Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
An approved HIPERFACE setup can read the parameter channel and check both analog tracks. Mitchell lists classic HIPERFACE paths for other SICK models. Confirm the exact 1037378 mating lead, module, firmware and TI-5000JX selection. Verify motor-run support independently.
SICK SEK37-HFB0-K02 1037378 HIPERFACE Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is SEK37-HFB0-K02. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| SEK37-HFB0-K02 · 1037378 | Tapered rotor and radial 8-pin male connection. | Single-turn classic HIPERFACE. Use the SEK37 parameter selection. |
| SEL37 family | Check the complete type and mating geometry. | Related family with multiturn feedback. Read actual item ID before comparing. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Incremental tracks | 16 sine/cosine periods per revolution. |
| Absolute reading | 512 steps within one turn over the RS-485 parameter channel per 1037378 datasheet. |
| Power | 7 to 12 V DC, 8 V recommended. Current below 50 mA without load. |
| Mechanical | Tapered shaft. Maximum operating speed 12,000 rpm for the listed unit. |
| Connector | 8-pin radial male, with separate analog references and RS-485 data pair. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
The tapered rotor mates with the corresponding motor shaft. The stator connection holds the housing while the rotor turns. Compare the taper, shoulder location and housing seat with the SICK dimension drawing. The radial plug needs room for the cable exit without rubbing the end cap.
On the isolated assembly, check that the rotor fastening and stator clamp are seated and that the housing has not shifted. Use the motor and encoder instructions for screw, torque and gap details.
Interface and measuring method
The drive reads initial absolute position and parameters over RS-485. It interpolates the two analog process tracks for motion feedback. Measure SIN against REFSIN and COS against REFCOS with the specified instrument and termination. Checking against the shell can mask a reference conductor fault.
Verified wiring
Follow the exact sheet’s connector diagram to orient the radial plug. Wire colors vary by harness. The datasheet distinguishes the 0 V return from the housing.
| Contact or group | Function |
|---|---|
| 1 / 6 | US supply / GND return |
| 2 / 3 | SIN / REFSIN |
| 4 / 5 | COS / REFCOS |
| 7 / 8 | RS-485 Data+ / Data− |
Cables inside the motor and at the machine
Trace the radial 8-pin plug to the OEM motor outlet and then to the drive. Match the housing latch and outlet orientation, the two analog references and the data pair. Obtain the actual PCB-to-bulkhead loom by motor order. A SICK cable described for a different 8-pin model is only a lead until the mating housing and pin order match.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Drive reads identification but faults when turning | Check both analog signal-reference pairs and the mechanical seat. Inspect flex points in the motor loom. |
| Analog tracks are present and the drive cannot read ID | Check RS-485 data pair, configured parameter channel and loaded supply. |
| Fault began after fitting a related SICK unit | Compare the full item, taper, connector exit and single/multiturn selection. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
This model is for a motor and drive using classic HIPERFACE. Match the motor order, drive feedback input and item 1037378 together. A HIPERFACE DSL drive uses a different feedback path.
Compare the older classic HIPERFACE motor family by its own code. SKM36 technical guide.
Angle of alignment and commissioning
Read and retain the original motor reference and applicable data before moving the encoder. The datasheet documents a parameter channel, while the motor OEM defines the actual alignment and any data restoration. Use the procedure for the exact motor and drive, and verify position feedback before returning the machine to operation.
Drawings, pin maps and manuals
- Main technical PDF. SICK 1037378 datasheet. See the electrical data, dimensional drawing, pin assignment and signal diagrams.
- Mitchell classic HIPERFACE examples. SKS/SKM and SRS/SRM fixtures are scoped to those families.