What specialist testing can show
TI-5000JX bench. Mitchell documents TI-5747 and legacy HIPERFACE memory checks. Verify the fitted variant and software version.
TI-3000JX motor run. Verify the exact MS2N motor, supported branch and approved fixture separately before powered operation.
Starting lead. TI-5747 on the documented legacy HIPERFACE branch.
Bosch Rexroth MS2N Legacy HIPERFACE Servo Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| MS2N legacy HIPERFACE | Mitchell documents the SKS/SKM and SEK/SEL branches. Use the full order and fitted label to identify the exact encoder. |
| MS2N with ACUROlink | Separate feedback protocol and fixture. Verify the order code before applying the legacy HIPERFACE guide. |
| TI-5747 | Mitchell’s documented lead for the legacy motor-side connection. Verify the connector on the actual motor. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Feedback | Classic HIPERFACE on the named legacy MS2N branch. Determine singleturn or multiturn from the fitted label. |
| Diagnostic lead | TI-5747 for the matching feedback connector. TI-3025 is the power lead reference in the article. |
| Stored data | Mitchell reports MS2N motor alignment in the Rexroth memory report on the supported legacy branch. |
Interface and measuring method
Serial position and OEM data share the classic HIPERFACE communications path. Check analogue motion signals separately. Verify the memory report and actual commutation before treating an apparently valid read as a complete repair check.
Mounting and fit
Use the full MS2N motor and fitted encoder drawings. Record shaft engagement, stator restraint and cable routing before disturbing the assembly.
Wiring and connector scope
Verify the legacy HIPERFACE plug against TI-5747. Use the fitted connector drawing for supply, return, data, analogue pairs and shielding. Confirm the exact protocol before connecting.
Internal motor and machine cables
Use the motor and drive orders for the machine cable. Identify the internal encoder loom from the fitted assembly. Keep TI-5747 and the separate power cable distinct.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| No reply through TI-5747 | Confirm legacy HIPERFACE and the fitted connector before testing the cable. |
| Memory test shows warnings | Use the applicable Mitchell software guidance and preserve the raw data. Compare the exact device and drive. |
| Drive alarms after replacement | Check the full encoder suffix, OEM memory and the verified commutation reference. |
Angle of alignment and commissioning
Save the incoming memory and measured reference before replacement. Mitchell describes retrieving the stored angle from the saved file on affected software versions. Verify the actual motor and current software before writing data.
Motor and drive applications
Rexroth MS2N with legacy HIPERFACE
Capture complete MS2N order, exact encoder suffix, stored data and approved internal loom.
Related SpareFaber guides
Drawings, pin maps and manuals
- Rexroth MS2N series motors. Legacy HIPERFACE and TI-5747 memory procedure
- Rexroth MS2N product catalogue R999000462. Mitchell-linked OEM product and model-code reference.
- Mitchell TI-5747 test lead sheet. Use with the verified MS2N legacy feedback connection.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.