Encoder and resolver technical library
Parker SMH / SMB 170 / 35 Nm Incremental / Commutation Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment
Parker SMH / SMB 170 / 35 Nm with Incremental / Commutation is covered in this technical guide. Use it to identify the fitted assembly, compare the documented feedback branches, preserve incoming alignment and readable data, and prepare a scoped UAE site visit or send-in evaluation for installation, repair and alignment.
Identification · Testing · Specifications · Mechanical fit · Wiring · Alignment · Documents · Service enquiry
Identify the fitted motor and feedback
| Identification item | Scoped information |
|---|---|
| Manufacturer / grouped base | Parker SMH / SMB 170 / 35 Nm |
| Reference | TCG1644; SpareFaber service-guide reference, not an OEM part number |
| Frame / family | 170 |
| Catalogue M0 / stall reference | 35 Nm; match the selected catalogue row, conditions and complete fitted order |
| Cooling / assembly | Natural-ventilated SMH/SMB catalogue base; identify any Servofan kit separately |
| Motor-data source | Parker SMH/SMB catalogue, pp.6–7, 12, 18 |
| Mechanical source | p.11, resolver/no-brake reference dimensions |
| Coverage boundary | incremental and commutation branches; base identifier omits complete speed/winding/shaft/brake/factory suffixes |
Photograph the complete motor plate, serial, encoder label, feedback connector face and drive nameplate before disturbing the assembly. Record the actual brake, shaft, mounting, cooling, thermal sensor and speed/winding fields. A1 / A2 / A3 / C4 — fitted incremental/Hall branch is the documented branch grouping used here; it is not a full factory order or an authorization to exchange devices.
This guide concerns incremental quadrature and commutation, with no retained absolute ST/MT claim. Identify index width/phase and actual line-driver/commutation outputs from the fitted encoder. Preserve machine homing, drive offsets and shaft reference before changing the holder, cable or device.
Specialist feedback testing
Device-level test scope: Use the installed Generic Incremental Encoder/compatible fitted-device selection for the actual quadrature and commutation branch. Mitchell's reference separates A/B/index counting from commutation line-state evaluation. Verify supply, differential levels, PPR versus edge-count convention and motor pole count before interpreting displayed mechanical/electrical angle. Correct pulse counting alone does not prove correct commutation sequence or rotor alignment.
Record the tester hardware, lead/module, software version, selected feedback type and actual fitted label with the report. First record the incoming fitted-device configuration and relevant position/signal observations. Preserve supported readable identity and data before any write. A changing count or angle alone does not prove correct mechanical installation, signal quality, commutation sequence or drive configuration.
| Test record | What the observation establishes |
|---|---|
| Label and setup match | The selected device, electrical interface and supply/excitation match the identified branch |
| Slow manual movement | Direction, continuity, cyclic behaviour and the applicable index/turn transition can be compared |
| A/B/index and commutation | Record differential levels, pulse count, index and commutation sequence separately |
| Independent signal checks | A valid A/B count does not prove correct index or commutation outputs |
| Before/after report | Incoming configuration and each approved service change remain traceable |
Motor-run scope: TI-5000JX feedback evaluation and TI-3000JX motor-run approval are separate decisions. Establish full motor parameters, pole count, phase convention, fixture/load, brake handling and speed/current limits before a run. A supported feedback protocol does not approve a run profile for this complete motor. No universal minimum firmware or exact motor-bulkhead adapter is asserted here.
Motor data and incremental/commutation reference
| Parameter | Documented incremental branch | Scope |
|---|---|---|
| Available frame-170 options | A1 / A2 / A3 / C4 | B3 and D3 are not listed for frame 170 |
| Pulses per revolution | A1 2,000; A2 2,048; A3 4,096; C4 5,000 | Keep PPR separate from quadrature edge counts |
| Feedback supply | 5 V DC ±5%; table current 200 mA | Verify complete fitted label and cable |
| Output | Differential line driver | Check A/B/index true and complement channels |
| Commutation | Hall/commutation for 8-pole motor branch | Confirm actual motor and signal sequence |
| Retained absolute revolutions | Not supplied by the incremental interface | Homing/reference belongs to the machine application |
The catalogue torque reference for this grouped base is 35 Nm. It is used for identification and priority, not as momentary peak torque or a guaranteed rating for every speed/winding/cooling condition. The selected stall reference follows the catalogue's 65 K-rise conditions. Keep the 60 Nm and 35 Nm bases, speed/winding and thermal/mounting conditions distinct.
Incremental A/B counting and commutation outputs do not establish a retained absolute position or a multiturn encoder. Pulses per revolution, quadrature edge counts, index and commutation pole cycles must be recorded separately.
