Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A specialist can use the setup indication and approved differential receiver to compare A/B amplitude and phase, reference and limits over travel. Verify any Mitchell fixture for this exact head and cable. The device is a linear readhead and does not use a motor-run fixture.
Renishaw RGH22A 1 Vpp Optical Linear Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is RGH22A. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| RGH22A · RGH22A15L00A order-key example | A is analog dual limit. 15 means 1.5 m and L denotes the analog 15-way D-type. | 00A is standard in the order key. Confirm the complete combination against the fitted label. |
| RGH22B | Related single-limit analog head. Check termination code. | Compare limit/setup output assignment before moving the cable. |
| RGH22D | Separate digital variant in the same family. | Check its output and connector drawing independently. |
Production and end-of-life status
Renishaw lists RGH22 as obsolete and no longer orderable. Its migration page gives candidate families. Verify their scale, mounting, output and reference requirements against the machine.
Specifications
| Parameter | Value and scope |
|---|---|
| Measuring method | Non-contact optical readhead on the compatible RGS20 scale system. |
| Process outputs | Differential 1 Vpp analog A and B for RGH22A/B. RGH22A has two limit outputs. |
| Order key example | A / 15 / L / 00A gives dual limits, 1.5 m cable, analog 15-way D-type and standard option. Confirm the actual label. |
| Reference and setup | Use the applicable reference mark and limit actuator arrangements. RGH22A uses contact 7 on L termination for Vq. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Clean and inspect the scale as permitted by the installation guide. Check ride height, yaw, pitch and roll using the specified datum faces and setup process. A change over the travel can indicate bracket deflection, damaged scale or a changing gap. Confirm alignment throughout travel before setting the datum.
Interface and measuring method
Movement over the scale generates two sinusoidal tracks. The downstream interpolator uses their phase for position. The reference mark provides a repeatable location and the limit outputs identify configured end positions. Diagnose signal strength, reference and limits as separate paths.
Verified wiring
Use the Renishaw connection table for analog RGH22A/B and the termination code on the label. The L connector is a 15-way analog D-type. For RGH22A the table assigns the clear wire on L contact 7 to Vq. Keep this separate from the RGH22B external setup use of that connection. Match the signal and shield table to the exact head and controller.
Cables inside the motor and at the machine
The 15 code describes the integral cable length. L is the analog D-type termination and has its own pin view. For a replacement head or extension, identify the installed connector, cable length, analog channel pairs, reference and both limits. Use an extension and receiver input that satisfy the Renishaw cable specifications.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Signal LED changes at one area of travel | Check local scale contamination or damage, ride height and bracket movement. |
| A/B signal is healthy and reference will not repeat | Inspect the reference actuator and setup, then verify the controller input and relevant conductor. |
| One limit fails after a replacement | Confirm dual-limit A type and the exact L pin assignment. Check Vq and actuator position separately. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use RGH22A with the documented RGS20 scale, reference and limit accessories and a compatible analog receiver. Check whether the original controller handles its limit and reference signals in the same connector.
For a later optical linear family, compare the installed scale and interface. TONiC T1030-15A guide.
Angle of alignment and commissioning
This is scale-to-readhead alignment and machine datum commissioning. Adjust the head using the Renishaw setup procedure, confirm signal quality along the axis and validate reference and limits. For a retrofit, confirm geometry and electronics before moving the datum.
Drawings, pin maps and manuals
- Main technical PDF. Renishaw RGH22 data sheet. Read the analog connections and ordering sections together.
- Manufacturer reference. Renishaw's current legacy-product reference, including RGH22 lifecycle and migration leads.
- Renishaw RGH22 RGS20 installation guide. Scale fit, readhead setup and analog connections.