What specialist testing can show
TI-5000JX bench. Verify the fitted EnDat part and separate live feedback from the original motor-memory data.
TI-3000JX motor run. Confirm the exact motor, certification and approved setup before assigning a run test.
Starting lead. TI-5079 on the documented direct-to-encoder connection.
Bosch Rexroth MKE B / D EnDat Servo Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| MKE B | Singleturn EnDat in the Rexroth motor type key. |
| MKE D | Multiturn EnDat, with 4,096 revolutions in the cited type key. |
| MKE G / K and N / P | Separate digital resolver or legacy Indramat feedback branches. Mitchell lists their own hardware and memory selections. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| B / D analogue reference | 2,048 periods in the cited Rexroth type key. Confirm the fitted encoder and drive wiring. |
| Bench connection | TI-5079 and TI-5101, as listed for B/D by Mitchell. |
| Motor memory | Mitchell lists BRI_EnDat Memory Test for the scoped codes. |
Interface and measuring method
EnDat provides position data and access to encoder information. Read communication, position and motor-memory results separately. The turn field matters when choosing the D configuration or restoring the axis reference.
Mounting and fit
Use the original Rexroth parts and service documentation for the exact MKE order and protection marking. Inspection and repair of a certified assembly must follow the approved process. Record the received fit and reference.
Wiring and connector scope
Match the documented direct test plug only to the fitted encoder connector. Use the OEM motor bulkhead wiring and drive cable as separate references. Check the connector and housing certification before cable work.
Internal motor and machine cables
Match the original motor and drive cable by complete order and approval. Obtain the internal harness number through the fitted assembly documentation. Use TI-5079 as the matched bench connection.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| D encoder reports position but turn data is missing | Check full type code, turn-field setup and whether a B unit was fitted. |
| Serial link good, motor data fails validation | Check saved original data and BRI_EnDat selection. |
| Fault changes when the external cable moves | Trace the documented isolated harness, connector locking and shielding. |
Angle of alignment and commissioning
Capture the original motor data, direction and physical reference. Use the Rexroth procedure and applicable certified service route to verify any replacement and motor commissioning.
Motor and drive applications
MKE with verified B or D encoder option
Identify the B/D route, save the original motor data and follow the OEM scope for certified assemblies.
Related SpareFaber guides
Drawings, pin maps and manuals
- Bosch/Rexroth/Indramat MKE Motors. MKE motor model breakdown, feedback codes B and D
- Bosch Rexroth MKE project planning manual R911297663. Supplementary reference for the stated model or setup.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.