What specialist testing can show
TI-5000JX bench. On the documented connection, check movement, index where fitted and commutation separately.
TI-3000JX motor run. Confirm the full motor order, power lead, phase reference and supported TI-3000JX setup.
Starting lead. TI-5605 for the 18-contact male bayonet branch.
Parker / Compumotor SM Series Incremental ABZ/UVW Servo Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| SM Series ABZ/UVW | Scoped motor and test connection. Verify the fitted wiring. |
| SM160AE / SM160BE | Parker encoder-feedback examples with different motor windings. Use the complete suffix and drawing. |
| Other Compumotor families | Parker’s shared SM/SE reference contains several orders and motor characteristics. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Movement | Incremental A and B with reference Z on the named Mitchell branch. |
| Commutation | Separate U/V/W channels on that branch. |
| Connection | TI-5605, 18-contact male bayonet. |
Interface and measuring method
A and B indicate motion and direction, while the commutation channels indicate rotor sectors. Check both paths when the drive counts position but trips at enable.
Mounting and fit
Compare the SM frame and shaft drawing and the fitted rear feedback mount. Record cable exit and the incoming rotor reference before removing the assembly.
Wiring and connector scope
Use the full motor drawing to identify supply, return and the ABZ and UVW signals. Match the 18-contact view and distinguish encoder commutation conductors from motor phases.
Internal motor and machine cables
Record the motor pigtail and machine extension independently. Use the matching production drawing for repairs and TI-5605 for the scoped test.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Counts appear but the motor faults at enable | Check UVW state and phase reference. |
| Reference fails to home | Trace Z and check the configured index source. |
| Dropout near the plug | Check latch, contact retention and disconnected harness continuity. |
Angle of alignment and commissioning
Preserve direction, index and the commutation relationship to motor phases. Verify the exact phase convention and approved setup before adjustment.
Motor and drive applications
Parker Compumotor SM, documented 18-contact bayonet branch
Identify the encoder branch and separate missing position counts from a UVW commutation problem.
Drawings, pin maps and manuals
- Mitchell Test Cable Index by Manufacturer Support. Compumotor Support Part Numbers, TI-5605 lists SM alongside N0, BE and SE
- Parker Compumotor SM and SE motor catalogue. Supplementary reference for the stated model or setup.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.