What specialist testing can show
TI-5000JX bench. Compare motor-side and direct paths to isolate a ribbon or encoder fault. Verify the actual SCM70 configuration.
TI-3000JX motor run. Match the complete MDD/MHD order, profile and saved motor memory before a run test.
Starting lead. TI-5021 motor-side or TI-5076 direct on the applicable documented legacy connection.
SICK Stegmann SCM70 Indramat MDD / MHD Multiturn Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| SCM70 on the documented MDD/MHD legacy branch | Multiturn member of the SICK family. Confirm the motor order, ribbon and fitted serial profile. |
| SCM70-HSV0-K01 · 1034059 | SICK catalogue example for tapered integration, with short lead and connector. Confirm the fitted order. |
| SCM70-HLV0-K01 | SICK hollow-shaft integration example. Compare the shaft and housing before sourcing. |
| SCS70 | Singleturn companion with its own reported type. |
Production and end-of-life status
SICK identifies SCS/SCM 60/70 as an older family with different Stegmann and SICK code styles. Confirm exact orderability or approved replacement from the motor documentation.
Specifications
| Parameter | Verified scope |
|---|---|
| SICK family position | 512 sine/cosine periods, 16,384 positions per turn and 4,096 turns for the standard SCM70 family. Verify the Indramat variant. |
| Serial functions | The SICK family catalogue describes a HIPERFACE parameter channel. Use the motor-specific Indramat profile where fitted. |
| Connections | TI-5021 is listed for 12-contact M23 Indramat digital MDD/MHD. Verify the applicable TI-5076 direct connection and exact ribbon. |
Interface and measuring method
The SICK platform provides analogue tracks and a parameter channel. For an OEM Indramat assembly, verify the actual data profile and motor memory independently. A catalogued SICK part number by itself does not establish Indramat compatibility.
Mounting and fit
Mitchell’s legacy section shows the taper and key arrangement on applicable units. Use the exact removal drawing and approved tooling. Inspect the ribbon and connector with the assembly supported and record the original position.
Wiring and connector scope
Trace the motor-side M23 and the internal ribbon as separate paths. Read the SICK figure for the exact connector and compare the OEM schematic before assuming that a generic HIPERFACE map applies.
Internal motor and machine cables
Check the ribbon for folds, damage, connector engagement and solder-joint movement using the approved inspection process. Record the ribbon revision and distinguish it from the machine extension.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Motor-side reads intermittently, direct check is stable | Inspect the internal ribbon and bulkhead before condemning the encoder. |
| Singleturn value present but turn field is missing | Confirm SCM versus SCS and check the fitted profile. |
| Offset after replacement | Compare taper and key seating and the original saved motor reference. |
Angle of alignment and commissioning
Save the received motor memory and mechanical reference before disturbing the shaft or data. Follow the Indramat procedure for the complete motor order and correct SICK variant.
Motor and drive applications
Indramat MDD/MHD with documented SCM70 assembly
Distinguish the fitted SCM70 multiturn unit and preserve original memory and alignment before disturbing the ribbon cable.
Related SpareFaber guides
Drawings, pin maps and manuals
- Indramat (Rexroth, Bosch) MDD/MHD Encoder Removal. MDD/MHD removal, SCS/SCM70 assembly and motor-side/direct encoder test notes
- SICK SCS/SCM 60/70 technical catalogue. Integration and attachment orders, drawings, signal and connector options.
- Indramat Digital Motors, Serial Encoders and Resolvers. Reference for the fitted feedback or motor option.
- SICK legacy type-code reference. Stegmann and SICK label differences for the older 512-period family.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.