This guide concerns incremental quadrature and commutation, with no retained absolute ST/MT claim. Identify index width/phase and actual line-driver/commutation outputs from the fitted encoder. Preserve machine homing, drive offsets and shaft reference before changing the holder, cable or device.
Mechanical fit, cooling and removal reference
The published resolver/no-brake length reference is 306 mm for this 35 Nm class. An incremental feedback holder, brake, inertia option or fan can alter the envelope; compare the actual complete-order drawing.
| Fit item | Record and compare |
|---|---|
| Flange / pilot / mounting holes | Use the exact drawing and mounting version, including connector clearance |
| Shaft / key / coupler | Record actual dimensions, insertion depth and machine reference before removal |
| Encoder mounting | Identify holder, coupling, fasteners and mechanical reference from the fitted device |
| Brake and fan | Identify options and added envelope; verify their separate electrical circuits |
| Seals / coolant / enclosure | Match the actual cooling arrangement and ingress-protection build |
Mark the incoming relationship between motor housing, feedback body, shaft and machine reference. Support the assembly without loading the encoder shaft or bearing through an improvised puller. Use the documented removal and assembly method for the fitted device; no unreviewed taper, fastening torque, air gap or insertion force is supplied by this grouped guide.
Mechanical drawings to compare: p.11, resolver/no-brake reference dimensions. Connector orientation and holder variants can change practical clearance even where the nominal frame is the same. A similar-looking donor motor does not establish identical shaft, brake or encoder fit.
Wiring and connector scope
Use the frame-170 A1/A2/A3/C4 incremental/Hall connector drawing and exact fitted order. A pulse count and a commutation pole count are different setup inputs. Trace A/B/Z and the fitted commutation outputs separately; a correct A/B count does not establish the startup commutation route.
| Circuit / branch | Identification boundary |
|---|---|
| A / B differential pairs | Verify true/complement outputs, phase sequence and direction |
| Index / Z | Check the fitted pulse and its relationship to the shaft reference |
| Commutation / Hall outputs | Identify the actual signal pairs and documented 8-pole motor sequence |
| Supply / 0 V | Use the fitted 5 V ±5% device requirement and verified endpoint drawing |
| Shield and motor circuits | Keep encoder/commutation lines separate from phases, brake, thermal and fan circuits |
Read connector drawings in their stated contact-side view and verify numbering, keyway, male/female contacts and shell position. Check continuity with both ends isolated before applying feedback power. Photograph and label any repaired or custom loom so the test report identifies the actual route used.
Keep motor phase conductors, brake supply, fan supply, protective earth, thermal circuits, encoder supply/return and signal pairs distinct. Do not infer a pinout from wire colour, a shared connector shell, another manufacturer's motor or an electrically different feedback option. If a diagram caption and an order table disagree, resolve the actual fitted branch before energizing it.
Test leads, internal loom and machine cable
| Connection layer | What must be established |
|---|---|
| Direct encoder plug | Exact device connector and compatible bench lead; not automatically a motor-bulkhead connection |
| Motor internal loom | Continuity, shielding, strain relief and any changes made during earlier repairs |
| Motor feedback / hybrid bulkhead | Correct socket, contact view, branch and separate power/brake/thermal circuits |
| Machine cable | Both endpoint pinouts, length/routing, drag-chain damage and shield termination |
| Drive / tester end | Correct installed selection, supply module and interface-specific lead |
A device that reads correctly with a direct plug but fails through the motor can point to the internal loom or bulkhead route. A device that works at the motor but fails through the machine harness requires an endpoint-by-endpoint cable check. Document which layer was bypassed; do not report a complete motor or machine harness as proven from a direct encoder test.
Preserve A/B/index differential pairs, commutation wiring, supply and return. Check true/complement levels and the actual index/commutation route; a cable that passes A/B count alone can still have a commutation fault.
No complete machine-cable part number or universal lead is assigned to every configuration in this guide. Select or document the cable only after the complete motor/encoder labels and both connector endpoints are known.
Diagnostic symptoms and useful comparisons
| Reported symptom | Evidence to collect before changing parts |
|---|---|
| No count / missing index | Fitted supply, A/B/Z levels, PPR/edge-count convention and isolated cable continuity |
| Position changes but drive faults remain | Status codes, configuration, motor-data interpretation and phase/alignment relationship |
| Intermittent or noisy behaviour | Connector contact, strain/routing, shield integrity and signal quality through each cable layer |
| Incorrect direction or scaling | Recorded device direction, selected protocol/word format and drive scaling; do not rewrite offsets to hide it |
| Machine reference / scaling unexpected | Pulse versus edge count, direction, index/homing and drive reference retention |
| Fault appeared after removal | Original reference marks, mechanical holder/shaft relationship, supported offsets and before/after reports |
Compare one identified path at a time: direct encoder, internal loom, motor bulkhead, then machine cable/drive. Retain the original symptom, fault codes and setup with each result. An isolated cable fault, an unsupported test selection and a damaged encoder can present a similar initial symptom.
