Identify the fitted part
| Guide scope | MOOG Fastact K / F resolver — Motor application |
|---|---|
| Feedback identity | Record the fitted feedback maker and complete designation; the named motor family is not a sensor part number. |
| Manufacturer MPN / full suffix | Fastact K / F is the scoped family/designation. Match every additional character on the fitted label before ordering. |
| OEM service ID / motor order | Not established for a specific fitted unit. Record the full motor label, feedback option and any OEM service ID separately. |
| Interface | Resolver |
| Documented starting connection | PT00E 14-19 / PT06F8AG14-19 mating family; exact tester fixture to verify |
| Material distinction | TCG247 covers Fastact T/F; K/F is a separately documented motor family with its own connection and frame matrix. |
Specialist testing: connection before conclusion
| TI-5000JX bench scope | Angle and vector checks only after verifying winding pairs, excitation, resolver pole ratio and connector view. |
|---|---|
| Starting lead / fixture | PT00E 14-19 / PT06F8AG14-19 mating family; exact tester fixture to verify |
| Profile / module | J12 resolver setup; exact excitation, pole ratio and fixture from OEM drawing. |
| TI-3000JX motor-run scope | No complete motor-run approval established by this proposal. Verify motor poles, power/brake wiring, alignment, fixture and the installed TI-3000JX profile. |
The admission evidence is MOOG Motors — Fastact K/F, Type Code and Wiring Diagram (Resolver). Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.
Production and replacement status
Current production status, exact-order stock and an approved successor have not been confirmed in the cited evidence. Retain the installed label and ask for an exact-order check before selecting a replacement.
Specifications and interface
| Verified technical boundary | Match the K/F resolver connection and separate feedback faults from brake, fan and motor-power wiring. |
|---|---|
| Supply / output compatibility | Use the complete fitted label and its wiring drawing. No universal supply, receiver level or excitation is assigned to this family guide. |
| Exact dimensions, torque and pins | Use the scoped drawing or request it through the enquiry. Values from another suffix, connector view or motor revision are not substituted. |
A resolver uses an excited winding and two position-dependent secondary signals. The tester evaluates their relationship to obtain angle and vector. Excitation voltage, frequency, winding ratio and polarity belong to the exact resolver specification; resistance or a smoothly changing angle alone does not prove correct motor commutation.
Mechanical fit and retention
Photograph the incoming shaft/coupling position, locating seat, restraint, fasteners and cable exit before removal. Check accessible looseness, contamination, bearing roughness and signs of rubbing after isolation. Identify whether the assembly has its own bearings, a hollow-shaft clamp or a motor-retained sensor; the exact drawing controls that decision. Do not lever against a sensing disc or apply a torque from a similar-looking model.
The K/F article describes an eight-pole motor family and identifies F as the fan-cooled derivative. Its resolver signal connector is PT00E 14-19 PC-10 with PT06F8AG14-19S mating connection. The separate power-box types, fan and optional brake need their own drawings.
Wiring and connector boundaries
Map five boundaries separately: the sensor plug or PCB, internal motor loom, motor bulkhead, external machine cable and drive/tester end. Record connector gender, keying, contact numbering and whether the drawing shows mating or termination side. The documented Mitchell lead is a starting fixture, not a pin map for a handmade adapter. Keep power, temperature, brake, shield and feedback contacts identified individually.
Starting connection for this guide: PT00E 14-19 / PT06F8AG14-19 mating family; exact tester fixture to verify. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.
Internal loom and machine cables
No internal OEM harness number or universal extension has been verified for this exact fitted order. Obtain the motor assembly drawing and photograph both loom ends before sourcing it. A fixed installation cable and a cable-carrier extension may have different flex and shielding requirements. Do not convert the Mitchell test-lead number into an OEM replacement part number.
Practical fault checks
Isolation and measurement conditions
Secure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.
| Configuration-specific check | The K/F article describes an eight-pole motor family and identifies F as the fan-cooled derivative. Its resolver signal connector is PT00E 14-19 PC-10 with PT06F8AG14-19S mating connection. The separate power-box types, fan and optional brake need their own drawings. |
|---|---|
| Fault appears when the machine cable moves | With the system isolated and both ends disconnected, inspect flex points, connector engagement and repaired sections. Check end-to-end continuity and unintended shorts against the actual pin map, accounting for intentional shield bonds. |
| No feedback or intermittent loss at the drive | After label and fixture verification, have a qualified technician check the specified supply or excitation through an approved breakout. Compare at the source and load under the OEM procedure; never assume a voltage from the connector shell. |
| Angle moves but vector or phase is abnormal | Check winding identification, excitation and polarity before assessing the resolver itself. Record results at multiple positions using the applicable fixture; keep motor alignment assessment separate. |
Alignment, reference and memory
Record the incoming mechanical datum, direction and motor phase convention before disturbing the sensor. No numerical commutation angle or universal memory image is specified here. A motor-specific alignment requires the exact motor data, supported equipment setup and applicable OEM procedure. Preserve any recoverable offset, identity and parameter data before changes; establish hardware and data compatibility before a specialist transfer or write. Resolver electrical zero and the machine datum are different references. A replacement that reads angle correctly still needs the correct phase relationship to the motor.
Motor and drive applications
Fastact K / F resolver. TCG247 covers Fastact T/F; K/F is a separately documented motor family with its own connection and frame matrix.
A matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.
Drawings, manuals and evidence
- MOOG Motors — Fastact K/F, Type Code and Wiring Diagram (Resolver)
- Generic Resolvers — Named article section, model or attached table. See each proposal row for the exact scope and locator.
Exact OEM technical PDF remains to obtain. The Mitchell reference establishes only the documented device or motor/feedback connection; it does not fill missing ratings or pins.
Common questions
What should accompany a Fastact K / F resolver enquiry?
Send clear photographs of the motor and feedback labels, every suffix/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.
Can the listed Mitchell lead be used as a replacement machine cable?
The lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.
Does a successful feedback bench test prove that the motor can be run?
No complete motor-run approval established by this proposal. Verify motor poles, power/brake wiring, alignment, fixture and the installed TI-3000JX profile. A complete run assessment also checks motor power, brake, protection and mechanical conditions.
When does a site visit or send-in evaluation make sense?
A site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.
Request a scoped service evaluation