What specialist testing can show
TI-5000JX bench. Check digital position and ID on the identified EnDat option. Verify any analogue tracks from the fitted drawing.
TI-3000JX motor run. Confirm the full motor order, power lead, phase reference and supported TI-3000JX setup.
Starting lead. TI-5629 on the scoped 12-contact M23.
STÖBER ED / EK Heidenhain EnDat M23 Servo Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| ED / EK with EnDat | Singleturn or multiturn absolute options appear in the STÖBER catalogue. Read the actual encoder ID. |
| ED / EK with resolver | Optional two-pole resolver in the cited motor catalogue. Use its own circuit drawing. |
| EZ EnDat M17 | Related STÖBER family with the separate TI-5713 route. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Motor-side connection | TI-5629, 12-contact M23, for the scoped ED/EK branch. |
| Feedback options | The manufacturer catalogue distinguishes singleturn and multiturn EnDat and optional resolver. |
| Digital and analogue signals | Confirm the encoder order and connector table before applying supply or checking any analogue tracks. |
Interface and measuring method
EnDat returns absolute position digitally. A multiturn encoder also reports turns. Compare the receiver setup and actual fitted feedback before treating a missing turn field as a fault.
Mounting and fit
Use the ED/EK frame drawing and the full HEIDENHAIN ID for the rear assembly. Photograph the seating and cable route and retain the mechanical reference before removal.
Wiring and connector scope
Use the ED/EK wiring tables for the fitted feedback option and motor mating face. Match clock, data, supply and any analogue circuits to the verified pin view.
Internal motor and machine cables
Separate the M23 motor bulkhead, the internal encoder cable and the machine extension when tracing a fault. TI-5629 identifies the tester connection.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| M23 plugs together but no reply | Check the fitted pin map and feedback option. |
| Serial position good but analogue alarm | Confirm the encoder supports the expected tracks and trace their pairs. |
| Position scale or turn range changed after replacement | Compare the full encoder ID and controller selection. |
Angle of alignment and commissioning
Record direction, motor reference and turn position where applicable. Verify reference and feedback selection through the approved STÖBER commissioning process.
Motor and drive applications
STÖBER ED and EK, documented 12-contact M23 branch
Match the older M23 loom and feedback option before exchanging a motor or test cable.
Drawings, pin maps and manuals
- Mitchell Test Cable Index by Manufacturer Support. STÖBER row TI-5629
- STÖBER SMS ED and EK synchronous servo motors catalogue. Supplementary reference for the stated model or setup.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.