Site visit or send-in evaluation
Provide the full AMT code, shaft diameter, motor pole count and OEM alignment reference, drive model and configured PPR. Save the old setup and send photos of the base, mating cable and shaft end. Use the enquiry form to share the details.
What specialist testing can show
Same Sky's AMT Viewpoint can read configuration and support digital zero setup with the proper interface. A compatible scope/counter and safely driven fixture can verify A/B/Z and U/V/W. Compare the outputs and phasing with the motor data. Mitchell's generic incremental/commutation concepts are relevant. Exact AMT313S-V cables and TI-5000JX/TI-3000JX support need confirmation. AMT Viewpoint settings and diagnostics · AMT31 wiring and alignment (PDF)
Same Sky AMT313S-V Capacitive Commutation Encoder technical reference
Find your part number
Read the complete AMT313S-V kit code. AMT313 is the axial (right-angle) connector format, S the single-ended CMOS output selection and -V the configurable kit. The code alone does not tell you the programmed resolution, motor poles or zero. Read the original settings where possible.
| Kit | Output version | Connector form |
|---|---|---|
| AMT313S-V | Single-ended A/B/Z and U/V/W | Axial, 14 contacts. Main pin table below. |
| AMT313Q-V | Differential A/B/Z, single-ended U/V/W | Axial, 14 contacts. Complement contacts are used. |
| AMT312S-V | Single-ended A/B/Z and U/V/W | Radial, 17-contact connector. Serial pin order differs. |
| AMT312D-V | Differential quadrature and commutation | Radial, 17 contacts. Use the D output table. |
Same Sky ordering fields and connector tables (PDF)
Production and end-of-life status
Same Sky publishes AMT313S-V as an AMT31 kit. Confirm production or supply for the full code and revision with Same Sky. Older CUI Devices documentation may carry the same series name. Manufacturer AMT313S-V record · Current AMT31 series datasheet (PDF)
Specifications
| Parameter | Documented value |
|---|---|
| Technology | Modular capacitive incremental. A/B quadrature, one Z index per turn, and U/V/W commutation. |
| Power | 4.5–5.5 V DC. 16 mA typical unloaded for the series. S outputs are single-ended CMOS. |
| Resolution and poles | Discrete programmable 48–4096 PPR choices and 2, 4, 6, 8, 10, 12 or 20 motor poles. Use the resolution/speed table. |
| Shaft sleeves | 2, 3, 3.175, 4, 4.76, 5, 6, 6.35 and 8 mm in the kit. |
| Mechanics | Axial 14-pin format. Standard and wide base options, shaft adapter and assembly tools are shown in the kit drawing. |
Mounting and fit
Measure the motor shaft and choose the matching sleeve. The manufacturer's tools position the sleeve/shaft adapter and center the base to set the working geometry. Use the illustrated assembly order, compatible base and correct motor mounting features. Confirm the top cover is fully seated and the shaft spins without rubbing while the motor is secured. Repeated removal can fatigue the clips. Keep the motor housing clean and protect the exposed modular assembly. AMT31-V sleeve selection and assembly procedure (PDF)
Interface and measuring method
A/B quadrature measures relative motion and Z supplies a once-per-revolution index. U/V/W indicate motor electrical sectors used by a compatible drive for brushless commutation. The separate programming UART lets the technician read or change setup. A good count does not confirm that U/V/W transitions match the motor or that the zero is correct. Verify logic type before matching a receiver. Quadrature, commutation and UART interface (PDF)
Verified wiring
This table uses the AMT313S column and the 14-contact axial connector drawing. Use the numbered mating view. A U, V or W encoder output is a logic signal and must be kept separate from motor power.
| Contact | Function |
|---|---|
| 1 / 2 | RX_ENC+ / TX_ENC+ for the programming UART |
| 3 / 5 / 7 | U / W / V commutation logic outputs |
| 4 / 6 | Ground / +5 V encoder supply |
| 8 / 10 / 12 | B / A / Z single-ended outputs |
| 9 / 11 / 13 | Unused on S. The Q option uses them for B−, A−, Z−. |
| 14 | MCLRB programming reset. Follow Same Sky's setup instructions. |
Cables inside the motor and at the machine
Same Sky lists the shielded 14-pin AMT-14C-1-036 cable for AMT313. The 14-contact mating housing in the encoder drawing is Samtec ISDF-07-D-L. Verify the open-end conductors against the current cable document and the OEM bulkhead map. A complete motor-side connector kit or bulkhead cable number depends on the motor builder. Same Sky AMT313 compatible cable record · Mating connector and pin drawings (PDF)
Fault checks
Isolate the motor, drive and 5 V supply before connector or hub work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
- Inspect. Check sleeve size, shaft adapter grip, base position, seated clips and harness strain. Confirm the connector label and housing before mating. Capture motor and encoder settings before opening the motor.
- Isolated lead checks. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Identify the 14 pins by their proper mating view. Inspect pushed-back contacts and debris.
- Check supply and pulses. A qualified technician can use an approved breakout installed while off and check pin 6 relative to 4 under load with motion controlled. Use a suitable receiver or scope for A/B/Z and U/V/W. Compare signals on both ends and against the configured pole and PPR values.
- Interpret. No outputs can come from supply or harness faults. Good A/B/Z with a rough start after refit calls for checking U/V/W order, pole count and zero. Inconsistent counts after handling call for checking hub grip and shaft movement.
Motor and drive applications
Use with a compatible BLDC motor and drive accepting single-ended incremental and commutation signals. Confirm the motor pole count and phase definition, encoder mechanical fit, voltage, receiver and permitted speed for the chosen PPR. The Q/D versions have different line drivers. AMT31 configuration and signal options (PDF)
Angle of alignment and commissioning
Read and record the installed resolution, poles and commutation settings before removal. Same Sky's alignment command stores the U transition and Z index at the current position. Establish that position from the motor OEM's documented procedure and verify actual phase relationship after assembly. A qualified specialist should use the specified fixture, approved limits and AMT Viewpoint or the supported AMT-OTZ-1 setup. Preserve the customer's verified data. A generic motor phase or angle is unsuitable for unknown windings. AMT31 digital zero and motor-specific alignment procedure (PDF) · AMT Viewpoint
Drawings, pin maps and manuals
- Same Sky AMT31-V kit technical datasheet (PDF). Kit and assembly, AMT313S pinout, available resolutions and alignment.
- Same Sky AMT31 series datasheet (PDF). Current family documentation and drawings.
- Same Sky AMT-14C-1-036 cable. Compatible AMT313 cable and its drawing.
- Same Sky AMT Viewpoint. Read and adjust approved encoder parameters.