Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Mitchell documents the TI-5000JX HIPERFACE family workflow for serial response and status. Confirm the exact S21 profile, adapter, supply and fixture first. Check motor-running compatibility and alignment separately.
SICK SRS50-HZA0-S21 HIPERFACE Motor Feedback Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is SRS50-HZA0-S21. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| SRS50-HZA0-S21 · 1037395 | Customized hollow shaft and rubber support. Radial 8-contact male connector. | Singleturn HIPERFACE, 32768 steps, 1024 sine/cosine periods. |
| SRS50-HAA0-K22 · 1037060 | Standard reference in the S21 datasheet. Verify its shaft and support separately. | Use the exact connection and rating sheet for this build. |
| SRS50S-HZA0-S21 · 1051813 | The extra S identifies the separately documented SRS/SRM50-S device. | Verify the intended safety application and all approved components separately. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Position | 32768 steps, one distinguishable revolution, 1024 sine/cosine periods per turn. |
| Supply and interface | 7–12 V DC, 8 V DC recommended. HIPERFACE parameter link and sine/cosine process data. |
| Connector | Radial 8-contact male connector. Use the encoder face drawing on the exact datasheet. |
| Fit and motion | Customized hollow shaft and rubber support. The exact drawing and permitted movement values govern the installation. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Use the S21 drawing to identify the custom shaft seat, support position and radial cable space. Inspect the stator support and shaft retention with the motor isolated. Check movement against the specified static and dynamic limits. Use the motor manufacturer’s hardware and fitting procedure.
Interface and measuring method
HIPERFACE gives the drive absolute position through the bidirectional RS-485 parameter link. The separate SIN and COS channels carry incremental motion. Each analogue signal has a reference conductor. A drive can report an absolute read error while the sine and cosine paths still produce signals.
Verified wiring
| Pins | Function |
|---|---|
| 1 / 2 | Supply US / GND |
| 3 / 7 | REFSIN / +SIN |
| 4 / 8 | REFCOS / +COS |
| 5 / 6 | Data+ / Data− |
Orient by the connector diagram in the exact sheet. SICK shows alternative wire colours for some data leads. Match contacts by the documented face and isolated continuity. Use the motor drawing for the bulkhead and shield.
Cables inside the motor and at the machine
Specify the S21 radial plug and exact motor-side and drive-side terminations when sourcing a loom. Confirm the motor order, installed cable code, retention and shield connection. The 8-contact encoder layout establishes the encoder end only.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Drive reports a HIPERFACE communication alarm | Check supply, radial plug condition and both serial conductors. Read encoder status using the documented drive or tester. |
| Position initializes and then becomes unstable | Compare SIN against REFSIN and COS against REFCOS at the encoder and receiver. |
| Repeatable mechanical-angle fault | Inspect custom bore seating, support condition and harness strain before replacing the encoder. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
The S21 is a custom SRS50 configuration. Identify the fitted motor and drive from their own labels. Check any singleturn, multiturn or safety requirement against the actual OEM configuration.
Angle of alignment and commissioning
Record the existing encoder data and machine settings before removal when supported. Restore motor-specific data only to a verified compatible encoder for the same motor. The approved motor and drive procedure sets the commutation reference.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Exact item 1037395 data sheet. Contains the custom shaft drawing, 8-contact map, signal direction and HIPERFACE status list.
- SRS50S variant sheet. Separate item 1051813.
- Mitchell HIPERFACE training chapter. Bench communication and fault indication. Match the adapter to the specific encoder.