Site visit or send-in evaluation
Encoder identification, Approved installation assessment. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
After removal under the site procedure, a specialist can scope the exact model for bench checks in a suitable safe location. Use the approved circuit and documentation. Site testing and restoration of the intrinsic safety loop require authorized personnel.
Sensata BEI H25 01062-049 Intrinsically Safe Incremental Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is 01062-049. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
Manufacturer device order code
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| 01062-049 · H25D-SS-1024-AB-9V/OC-SCS18-EX | H25 shaft encoder. Match the SCS18 connection and exact mechanical drawing. | 1,024 P/R A/B incremental. 9V/OC and EX specify the exact electrical and intrinsically safe version. |
| H25 or H25D with another suffix | Similar housing may have another shaft, mounting or connection. | Check the complete order and approval. H25 family identity alone does not establish hazardous-area use. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Item and model | 01062-049. Sensata maps it to H25D-SS-1024-AB-9V/OC-SCS18-EX. |
| Incremental data | 1,024 pulses per revolution, A/B in the specified order code. |
| Output | 9V/OC order option, open collector. Use the approval drawing and barrier requirements for the actual circuit. |
| Mechanical | Match the exact shaft, flange, coupling and connection to the installed drawing. Sensata’s family images are illustrative. |
| Approval | Confirm the approval and revision on the unit’s marking and use the matching control drawing and plant safety documentation. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Use the exact assembly drawing for the shaft, pilot, coupling and entry. Check alignment and restraint with the machine secured. Keep the installation within the documented conditions for the device and associated equipment.
Interface and measuring method
The A/B transitions give direction and incremental motion. The receiver and approved barrier circuit must support the exact open-collector option. Compare the encoder’s marked configuration with the engineered loop.
Verified wiring
Use the certified loop drawing and exact model connection schedule before assigning conductors or selecting a supply. Treat the approval and barrier as part of the circuit. Do not extrapolate from a general H25 wiring table.
Cables inside the motor and at the machine
Identify the exact field cable, barrier, shield and earth scheme from the plant drawing. Check compatibility through the responsible hazardous-area engineer before any cable or connector change.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
For a hazardous-area installation, follow the site’s permit and isolation procedure. Use only authorized test equipment and methods for that area. Perform internal inspection or measurements through the responsible qualified technician.
| Observation | What to verify |
|---|---|
| No count at the controller | Record approved diagnostics at the safe-area receiver and barrier. Compare the documented loop configuration and alarm history. |
| Direction fault after replacement | Compare exact nameplates, mechanical orientation and approved A/B assignments. Verify the replacement and approval documents. |
| Connector damage or unreadable approval marking | Keep the affected installation out of service according to the site procedure. Get the exact unit identified and inspected by authorized personnel. |
Motor and drive applications
Use this guide for identification and service scoping in installations that specifically call for 01062-049. The installation approval depends on the marked equipment, compatible barrier and site documentation.
Angle of alignment and commissioning
Verify the mechanical coupling and count direction within the approved service procedure. Restore the documented machine zero and complete the plant inspection before resuming operation.
Drawings, pin maps and manuals
- Main technical PDF. Sensata H25 family data and ordering options. Use the exact 01062-049 record and label with the applicable approval and installation documents.
- Manufacturer reference. Match the exact order code or the identified motor option.