Feedback diagnosis, Installation, Alignment. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A matched fixture can compare A/B phase order, index, and U/V/W sector transitions at controlled movement. Confirm TI-5677 and the actual TI-5000JX profile before applying power. Determine TI-3000JX run support separately for the full motor order.
Mitsubishi Electric OHE25K-6 ABZ and UVW Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is OHE25K-6. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
Manufacturer device order code
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| OHE25K-6 | Match the installed motor, coupling and end-cover drawing. | ABZ position/index and UVW commutation. Mitsubishi documents this suffix in its drive matrix. |
| OHE25K-85 | A separate suffix. The drive matrix gives no mechanical equivalence. | Same ABZ+UVW class. Confirm fitted harness and configuration before substitution. |
| OHE25K-ET | Separate encoder variant. | Appears in the spindle section of the same manual. Do not infer identical application or fit. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Measurement | Incremental A/B/Z with separate U/V/W commutation tracks, as classified by Mitsubishi. |
| Drive table | OHE25K-6 and -85 appear as compatible motor-end encoders under MDS-C1-N and MDS-A/B in the cited table. |
| Connector reference | Mitchell lists a 19-pin MS test lead for the HA OHE25K/OSE5K family. The exact motor bulkhead and key still govern. |
| Open specifications | Confirm resolution, supply range, receiver levels and mounting dimensions from the motor and feedback drawing. The cited compatibility table does not specify them. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Photograph the original encoder, rotor coupling, clamp orientation and harness before disturbing them. Look for witness marks, shaft play, an ovalled coupling or a cable trapped by the cover.
The drive manual identifies a signal type and drive pairing. Use the installed motor’s drawing for shaft dimensions, fastener torque and the disassembly sequence.
Interface and measuring method
A and B report motion and direction. Z provides a reference event. U, V and W give the drive the commutation sector independently of whether the count channels look healthy. A drive may detect movement while rejecting the starting sector.
Verified wiring
Trace the ABZ path and the UVW path separately on the motor/drive schematic. Use the correct drawing view at both ends and document any intended shield bonds.
An exact OHE25K-6 contact, colour and supply map for the installed motor remains open. Do not derive any of these from OHE25K-85, a plug shell or a high-speed serial Mitsubishi lead.
Cables inside the motor and at the machine
Mitchell’s public index lists TI-5677 for the Mitsubishi HA-series OHE25K/OSE5K ABZ/UVW family and 19-pin MS connection. This is a tester lead. Obtain the internal encoder-to-bulkhead and machine feedback loom numbers from the motor and drive labels.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No count or direction change | Isolate the harness and check the A/B paths, then verify receiver configuration and signal format under an approved test. |
| Good A/B but fault at starting | Check U/V/W sequencing against the exact motor documentation, alignment history and coupling slip. |
| Fault changes with cover fitted | Inspect strain relief, pin retention and internal cable routing. Compare disconnected harness results with the cover removed. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Start from the Mitsubishi motor nameplate and full MDS drive model. Mitsubishi’s MDS-C1/CH-N manual separates ABZ+UVW, ABZ plus low-speed serial, and high-speed serial motor feedback.
Angle of alignment and commissioning
Before removal document the original mechanical relationship, then use the exact motor procedure to establish the rotor-to-UVW reference. A stable count and index do not prove commutation timing.
Drawings, pin maps and manuals
- Main technical PDF. Section 1.1.4 identifies the OHE25K-6 and OHE25K-85 as ABZ+UVW motor-end encoders and scopes drive compatibility.
- Manufacturer reference. Mitsubishi CNC product and support index. The linked legacy manual documents the exact OHE25K-6 reference.
- Mitchell manufacturer cable index. The Mitsubishi section lists TI-5677 for the documented HA-series family.