Site visit or send-in evaluation
Share the label, master and PLC model, port diagnostics, IODD revision, raw position and machine readout. Include the previous parameter set and a photo of the coupling if available. Use the enquiry form to share the details.
What specialist testing can show
Use a compatible IO-Link master and the correct IODD to check communication, identity, position, speed and parameters. Compare raw values against a known shaft movement and an independent reference. Keep a bench master isolated from the production configuration. Exact Mitchell TI-5000JX and TI-3000JX coverage for this IO-Link build was not verified. SICK IO-Link Basic operating instructions (PDF)
SICK AHS36B-S3QC004096 IO-Link Absolute Encoder technical reference
Find your part number
Look for AHS36B-S3QC004096 and 1093084. The exact build is a Basic singleturn unit with 4096 maximum steps per revolution, 6 mm solid shaft, face-mount flange and four-contact M12 male. AHS and AHM distinguish singleturn and multiturn in this IO-Link family. Check the full code because the same housing family has more than one interface.
| Model and part number | Position and fit | Connection / behavior |
|---|---|---|
| AHS36B-S3QC004096 · 1093084 | Basic singleturn 12-bit, Ø6 mm solid shaft × 12 mm, face flange | M12 four-contact. Pin 2 unused. |
| AHS36B-S5QC004096 · 1100069 | Basic singleturn 12-bit, Ø8 mm solid shaft × 12 mm, face flange | M12 four-contact. Different shaft fit. |
| AHS36A-S3QC016384 · 1101573 | Advanced singleturn 14-bit, Ø6 mm × 12 mm, face flange | M12 four-contact. Advanced pin 2 can have a configured function. |
| AHM36B-S1QC012x12 · 1092009 | Basic 12-bit singleturn plus 12-bit multiturn, Ø6 mm servo flange | M12 four-contact. Match the data model and flange. |
1093084 exact data (PDF) · SICK IO-Link model and part-number tables (PDF)
Production and end-of-life status
SICK publishes an exact 1093084 data sheet. Confirm current lifecycle, orderability and successor against that part number with SICK. The AHS/AHM36 family also contains builds with different interfaces and mechanics. SICK 1093084 datasheet (PDF)
Specifications
| Parameter | Value |
|---|---|
| Position | Singleturn, 4096 positions/revolution maximum. Configurable steps per revolution. |
| Communication | IO-Link 1.1 COM3, 230.4 kbaud, cycle time ≤3.2 ms according to the exact sheet. Position and speed process data. |
| Supply and consumption | 18–30 V DC and ≤1.5 W on the exact SICK datasheet. |
| Mount and speed | Ø6 mm solid shaft with flat, 12 mm length, face-mount flange, up to 9000 rpm. 40 N radial and 20 N axial maximum shaft loading. |
| Environment | IP65. Operating −20 to +70 °C without condensation. |
Mounting and fit
Match the face-mount pilot, screw pattern, shaft diameter and insertion length to the exact dimensional drawing. Use a suitable separate coupling so the encoder is driven without binding or imposing side load. Under isolation check for a loose setscrew, misalignment and a connector forced by cable routing. Confirm the machine bracket and coupling dimensions before selecting a replacement. 1093084 face-mount dimensional drawing (PDF) · SICK mounting guidance (PDF)
Interface and measuring method
The magnetic encoder sends digital process data over the C/Q conductor to an IO-Link master port. The master handles parameter access and presents data to the PLC. The IODD describes the device and parameter layout. A valid link with incorrect position can be a counting direction, resolution, preset or PLC mapping issue. Compare master raw position and speed with the PLC value before changing the encoder. One revolution wraps in singleturn mode. IO-Link process data and parameter sections (PDF) · IO-Link IODD Finder
Verified wiring
| Pin | Reference lead colour | Function |
|---|---|---|
| 1 | Brown | L+ encoder supply (18–30 V DC on exact datasheet) |
| 2 | White | Unused for Basic |
| 3 | Blue | L−, 0 V supply return |
| 4 | Black | C/Q, IO-Link communication |
Use the numbered mating view on the datasheet. Compare actual harness continuity against that view. Advanced and Inox tables have distinct pin functions and applicable ratings. 1093084 Basic assignment (PDF)
Cables inside the motor and at the machine
This external unit connects directly to the machine IO-Link master. For the factory M12 male, SICK lists YF2A14-020UB3M2A14 (2096000, 2 m) and YF2A14-050UB3M2A14 (2096001, 5 m), A-coded female-to-male PUR cordsets. DOS-1204-G (6007302) is the listed field-wireable female with screw terminals. Verify the master end, environmental rating and machine routing. SICK 1093084 accessory table (PDF)
Fault checks
Secure and isolate the axis and feedback supply before mechanical or cable work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
- Read and record. Note the port status, device ID, raw position and whether the fault began after a change. Under isolation, check the coupling, M12 key and seating, pins, moisture, damaged locking threads and strain relief.
- Test the cordset. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Verify the link conductor on contact 4 and the two supply contacts. For a simple passive cordset, compare the master and sensor ends pin by pin.
- Check supply and port. A qualified technician can use an approved breakout installed while isolated, then check L+ to L− under load with motion secured under the site procedure. Verify that the master port is in IO-Link mode and has the matching IODD and data layout.
- Separate faults. If the link and raw word are stable while machine position is wrong, compare the mechanical coupling, preset and PLC scaling. If the raw word freezes during a controlled movement, check coupling first, then compare with a known-good compatible cordset and master port. Preserve the production setup before substitution.
Motor and drive applications
The SICK product information lists absolute position measurement for packaging, handling and machine building. In a PLC system, select a compatible IO-Link master, import the correct IODD and verify process data width and decoding on the master and PLC. CANopen or SSI versions require their own documentation. SICK application and type-code reference (PDF) · IO-Link Basic installation (PDF)
Angle of alignment and commissioning
Commission this external position encoder by checking coupling, count direction, steps per turn and machine datum. Preserve the device parameters and current displayed position before replacing it. Apply the approved preset through the IO-Link parameter interface for this Basic model with the axis stationary at its known reference. Verify one full turn and wrap at controlled speed before handing back the machine. Basic parameter and pin functions (PDF) · SICK preset and configuration sections (PDF)
Drawings, pin maps and manuals
- SICK AHS36B-S3QC004096 1093084 (PDF). Exact specifications, pin numbers, mounting dimensions and cordsets.
- SICK AHS/AHM36 IO-Link Basic operating instructions (PDF). Installation, IODD, settings, diagnostics and preset.
- SICK AHS/AHM36 IO-Link product information (PDF). Variants and differences between Basic and Advanced.
- IO-Link IODD Finder. Look up the matching device and revision.