Check A/B counting, index and commutation sequence as separate results. Use the actual motor pole count and count convention; a position count does not establish electrical alignment.
Alignment, offsets and memory preservation
Capture the incoming shaft/machine reference, device label, drive offsets, direction and the relevant angle/index/commutation relationship before removal. Preserve controller configuration and the homing/reference method with a report identifying the fitted device, fixture, lead and selected test setup.
After mechanical work, check the fitted encoder's mounting and signal quality before interpreting an angle. A wrong cable/selection or an unstable mechanical fit can make an otherwise valid offset appear incorrect. Do not copy an angle, memory image or motor profile from another motor merely because its frame or protocol matches.
The resolver/incremental interface does not establish serial encoder memory or a retained multiturn turn counter. Preserve available controller offsets, reference/homing data and mechanical alignment through the application-specific workflow. Do not apply an absolute-encoder memory image to this device.
If the original relationship or data is unavailable, define a motor-specific recovery method from documented motor/feedback information and the installed test system. This guide does not prescribe a universal lock-up angle, firmware threshold, phase convention or replacement memory file. Record the before/after evidence and the exact change performed.
Service scope, replacement and availability
This is a technical-guide/service listing for Parker SMH / SMB 170 / 35 Nm, not a claim that a complete motor, encoder, brake, fan or cable is held in stock. Parts and service scope follow review of the full fitted labels, connector photos, fault report and required operating conditions.
A replacement decision must compare interface, absolute/analogue behaviour, supply, mounting, shaft/holder, connector route, thermal/brake options, supported motor data and drive compatibility. A motor-base match alone does not establish a drop-in replacement. Catalogue inclusion does not prove current production, exact-order availability, turnaround or certification.
Provide clear label and connector photographs plus the reported symptom and any previous repair changes for a scoped UAE site visit or send-in evaluation. The service quotation can then identify the assessment, repair, alignment or installation work and any parts that require confirmation.
Applications and practical service enquiries
The selected 170 frame/family and 35 Nm catalogue reference place this guide in the identified motor range; they do not rate a new machine duty. Typical enquiries concern feedback faults, connector/loom repair, motor replacement identification, reinstallation after mechanical work and preservation of existing alignment/data.
- Compare the exact motor and feedback branch during a repair intake.
- Document a cable-versus-encoder investigation before replacing an otherwise serviceable assembly.
- Prepare an installation or reinstallation visit with complete labels, drive details and machine reference.
- Assess an identified replacement against the actual shaft, cooling, brake, connector and data requirements.
Related interface guides for the same base: Resolver — TCG1643. Each retains its own electrical scope.
Request installation, repair or alignment assessment and include reference TCG1644.
Drawings, manuals and evidence
- Parker SMH/SMB catalogue PDE2815TCUK. Parker SMH/SMB catalogue, pp.6–7, 12, 18. Mechanical reference: p.11, resolver/no-brake reference dimensions.
- Mitchell generic incremental quadrature/commutation test reference. Confirm counts, line levels and motor pole data.
- Parker SMH/SMB feedback specifications p.12, encoder/frame association table and connector drawings pp.13–16, order definitions p.18. A1/A2/A3/C4 apply to frame 170; B3/D3 are not listed for that frame.
These references support the scoped family and documented options. The complete fitted order and actual device revision determine the final wiring, envelope, software selection and service method. Keep the source edition/page, nameplate photos and measured setup with the report so a later technician can reproduce the identification.
The cover is a branded service illustration with concise headings. It is not an OEM dimensional drawing or proof of the exact motor/encoder installed in a machine.
Frequently asked questions
Is this a complete factory motor order?
No. Parker SMH / SMB 170 / 35 Nm is a guide grouping. Match all winding/speed, shaft, mounting, cooling, brake, feedback and custom-order fields on the actual plates.
Is this an absolute ST/MT encoder?
This guide covers incremental A/B/index and commutation. Homing/reference and retained machine position depend on the actual controller/application.
Can I use another motor's cable or test selection?
Only after the actual device, supply, complete endpoint wiring and installed support are established. A shared shell, frame or protocol name is not enough.
Does feedback testing prove a motor-run setup?
No. Exact motor parameters, fixture/load, brake and phase/alignment conventions require their own motor-specific run-test approval.
Can the original alignment and data be preserved?
Capture available incoming identity, mechanical reference, supported angles/offsets and readable data before removal or writes. Recovery after missing data requires a defined motor-specific method.
How do I request service?
Send full motor and encoder labels, connector photographs, drive details, fault symptoms and previous repair changes with TCG1644. Installation, repair, alignment and site/send-in scope follow identification.
Enquire about this encoder or resolver
Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.