What specialist testing can show
TI-5000JX bench. Compare serial position, turn count and incremental signal quality using the matched connector.
TI-3000JX motor run. Mitchell lists SRM50/60 in the relevant OEM run tables. Verify the actual motor option.
Starting lead. TI-5069 on the matched SRS/SRM direct connector. Module TI-5104 on the verified classic HIPERFACE fixture.
SICK Stegmann SRM60 HIPERFACE Multiturn Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| SRM60-HEA0-K01 · 1034157 | Manufacturer table shows tapered shaft, connector and 512-byte EEPROM. |
| SRM60-HEA0-K02 · 1034158 | Tapered shaft and connector with 2,048-byte EEPROM. Confirm fitted memory requirements before changing the variant. |
| SRM60-HEV0-K01 · 1034160 | Tapered-shaft cable exit and 512-byte EEPROM. The K02 cable option is 1034161. |
| Plug-in shaft family | The separate 7 mm plug-in shaft versions are shown with their own order references and outline. |
| SRS60 | Singleturn branch with the same general interface family. Compare the actual label before replacing. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Absolute position | 32,768 steps per turn and up to 4,096 measurable turns for SRM60 in the OEM tables. |
| Analogue process channels | 1,024 sine/cosine periods per mechanical turn. Tester decoded counts use a different convention. |
| Supply | 7–12 V DC for the documented connector drawing. |
| Mount and memory | The OEM document separates tapered shaft and 7 mm plug-in shaft, plug and cable exits, and 512- or 2,048-byte memory options. |
Interface and measuring method
Classic HIPERFACE has analogue sine/cosine process channels and an RS-485 parameter channel. Compare the serial position and turn count with the separate analogue signals to determine which path is affected.
Mounting and fit
Use the OEM shaft drawing for taper or 7 mm plug-in fit and the rubber support envelope. Compare insertion, seating, antirotation and axial clearance. Check the same variant drawing before applying fastening values.
Wiring and connector scope
The table below applies to the tapered-shaft connector in the SRS/SRM60 OEM document, direction of view B. Use the stated view before numbering. The motor bulkhead can use a different map.
| Contact or circuit | Documented scope |
|---|---|
| Pins 1 and 2 | Supply and ground. |
| Pins 3 and 7 | REFSIN and +SIN. |
| Pins 4 and 8 | REFCOS and +COS. |
| Pins 5 and 6 | Serial Data+ and Data−. |
Internal motor and machine cables
Use the fitted motor order for the encoder-to-motor loom and the motor-to-drive harness. Match each view and retain the screen connection arrangement shown in the OEM document. TI-5069 refers to the compatible direct test lead.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Serial position reads and analogue signals are noisy | Check reference and process pairs, screen continuity and seating on the correct fixture. |
| Singleturn angle reads but turn behavior is wrong | Confirm the SRM rather than SRS label and verify the drive’s turn configuration. |
| Drive rejects a fitted spare | Compare exact memory size, old data and the mechanical and electrical reference. |
Angle of alignment and commissioning
Capture the motor-specific memory, incoming shaft reference and direction. Compare turn behavior and commutation after fitting using the motor procedure. Use the exact connector and memory variant for a replacement.
Motor and drive applications
SRM60-equipped servomotors, verify fitted suffix
Give the SRM60 model its own fitted-shaft, connector and multiturn checks.
Related SpareFaber guides
Drawings, pin maps and manuals
- SICK Stegmann Hiperface Serial Encoders. SRS50/60 singleturn and SRM50/60 multiturn identification
- Allen Bradley (Reliance, Electrocraft) Motors. Supplementary reference for the stated model or setup.
- SICK Stegmann SRS/SRM 50 and 60 technical information. Manufacturer document with the tapered and 7 mm plug-in drawings, view B pin table and exact order numbers.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.