Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Use a compatible SSI master or the machine diagnostics to compare the decoded position and status along known travel. Use the matching SICK parameter tool when service access is required. Verify exact Mitchell support and any bench measuring element fixture before testing.
SICK KH53 KHK53-AXR00038 1030048 SSI Linear Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is KHK53-AXR00038. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| KHK53-AXR00038 · 1030048 | KH53 head for up to 38 m, with fixed 1.5 m twelve-wire cable. | 24-bit Gray SSI, separate RS-422 service interface. |
| KHK53-AXU00038 · 1030051 | Related 38 m head with a 10 m fixed cable. | SSI. Compare the exact cable routing and device configuration. |
| KHK53-AXB00038 · 1030052 | Separate M23 male 12-pin device connector build. | SSI. Use the connector-specific drawing rather than a flying-lead assumption. |
| KHK53-PXF00038 · 1036163 | Related 38 m PROFIBUS head with separate M12 connections. | PROFIBUS. It needs a different interface and commissioning setup. |
Production and end-of-life status
SICK publishes the exact 1030048 sheet and KH53 ordering information. Confirm production and replacement options for this order with SICK.
Specifications
| Parameter | Value and scope |
|---|---|
| Position | 0–38 m with correctly selected measuring elements. Resolution 0.1 mm, repeatability 0.3 mm. |
| Supply | 10–32 V DC, listed current 250 mA and initialization time 2 s. |
| Output | 24-bit Gray SSI. RS-422 service lines are separate and parameter interface is off by default. |
| Connection | 1.5 m factory fixed cable, twelve-wire classification in the data sheet. |
| Fit and environment | Use the N and Y attachment geometry. IP66 and −20 to +60 °C operating range. Precision conditions in the sheet are tighter than the maximum position envelope. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Fit the head and coded measuring elements in the documented orientation and sequence. Use the 38 m system mounting gauge KHM53-XXX00038 (1030057) where prescribed. Align the brackets through full travel and keep magnetizable parts clear per the exact attachment drawing. Check element joins and the cable carrier where position faults repeat.
The exact sheet separates nominal geometry, operating tolerance and accuracy conditions. Use the system drawing for element lengths, start positions and permitted gaps.
Interface and measuring method
The head senses the coded measuring elements along the route. The PLC clocks absolute Gray-coded position over SSI. The separate asynchronous RS-422 service path is used for configuration where enabled. A healthy service connection does not prove that the PLC is clocking or decoding the SSI word correctly.
Verified wiring
The exact 1030048 PDF combines the SSI connector reference view and cable colours. Use the colour column below for the fixed cable. The numbered M23 view is for the connector form, so verify your actual harness and receiving side independently.
| Path | Factory lead colour |
|---|---|
| Supply / GND | Red / blue |
| SSI Data+ / Data− | White / brown |
| SSI Clock+ / Clock− | Yellow / violet |
| RS-422 service Rx+ / Rx− | Grey / green |
| RS-422 service Tx+ / Tx− | Pink / black |
| Unused | Orange is unassigned in the exact sheet. |
Keep the service pairs separate from SSI and follow SICK's shield and cable instructions.
Cables inside the motor and at the machine
The 1.5 m fixed lead belongs to 1030048. The 3 m, 5 m and 10 m factory leads are separate readhead orders 1030049, 1030050 and 1030051. The 1030052 M23 head needs its own mating cable. Match the machine terminal drawing and shielding before ordering an extension.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No SSI word | Confirm supply and initialization time, then check controller clock and both SSI pairs. |
| Word valid but travel wrong | Check Gray decoding, scaling and the measuring-element arrangement and order. |
| FF FF FE hex at a repeatable position | SICK identifies this error when the head leaves the elements or the permitted traversing speed is exceeded. Check actual position, speed and geometry. |
| Fault near an element joint | Check the mounting gauge alignment, bracket movement, element sequence and nearby magnetic material. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use this guide for the exact 38 m SSI head and the matching KH53 measuring elements. SICK lists KHT53-XXX00038 (1030055) and KHU53-XXX00038 (1030056) in the system guide. Confirm the coded or configurable element type before installation.
Angle of alignment and commissioning
Check the head-to-element position along travel and verify the prescribed measuring-element sequence. Record controller position and datum before removal. Validate the SSI word, direction and absolute reference after fitting. The adjustment is a linear measuring system setup.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- SICK exact wiring and M23 reference view. Use fixed lead colours for 1030048.
- SICK KH53 ordering and installation information. Match the head, scale elements and mounting gauge.
- SICK 1030052 M23 variant. Separate head and connector configuration.