtherCAT manual D000080287.0002 (PDF). State transitions, diagnostics, device mapping and preset.
- Kübler F5888 EtherCAT product downloads. Use the ESI and CAD files that match your full build and revision.
- Kübler F5868 EtherCAT. Different solid shaft family option.