Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A qualified low-voltage test can compare supply and analogue output against known marker angles. Use the documented load and monitor return continuity. Check the sensor and the installed receiver separately. Exact Mitchell compatibility is unverified.
Novotechnik RFC-4801-636-211-202 Analogue Angle Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is RFC-4801-636-211-202. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| RFC-4801-636-211-202 | Slotted mounting version with external marker magnet and 1 m shielded cable. | Single-channel 360° example, 5 V supply and nominal 0.25–4.75 V ratiometric output. |
| RFC-4802 mounting option | Round-hole mounting version. Verify the exact full code. | Output and cable depend on the remaining option groups. |
| RFC-4801-636-171-431 | Separate teach-in ordering example in Novotechnik literature. | Check the complete teach-in and connection documentation. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Supply | 5 V nominal, 4.5–5.5 V supply option in the ordering table. |
| Output | 0.25–4.75 V ratiometric to supply at the nominal voltage. Single channel on the reference example. |
| Geometry | Separate rotating position marker and stationary sensor, slotted mount. Use the specific marker drawing for allowable spacing and offset. |
| Connection | Code 202 is a 1 m four-conductor screened cable. Match the one-channel assignment. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Fit the position marker to the moving shaft and locate the stationary sensor using the specified mounting drawing. Verify magnet type, offset and allowable gap. The external magnet orientation establishes the sensor's electrical reference region.
Interface and measuring method
The sensor converts the magnet angle to an analogue voltage. A ratiometric output changes with supply. Compare both signal and supply at the sensor and check whether the controller uses a matching reference. A healthy angle can be misread if the receiver is configured for another voltage or current option.
Verified wiring
Use the one-channel cable code 2xx column in the data sheet. These colours apply to the code 202 cable, with controller termination verified separately.
| Conductor | Function |
|---|---|
| Green | Ub +5 V nominal |
| White | Signal |
| Brown | GND |
| Yellow | Unassigned for this one-channel version |
Use the manufacturer's screen and receiver loading guidance. Avoid applying the 24 V variant's supply to this build.
Cables inside the motor and at the machine
Code 202 is the 1 m screened factory lead. Code 201 identifies the 0.5 m option in the same ordering table. Use the connector assignment for the exact lead type and obtain the machine-side assembly number from the wiring drawing.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Signal is pinned near one end | Check magnet type, orientation and gap. Verify supply and the signal common at the sensor. |
| Sensor voltage is sensible, PLC value is wrong | Compare input type, scale, common and ratiometric reference in the controller. |
| Output changes with movement of the harness | Isolate both ends and check the cable, strain relief and connector for intermittent faults. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use on a rotary linkage or shaft with a matching magnet and analogue receiver. Confirm installed stroke and allowed wrap region. The manufacturer ordering example identifies the reference build. Verify the actual label before applying the wiring.
Angle of alignment and commissioning
Use the position marker drawing to set the mechanical center and direction. Record the original angle and receiver scaling. Verify the output at known positions before restoring the machine datum or control limits.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Analogue ordering, output and wiring tables. Use the series 600 one-channel code 202 entry.